My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1714 S Greenville St - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Greenville St
>
1714 S Greenville St
>
1714 S Greenville St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:00:11 PM
Creation date
6/1/2025 11:59:52 AM
Metadata
Fields
Template:
Plan
Permit Number
20178382
101113418
Full Address
1714 S Greenville St
Document Relationships
20178382 - Permit
(Permit - Plan)
Path:
\Building\Permits\G\Greenville St\1714 S Greenville St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET NAME <br />SHEET NUMBER <br />PV-4 <br />PROJECT NAME <br />FE <br />L <br />I <br />P <br />E <br /> <br />G <br />O <br />N <br />Z <br />A <br />L <br />E <br />Z <br />1 <br />7 <br />1 <br />4 <br />G <br />R <br />E <br />E <br />N <br />V <br />I <br />L <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />4 <br />0 <br />8 <br />0 <br />6 <br />2 <br />2 <br />5 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br /> <br />J <br />O <br />S <br />E <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATEDESCRIPTION <br />VERSION <br />UR09/17/2022 INITIAL RELEASE <br />ELECTRICAL LINE <br />DIAGRAM WITH <br />CALCULATION <br />ELECTRICAL LINE DIAGRAM WITH CALCULATION <br />SCALE: NTS1 <br />AMBIENT TEMPERTURE SPECIFICATIONS <br />RECORD <br />LOW TEMP <br />AMBIENT TEMP <br />(HIGH TEMP 2%) <br />CONDUIT <br />HEIGHT <br />CONDUCTOR <br />TEMPERATURE <br />RATE (ON <br />ROOF) <br />CONDUCTOR <br />TEMPERATURE <br />RATE (OFF <br />ROOF) <br />2°31° IN ATTIC 90°75° <br />INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL # QUANTITY NOMINAL OUTPUT <br />VOLTAGE <br />NOMINAL OUTPUT <br />CURRENT <br />SOLAREDGE SE5000H-US 01 240 VAC 21A <br />C <br />SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / MODEL # VMP IMP VOC ISC <br />TEMPERATURE <br />COEFFICIENT <br />OF Voc <br /># OF MODULES <br />HANWHA Q CELLS Q.PEAK DUO <br />BLK ML-G10.A+(400W)37.13 10.77 45.30 11.14 -0.27%/°C 17 <br />MODULE DIMENSION 74.0" L x 41.1" W x 1.26" D <br />(E) 100A MAIN <br />SERVICE PANEL <br />WITH (E) 100A <br />MAIN BREAKER <br />(TOP FED) <br />L <br />EXISTING <br />GROUNDING <br />SYSTEM <br />SCE INSTALLED <br />GENERATION METER ADAPTOR <br />100A <br />BI-DIRECTIONAL <br />UTILITY METER <br />1-PHASE, 3-W, <br />120V/240V, 60Hz <br />E <br />D <br />SYSTEM SIZE:- (17 x 400)W = 6.80 kWDC <br />SYSTEM SIZE:- (17 X 376.55 X 0.99) / 1000 = 6.337 CEC kW AC <br />WIRE TAG CONDUIT WIRE QTY WIRE <br />GAUGE WIRE TYPE TEMP. <br />RATING <br />WIRE <br />AMPACITY (A) <br />TEMP. <br />DERATE <br />CONDUIT FILL <br />DERATE <br />DERATED <br />AMPACITY <br />(A) <br />NOC (A) <br />DESIGN <br />CURRENT <br />(A) <br />GROUND <br />SIZE <br />GROUND <br />WIRE TYPE <br />A OPEN AIR 4 10 AWG PV-WIRE 90°C 40 0.96 0.8 38.40 15 15 06 AWG BARE CU <br />GND <br />B 3/4" EMT 4 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 15 15 10 AWG THWN-2 <br />C 3/4" EMT 3 10 AWG THWN 75°C 35 0.94 1.0 32.90 21 21 10 AWG THWN <br />D 3/4" LIQUID <br />TIGHT 3 6 AWG THWN 75°C 65 0.94 1.0 61.10 21 21 - - <br />E 3/4" LIQUID <br />TIGHT - ------- - -8 AWG THWN <br />#2 #1#09 <br />DC <br />AC <br />#2 #1#08 <br />09 MODULES CONNECTED IN STRING #1 <br />08 MODULES CONNECTED IN STRING #2 <br />(N) SOLAREDGE SE5000H-US (240V) <br />OUTPUT: 240 VAC,21A <br />99% CEC WEIGHTED EFFICIENCY <br />NEMA 3R, UL LISTED, INTERNAL GFDI <br />WITH INTEGRATED DC DISCONNECT <br />G <br />(N) JUNCTION BOX <br />A <br />B <br />SOLAREDGE POWER OPTIMIZER S440 <br />RATED DC INPUT POWER - 440 WATTS <br />MAXIMUM INPUT VOLTAGE - 60 VDC <br />MPPT RANGE - 8 TO 60 VDC <br />MAXIMUM INPUT CURRENT - 14.50 ADC <br />MAXIMUM OUTPUT CURRENT - 15 ADC STRING <br />LIMITATIONS - 8 TO 25 OPTIMIZERS, <br />5700 WATTS STC PER STRING MAXIMUM <br />SOLAREDGE OPTIMIZERS HAVE INTEGRATED <br />RAPID SHUT DOWN <br />NOTE: FUSED DISCONNECT SHALL BE LOCATED NOT MORE <br />THAN 2-3 FT. FROM THE GMA PER SCE REQUIREMENT <br />G <br />(N) AC DISCONNECT <br />60A FUSED,WITH <br />30A FUSES,240 VAC <br />30A FUSES <br />EXISTING <br />GROUNDING <br />SYSTEM <br />SEPARATE GEC FROM ARRAY TO NEW <br />GROUND ROD MUST BOND TO WATER <br />GROUND <br />1714 S Greenville <br />St02/10/23
The URL can be used to link to this page
Your browser does not support the video tag.