My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1906 E Kemper Ave - Plan
PBA
>
Building
>
ProjectDox
>
K
>
Kemper Ave
>
1906 E Kemper Ave
>
1906 E Kemper Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:00:14 PM
Creation date
6/1/2025 11:59:58 AM
Metadata
Fields
Template:
Plan
Permit Number
20178721
101113862
Full Address
1906 E Kemper Ave
Document Relationships
101113862 - Permit
(Permit - Plan)
Path:
\Building\Permits\K\Kemper Ave\1906 E Kemper Ave
20170721 - Permit (2)
(Permit - Plan)
Path:
\Building\Permits\K\Kemper Ave\1906 E Kemper Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CODE INFORMATION <br />APPLICABLE CODES, LAWS AND REGULATIONS <br />CODE INFORMATION <br />APPLICABLE CODES, LAWS AND REGULATIONS <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />2022 CALIFORNIA RESIDENTIAL CODE (CRC) <br />2022 CALIFORNIA FIRE CODE (CFC) <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />PROJECT <br />INSTALLER <br />1 <br />4 <br /> <br />1 <br /> <br />4 <br /> <br /> <br />H <br />A <br /> <br />R <br /> <br />B <br /> <br />O <br /> <br />U <br /> <br />R <br /> <br /> W <br /> <br />A <br /> <br />Y <br /> <br /> S <br /> <br />O <br /> <br />U <br /> <br />T <br /> <br />H <br />R <br />I <br /> <br />C <br /> <br />H <br /> <br />M <br /> <br />O <br /> <br />N <br /> <br />D <br /> <br />, <br /> <br /> C <br /> <br />A <br /> <br /> <br /> <br />9 <br />4 <br /> <br />8 <br /> <br />0 <br /> <br />4 <br />( <br />5 <br /> <br />1 <br /> <br />0 <br /> <br />) <br /> <br /> 5 <br /> <br />4 <br /> <br />0 <br /> <br />- <br /> <br />0 <br /> <br />5 <br /> <br />5 <br /> <br />0 <br />C <br />O <br /> <br />R <br /> <br />P <br /> <br />O <br /> <br />R <br /> <br />A <br /> <br />T <br /> <br />I <br /> <br />O <br /> <br />N <br /> <br />, <br /> <br /> <br /> <br />S <br />Y <br /> <br />S <br /> <br />T <br /> <br />E <br /> <br />M <br /> <br />S <br />R E V I S I O N S <br />SO <br />L <br />A <br />R <br /> <br />I <br />N <br />D <br />I <br />V <br />I <br />D <br />U <br />A <br />L <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />P <br />A <br />C <br />K <br />A <br />G <br />E <br />GR <br />I <br />D <br />- <br />T <br />I <br />E <br />D <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />REV DESCRIPTION DATE DB <br />DRAWN BY: <br />DATE DRAWN <br />SCALE <br />NO <br />R <br />I <br />N <br />N <br />E <br /> <br />S <br />T <br />A <br />U <br />B <br />19 <br />0 <br />6 <br /> <br />K <br />E <br />M <br />P <br />E <br />R <br /> <br />A <br />V <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />RP-365850 <br />4. <br />0 <br />7 <br /> <br />k <br />W <br />SPRI - ANAHEIM <br />01-26-2023 <br />C. Holgado <br />CHARLENE HOLGADO <br />(N) GRID TIED PHOTOVOLTAIC SYSTEM <br />SOLAR INDIVIDUAL PERMIT PACKAGE <br />NORINNE STAUB <br />1906 KEMPER AVE <br />(714) 328-3184 <br />SANTA ANA, CALIFORNIA 92705 <br />4.07 kW <br />AHJ: SANTA ANA CITY <br />UTILITY: SOUTHERN CALIFORNIA EDISON CO <br />SATELLITE IMAGE <br />CO <br />V <br />E <br />R <br /> <br />S <br />H <br />E <br />E <br />T <br />PROJECT LOCATION <br />NTS <br />SHEET INDEX <br />SCOPE OF WORK <br />- (N) 4.070 kW PHOTOVOLTAIC SYSTEM <br />- (11) APTOS DNA-120-BF26-370W PV MODULES AND (11) ENPHASE IQ7HS-66-M-US MICROINVERTER <br />- POINT OF INTERCONNECTION AT MAIN SERVICE PANEL WITH CIRCUIT BREAKER <br />- MAIN PANEL UPGRADE TO (N) 225A/200A <br />NOTES <br />SHEET <br />PVA-0 <br />ARCHITECTURAL DRAWINGS <br />ELECTRICAL DRAWINGS <br />PVE-1 ELECTRICAL SINGLE-LINE DIAGRAM & <br />PVE-2 ELECTRICAL CALCULATION <br />PVE-3 ELECTRICAL DATA & SPECIFICATIONS <br />SPECIFICATIONS <br />PVE-4 <br />PVE-5 BRANCH DIAGRAM <br />STRUCTURAL DRAWINGS <br />PVS-1 STRUCTURAL INFORMATION & <br />PVA-0 COVER SHEET <br />PVA-1 ARRAY LAYOUT <br />EQUINOX GROUNDING DETAILS <br />PV MOUNTING DETAILS <br />Bldg# 101113862 <br />Elec# 20178721 <br />Issued 02/14/23 <br />The scope of the plans is for the <br />installation of the solar <br />photovoltaic system only and <br />the approval is subject to <br />compliance with all applicable <br />city and state codes and <br />regulations regarding <br />construction. The approval of <br />the plans does not constitute <br />any certification of the <br />accuracy, completeness, or <br />building permit status of the <br />existing buildings and <br />structures as shown. <br />1906 E Kemper Ave <br />02/15/23
The URL can be used to link to this page
Your browser does not support the video tag.