Laserfiche WebLink
CAUTION ! <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />SHEET NAME <br />SHEET NUMBER <br />PV-5 <br />PROJECT NAME <br />FE <br />L <br />I <br />P <br />E <br /> <br />G <br />O <br />N <br />Z <br />A <br />L <br />E <br />Z <br />1 <br />7 <br />1 <br />4 <br />G <br />R <br />E <br />E <br />N <br />V <br />I <br />L <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />4 <br />0 <br />8 <br />0 <br />6 <br />2 <br />2 <br />5 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br /> <br />J <br />O <br />S <br />E <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATE DESCRIPTION <br />VERSION <br />UR09/17/2022 INITIAL RELEASE <br />WARNING LABELS & <br />PLACARD <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />! <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />IF GROUND FAULT IS INDICATED <br />ALL NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />LABEL LOCATION: <br />SERVICE PANEL IF SUM OF BREAKERS EXCEEDS <br />PANEL RATING <br />(PER CODE: [CEC 705.12(B)(2)(3)(B)]) <br />LABEL LOCATION: <br />AC & DC DISCONNECT AND SUB PANEL <br />(PER CODE: CEC 690.13(B)) <br />WARNING:PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION: <br />CONDUIT, COMBINER BOX <br />(PER CODE: [CEC 690.31(G)(3)] <br />LABEL LOCATION: <br />AC & DC DISCONNECT AND SUB PANEL <br />(PER CODE: CEC 690.41(B)) <br />TERMINALS ON THE LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />! <br />   <br />    <br />LABEL LOCATION: <br />RAPID SHUTDOWN <br />(PER CODE: CEC 690.56(C)(3) <br />LABEL LOCATION: <br />MAIN SERVICE PANEL & NET METER <br />(PER CODE: [CEC 705.12(B)(3)] <br />WARNING <br />THE DISCONNECTION OF THE <br />GROUNDED CONDUCTOR(S) <br />MAY RESULT IN OVERVOLTAGE <br />ON THE EQUIPMENT <br />! <br />LABEL LOCATION: <br />INVERTER <br />(PER CODE: CEC 690.31(I) <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />LABEL LOCATION: <br />DC DISCONNECT, POINT OF <br />INTERCONNECTION <br />(PER CODE: [CEC 690.13(B)]) <br />! <br />! <br />LABEL LOCATION: <br />AC DISCONNECT/BREAKER/ <br />POINT OF CONNECTION <br />(PER CODE: CEC 690.13(B) <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />AT RAPID SHUTDOWN SYSTEM <br />[CEC 690.56(C)(1)(A)] <br />LABEL LOCATION <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />RATED MAXIMUM POWER- . <br />POINT CURRENT (Imp) . <br />RATED MAXIMUM POWER- . <br />POINT VOLTAGE (Vmp) . <br />MAXIMUM SYSTEM . <br />VOLTAGE (VOC) . <br />MAXIMUM CIRCUIT . <br />CURRENT (Isc) . <br />A <br />V <br />V <br />A <br />17.89 <br />380 <br />480 <br />30 <br />LABEL LOCATION: <br />DC DISCONNECT, INVERTER# <br />(PER CODE: CEC690.53) <br />W OCCIDENTAL ST <br />(E) 200A MAIN SERVICE PANEL <br />WITH (E) 200A MAIN BREAKER <br />(E) UTILITY METER <br />(N) INVERTER <br />(N) PV MODULES <br />LABEL LOCATION: <br />AC DISCONNECT & INVERTER <br />(PER CODE: NEC690.54) <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED AC OPERATING CURRENT 21 AMPS <br />AC NOMINAL OPERATING VOLTAGE 240 VOLTS <br />(N) FUSED AC DISCONNECT <br />1 <br />7 <br />1 <br />4 <br />G <br />R <br />E <br />E <br />N <br />V <br />I <br />L <br />L <br />E <br /> <br />S <br />T <br />1714 S Greenville <br />St02/10/23