PV-4 <br />9/19/2023 <br />SHEET TITLE <br />DRAWN DATE <br />DRAWN BY PD <br />SHEET NUMBER <br />SYSTEM DETAILS <br />DC SIZE: 10.800 KW DC (STC) <br />AC SIZE: 10.000 KW AC <br />(27) APTOS SOLAR TECHNOLOGY LLC, <br />DNA-108-BF10-400W <br />(1) SOLAREDGE TECHNOLOGIES <br />SE10000H-USSN <br />(27) SOLAREDGE P401 OPTIMIZER <br />(2) SOLAREDGE TECHNOLOGIES, <br />BAT-10K1P <br />CONTRACTOR <br />PROJECT NAME & ADDRESS <br />APN #: 002-101-05 <br />AHJ: SANTA ANA CITY <br />UTILITY: SCE <br />LEE WILHITE <br />2002 N VICTORIA DR., <br />SANTA ANA, CA 92706 <br />REVISION <br />#REV. INFO DATE <br />SIGN./STAMP <br />NOTES <br />1. EXISTING PLUMBING VENTS, SKYLIGHTS,EXHAUST <br />OUTLETS, VENTILATION INTAKE AIR OPENINGS SHALL NOT <br />BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. <br />2. EQUIPMENT. INVERTERS, MOTOR GENERATORS, <br />PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC <br />PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, <br />AND CHARGE CONTROLLERS INTENDED FOR USE IN <br />PHOTOVOLTAIC POWER SYSTEMS WITH BATTERIES SHALL <br />BE IDENTIFIED AND LISTED FOR THE APPLICATION [CEC <br />690.4(B)] <br />3. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br />INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND <br />NON ROOF SWITCHES. ROOF SWITCHES TO BE NEMA 3R <br />RATED. <br />4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND <br />BONDED IN ACCORDANCE WITH CEC ARTICLE 250. <br />5. PROTECTION DEVICES FOR PV SOURCE CIRCUITS AND PV <br />OUTPUT CIRCUITS ALSO CONNECTED TO SOURCES HAVING <br />SIGNIFICANTLY HIGHER CURRENT <br />AVAILABILITY (E.G., PARALLEL STRINGS OF <br />MODULES, UTILITY POWER), SHALL BE PROTECTED AT THE <br />SOURCE FROM OVERCURRENT [CEC 690.9(A)] <br />6. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS <br />SHALL INCLUDE A RAPID SHUTDOWN FUNCTION [CEC <br />690.12] <br />7. THE UTILITY INTERACTIVE INVERTERS SHALL <br />AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE <br />CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION <br />NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND <br />SHALL REMAIN IN THAT STATE UNTIL <br />THE ELECTRICAL PRODUCTION AND DISTRIBUTION <br />NETWORK VOLTAGE HAS BEEN RESTORED. <br />[CEC 705.41] <br />8. ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE <br />LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT. [CEC <br />310.10(D)(1)] <br />9. THE MODULE CONDUCTORS MUST BE TYPE USE-2 OR <br />LISTED FOR PHOTOVOLTAIC (PV) WIRE <br />[CEC 690.31(C)] <br />10. ALL CONDUCTORS SHALL BE MARKED ON EACH END <br />FOR UNIQUE IDENTIFICATION. <br />11. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR <br />SMALLER SHALL BE IDENTIFIED AS A CONTINUOUS WHITE <br />FINISH [CEC 200.6] <br />12. THE OUTPUT OF AN INTERCONNECTED ELECTRICAL <br />POWER SOURCE SHALL BE PERMITTED TO BE CONNECTED <br />TO THE LOAD SIDE. INTERCONNECTING <br />PROVISIONS FOR OTHER POWER SOURCES SHALL COMPLY <br />WITH CEC 705.12(B)(1) THROUGH 705.12(B)(5) <br />23. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES <br />SMALLER THAN 6 AWG SHALL BE PROTECTED FROM <br />PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR <br />[CEC 690.46 & 250.120(C)] <br />24. AN EQUIPMENT GROUNDING CONDUCTOR SHALL NOT BE <br />SMALLER THAN 14 AWG [CEC 690.45] <br />25. FINE STRANDED CABLES USED FOR BATTERY TERMINALS, <br />DEVICES, AND CONNECTIONS REQUIRE LUGS AND TERMINALS IS <br />IN ACCORDANCE WITH CEC 110.14 <br />26. