Laserfiche WebLink
MSPSUB <br /> JB <br /> AC CB <br />SHEET: <br />DRAFTER <br />SIGNATURE <br />PROJECT ADDRESS: <br />REVISION # <br />DATE: <br />11/09/2022 <br />DRAWING <br />TYPE <br />PENGUIN HOME SOLUTIONS CHRISTIAN DANG <br />1901 LAIRD ST, <br />(000) 000-0000 <br />21860 VAN BUREN BLVD, BLDG 11, SUITE 101, <br />RIVERSIDE, CA 92518 <br />(888) 488 8001 <br />LICENSE#: C-10 1033658 <br />SANTA ANA, CA 92706 <br />SITE PLAN <br />SCALE: 1/16" = 1'-0"1 <br />PV-2 <br />SITE PLAN <br />NOTES: <br />· SMOKE / CARBON MONOXIDE ALARMS ARE REQUIRED TO BE <br />INSTALLED AND IN WORKING CONDITION. <br />· NOTIFY UTILITY COMPANY BEFORE ACTIVATION OF PV SYSTEM. <br />· DO NOT INSTALL INVERTER WHERE IT COULD BE EXPOSED TO <br />DIRECT SUNLIGHT TO AVOID UNWANTED POWER REDUCTION DUE TO <br />AN INCREASE IN THE INTERNAL TEMPERATURE OF THE INVERTER. <br />NORTH <br />APN #: 6212013049 <br />SPRINKLER SYSTEM: NO <br />TOTAL ROOF AREA: 2038.12 <br />SOLAR ARRAY AREA: 513.07 <br />% AREA COVERAGE: 25.17% <br />(N) IQ8PLUS 72-2-US (240V) [SI1-JUN20] <br />ENPHASE INVERTERS <br />(N) IQ COMBINER BOX <br />(N) AC DISCONNECT SWITCH <br />(E) RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />(E) MAIN SERVICE PANEL <br />(SOLAR POINT OF CONNECTION) <br />(N) PV ARRAY AR-01 <br />(E) PROPERTY LINE <br />(E) SUB HOUSE <br />LAI <br />R <br />D <br /> <br />STR <br />E <br />E <br />T <br />(E) DRIVEWAY <br />1204.2.1.1 PATHWAYS TO RIDGE NOT FEWER THAN TWO 36-INCH-WIDE <br />(914 MM) PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST <br />ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT <br />FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR <br />DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A <br />PHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36-INCH-WIDE (914 MM) <br />PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED <br />ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN <br />ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT <br />ROOF PLANES <br />FIRE CODE <br />1204.2.1.2 SETBACKS AT RIDGE FOR PHOTOVOLTAIC ARRAYS <br />OCCUPYING 33 PERCENT OR LESS OF THE PLAN VIEW TOTAL <br />ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 <br />MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL <br />RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN <br />33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A <br />SETBACK OF NOT LESS THAN 36 INCHES (457 MM) WIDE IS <br />REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. <br />(N) PV ARRAY AR-02 <br />ROOF ACCESS POINT <br />44'-9" <br />98'-4" <br />12 <br />3 <br />' <br />- <br />9 <br />" <br />97 <br />' <br />- <br />3 <br />" <br />(E) SUB PANEL <br />ROOF ACCESS POINT <br />Exp. 3-31-19 <br />No. C58724 <br />NITRAMW.DYO <br />REGISTEREDPROFESSIONALENGINEER <br />C <br />V <br />L <br />FOETATS <br />ALIFORNIAICIL <br />-213 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2022-4673 Structural Only <br />November 10, 2022 <br />1901 N Laird St <br />12/06/22