Laserfiche WebLink
SHEET: <br />DRAFTER <br />SIGNATURE <br />PROJECT ADDRESS: <br />REVISION # <br />DATE: <br />11/09/2022 <br />DRAWING <br />TYPE <br />PENGUIN HOME SOLUTIONS CHRISTIAN DANG <br />1901 LAIRD ST, <br />(000) 000-0000 <br />21860 VAN BUREN BLVD, BLDG 11, SUITE 101, <br />RIVERSIDE, CA 92518 <br />(888) 488 8001 <br />LICENSE#: C-10 1033658 <br />SANTA ANA, CA 92706 <br />PV-7 <br />PLACARDS <br /> WARNING <br /> WARNING <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE. <br />NEC SECTION LOCATION OF LABEL LABEL TEXT AND APPERANCE NEC SECTION LOCATION OF LABEL LABEL TEXT AND APPERANCE <br />690.54 ALL INTERACTIVE SYSTEM(S) POINTS OF INTERCONNECTION <br />WITH OTHER SOURCES SHALL BE MARKED AT AN ACCESSIBLE <br />LOCATION AT THE DISCONNECTING MEANS AS A POWER <br />SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE <br />NOMINAL OPERATING AC VOLTAGE. <br />690.56(B) <br />690.4(D) <br />705.10 <br />A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED <br />AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN <br />APPROVED READILY VISIBLE LOCATION. THE PLAQUE OR <br />DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER <br />SOURCE DISCONNECTING MEANS FOR THE BUILDING OR <br />STRUCTURE AND BE GROUPED WITH OTHER PLAQUES OR <br />DIRECTORIES FOR OTHER ON-SITE SOURCES. THE PLAQUE OR <br />DIRECTORY SHALL BE MARKED WITH THE WORDING <br />“C UTION: MULTIPLE SOURCES OF POWER͘” NY <br />POSTED DIAGRAMS SHALL BE CORRECTLY ORIENTED WITH <br />RESPECT TO THE DIAGRAM'S LOCATION. THE MARKING SHALL <br />COMPLY WITH 110.21(B). <br />690.13(B) <br />690.15 <br />705.20 <br />EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY <br />INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) <br />POSITION AND BE PERMANENTLY MARKED: <br />“PV SYSTEM DISCONNECT” <br />OR EQUIVALENT. <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE SHOCK <br />HAZARD IN ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />WHERE ALL TERMINALS OF THE DISCONNECTING MEANS <br />MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING <br />SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE <br />DISCONNECTING MEANS. <br />690.13(B) <br />690.15(C) <br />705.12 <br />(B)(3)(2) <br />705.12 <br />(B)(3)(3) <br />690.56 (C) <br />A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE <br />DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED <br />BREAKER FROM THE INVERTER. <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />PERMANENT WARNING LABELS SHALL BE APPLIED TO <br />DISTRIBUTION EQUIPMENT <br />(2) A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL <br />LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH <br />THAT INCLUDES THIS WORDING. THE LABEL SHALL BE <br />REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A <br />MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED <br />BACKGROUND . <br />BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT <br />LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION <br />TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN <br />APPROVED READILY VISIBLE LOCATION AND SHALL <br />INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION <br />DEVICES. THE LABEL SHALL INCLUDE A SIMPLE DIAGRAM OF <br />A BUILDING WITH A ROOF AND SHALL INCLUDE THE <br />FOLLOWING WORDS: <br />THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH <br />RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED <br />CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN <br />BLACK ON YELLOW BACKGROUND, AND THE REMAINING <br />CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM <br />HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND. <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />35 AMPS <br />240 VOLTS <br />RAPI' SHUT'OWN SWIT&H <br />)OR SOLAR P 9 S<STEM <br /> WARNING <br />THIS EQUIPMENT FED BY MULTIPLE SOURCES. <br />TOTAL RATING OF ALL OVERCURRENT DEVICES <br />EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF BUSBAR. <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND LOAD SIDES <br />MAY BE ENERGIZED IN THE OPEN POSITION <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />(1) BUILDING WITH MORE THAN ONE RAPID SHUTDOWN TYPE. FOR BUILDINGS THAT HAVE PV SYSTEMS WITH <br />BOTH RAPID SHUTDOWN TYPES OR A PV SYSTEM WITH A RAPID SHUTDOWN TYPE AND PV SYSTEM WITH NO <br />RAPID SHUTDOWN, A DETAILED PLAN VIEW DIAGRAM OF THE ROOF SHALL BE PROVIDED SHOWING EACH <br />DIFFERENT PV SYSTEM AND DOTTED LINE AROUND AREAS THAT REMAIN ENERGIZED AFTER THE RAPID <br />SHUTDOWN SWITCH IS OPERATED. <br />PHOTOVOLTAIC <br /> AC DISCONNECT <br />CAUTION: <br />MULTIPLE SOURCES OF POWER <br />WITH DISCONNECTS LOCATED AS SHOWN <br /> NE& LA%ELING RE4UIREMENTS <br />IQ8PLUS 72-2-US <br />(240V) [SI1-JUN20] <br />ENPHASE <br />INVERTERSN LA <br />I <br />R <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />MAIN SERVICE PANEL <br />"YOU ARE HERE" <br />(E) SUBPANEL <br />MSPSUB <br /> JB <br /> AC CB <br /> PV AC DISCONNECT SWITCH <br />PV IQ COMBINER BOX <br />1901 N Laird St <br />12/06/22