Laserfiche WebLink
I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON <br />THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND <br />ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF <br />OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE <br />WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES <br />AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO <br />FINAL BUILDING INSPECTION. <br /> SIGNATURE DATE STATE LICENSE NO. <br />PROJECT LOCATION: <br />SAS SOLAR INC <br />1801 E EDINGER AVE <br />SANTA ANA, CA 92705 <br />NO.DATE DESCRIPTION STRUC. <br />1 <br />CONTRACTOR <br />REVEL ENERGY, INC <br />2323 MAIN ST <br />IRVINE, CA 92614 <br />CSLB #1038433 / B, C46 <br />(949) 821-7171 <br />8/22/2022 INITIAL PLAN SET -- <br />ELECT. <br />A.L. <br />ARCH D (24" X 36") PRINT PAPER SIZE <br />DESCRIPTION: <br />SYSTEM INFO: <br />#1038433 / B, C46 <br />12/5/2022 <br />11/17/2022 REVISION 1 P.R. <br />--A.L.REVISION 2 <br />2/9/2023 P.R.CORRECTION 1 <br />6/21/2023 --A.L.REVISION 3 <br />6/23/2023 --A.L.REVISION 4 <br />9/12/2023 P.R.REVISION 5 <br />SIGNAGE REQUIREMENTS <br />GENERAL FIRE GUIDELINES & <br />MARKING REQTS: <br />SEC. 5. MARKINGS, LABELS, AND WARNING SIGNS. <br /> CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />CAUTION: SOLAR CIRCUIT <br />PV 6 <br />SIGNAGE <br />COMBINER BOX/ CIRCUITS/ CONDUIT/ COMBINER <br />BOX/ ENCLOSURES/ EMT ENCLOSURES1 <br />1 WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />WARNING <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO WORKING <br />INSIDE PANEL <br />1 <br />2 <br />BUILDING / STRUCTURE2 <br />CEC 705.10 - BY MAIN SERVICE PANEL: <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS <br />LOCATED AS SHOWN. <br />1801 E EDINGER AVE SANTA ANA, CA 92705 <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY <br />BE ENERGIZED IN THE OPEN POSITION <br />MAIN ELECTRIC <br />SERVICE DISCONNECT <br />INTERIOR <br />SOLAR A/C <br />DISCONNECT <br />INTERIOR <br />PV SOLAR ARRAY(S) <br />SOLAR INVERTER <br />D/C DISCONNECT <br />ROOFTOP <br />DC DISCONNECT/ BREAKER/ RECOMBINER BOX3 <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />PHOTOVOLTAIC <br />DC DISCONNECT <br />EMT/ DC CONDUIT RACEWAYS4 <br />WARNING: PHOTOVOLTAIC POWER SOURCE <br />INVERTER5 <br />AC PHOTOVOLTAIC DISCONNECT <br />OUTPUT CURRENT: <br />OPERATING VOLTAGE: 480V <br />PRODUCTION/ NET METER6 <br />WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT/ BREAKER/ POINTS OF CONNECTION7 <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />120A <br />BREAKER PANEL/ PULL BOXES8 <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />WARNING <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO WORKING <br />INSIDE PANEL <br />MAIN SERVICE DISCONNECT9 <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />WARNING <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO WORKING <br />INSIDE PANEL <br />CAUTION <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN PV <br />SYSTEM AND REDUCE SHOCK <br />HAZARD IN ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />(690.56(C)(1)(a) YELLOW WITH BLACK LETTERING) <br />RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM <br />10 <br />BY RAPID SHUTDOWN SWITCH <br />(WITHIN 3 FT)10 <br />10 <br />7 <br />4 <br />3 <br />MAX SYSTEM VOLTAGE: <br />MAX CIRCUIT CURRENT: <br />MAX RATED OUTPUT <br />CURRENT OF THE CHARGE <br />CONTROLLER OR DC-TO-DC <br />CONVERTER (IF INSTALLED): <br />POWER SOURCE OUTPUT <br />PV INVERTER <br />DC DISCONNECT <br />5 <br />8 <br />6 <br />9 <br />PV SYSTEM LABELING REQUIREMENTS <br />NOT TO SCALE <br />AC PHOTOVOLTAIC DISCONNECT <br />OUTPUT CURRENT: <br />OPERATING VOLTAGE: <br />1 <br />AC PHOTOVOLTAIC DISCONNECT <br />OUTPUT CURRENT: <br />OPERATING VOLTAGE: <br />1000V <br />55A <br />18A <br />5 <br />7 <br />4 <br />4 <br />*RAPID SHUTDOWN SWITCH <br />CAN BE EITHER THE AC <br />DISCONNECT SWITCH OR A <br />SEPARATE SWITCH. SEE PV 4 FOR <br />TYPE OF RS SWITCH <br />ARC FLASH AND <br />SHOCK HAZARD <br />APPROPRIATE PPE AND TOOLS <br />REQUIRED WHILE WORKING ON <br />THIS ENERGIZED EQUIPMENT. <br />WARNING <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION - <br />DO NOT RELOCATE THIS OVERCURRENT DEVICE <br />CEC 705.12(B)(2)(3)(b) <br />CEC 690.13(B) <br />CEC 690.13(B) <br />CEC 690.13(B) <br />CEC 690.31(G)(3) <br />CEC 690.53 <br />CEC 690.13(B) <br />CEC 690.54 <br />CEC 690.54 <br />CEC 110.16 <br />CEC 690.59, 705.12(D)(3) <br />CEC 110.27(C) <br />CEC 690.13(B) <br />CEC 690.13(B) <br />CEC 690.13(B) <br />CEC 690.27(C) <br />CEC 690.13(B) <br />CEC 690.27(C) <br />CEC 690.13(F), 705.12(B)(3-4) <br />CEC 690.59, 705.12(B)(3-4) <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION - <br />DO NOT RELOCATE THIS OVERCURRENT DEVICE <br />CEC 705.12(B)(2)(3)(b) <br />480V <br />240A <br />480V <br />240A <br />SOLAR A/C <br />DISCONNECT <br />ROOFTOP <br />1801 E Edinger Ave - <br />10111733312/7/2023