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED <br />IN ONE CONTINUOUS LENGTH WITHOUT A <br />SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL <br />BE MADE AS PERMITTED <br />[CEC 250.64(C)] <br />27. ALL SMOKE ALARMS, CARBON MONOXIDE ALARMS AND <br />AUDIBLE NOTIFICATION DEVICES SHALL BE LISTED AND LABELED <br />IN ACCORDANCE WITH UL 217 AND UL 2034. THEY WILL BE <br />INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 720 [IRC <br />2019 R314 & R315] <br />28. SMOKE ALARMS AND CARBON MONOXIDE ALARMS WILL BE <br />RETROFITTED INTO THE EXISTING DWELLING. THESE SMOKE <br />ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH <br />BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE <br />CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED <br />OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR <br />OF THE HOUSE.THESE ALARMS MAY BE SOLELY BATTERY <br />OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE <br />THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE <br />THE HOME, OTHERWISE, THE ALARMS MUST BE HARD WIRED <br />AND INTERCONNECTED. <br />13. EACH SOURCE INTERCONNECTION OF ONE OR MORE <br />POWER SOURCES INSTALLED IN ONE SYSTEM SHALL BE <br />MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE <br />DISCONNECTING MEANS IN ACCORDANCE WITH CEC 705.12. <br />14. THE SUM OF THE AMPERE RATING OF THE <br />OVERCURRENT PROTECTION DEVICES IN CIRCUITS <br />SUPPLYING POWER TO THE BUSBAR OR CONDUCTOR SHALL <br />NOT EXCEED 120% OF THE RATING OF BUSBAR OR <br />CONDUCTOR IN ACCORDANCE WITH CEC 705.12 <br />15. A CONNECTION AT EITHER END, BUT NOT BOTH ENDS, <br />OF A CENTER-FED PANEL BOARD IN DWELLINGS SHALL BE <br />PERMITTED WHERE THE SUM OF 125 PERCENT OF THE <br />POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE <br />RATING OF THE OVERCURRENT DEVICE PROTECTING THE <br />BUSBAR DOES NOT EXCEED 120 PERCENT OF THE CURRENT <br />RATING OF THE BUSBAR IN ACCORDANCE WITH CEC 705.12. <br />16. EQUIPMENT CONTAINING OVERCURRENT PROTECTION <br />DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR <br />CONDUCTOR SHALL BE MARKED TO INDICATE THE <br />PRESENCE OF ALL SOURCES IN ACCORDANCE WITH CEC <br />705.12. <br />17. CIRCUIT BREAKER, IF BACKFED, SHALL BE SUITABLE FOR <br />SUCH OPERATION IN ACCORDANCE WITH CEC 705.12. <br />18. TO MINIMIZE OVERHEATING OF THE BUSBAR IN <br />ELECTRICAL ENCLOSURE, THE MAIN CIRCUIT BREAKER AND <br />THE PV POWER SOURCE CIRCUIT BREAKER SHALL BE <br />PHYSICALLY LOCATED AT THE OPPOSITE END OF THE <br />BUSBAR. <br />19. ALL THE CEC REQUIRED WARNING SIGNS, MARKINGS, <br />AND LABELS SHALL BE POSTED ON EQUIPMENT AND <br />DISCONNECTS PRIOR TO ANY INSPECTIONS. <br />20. WHERE PV SYSTEM DC CIRCUIT'S RUN INSIDE A <br />BUILDING, THEY SHALL BE CONTAINED IN METAL RACEWAYS <br />TYPE MC METAL CLAD CABLE OR METAL ENCLOSURES FROM <br />POINT OF PENETRATION OF THE <br />SURFACE OF THE BUILDING TO THE FIRST READILY <br />ACCESSIBLE DISCONNECTING MEANS [CEC 690.31(G)]. <br />21. FLEXIBLE, FINE-STRANDED CABLES SHALL BE <br />TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR <br />CONNECTORS THAT ARE LISTED IN ACCORDANCE WITH CEC <br />110.14. <br />22. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. <br />CONNECTORS THAT ARE READILY <br />ACCESSIBLE AND OPERATING AT OVER 30V DC OR 15V AC <br />SHALL REQUIRE TOOL TO OPEN AND MARKED "DO NOT <br />DISCONNECT UNDER LOAD" OR "NOT <br />FOR CURRENT INTERRUPTING"[CEC 690.33(C) & (E)(2)]. <br />2002 N Victoria Dr - <br />2018116310/24/2023