Laserfiche WebLink
MSPSUB <br /> JB <br /> AC CB <br />SHEET: <br />DRAFTER <br />SIGNATURE <br />PROJECT ADDRESS: <br />REVISION # <br />DATE: <br />11/09/2022 <br />DRAWING <br />TYPE <br />PENGUIN HOME SOLUTIONS CHRISTIAN DANG <br />1901 LAIRD ST, <br />(000) 000-0000 <br />21860 VAN BUREN BLVD, BLDG 11, SUITE 101, <br />RIVERSIDE, CA 92518 <br />(888) 488 8001 <br />LICENSE#: C-10 1033658 <br />SANTA ANA, CA 92706 <br />PV-3 <br />ARRAY LAYOUT <br />MODULE DETAILS <br />SCALE: 1/2" = 1'-0" 2 <br />ROOF PLAN WITH MODULES LAYOUT <br />SCALE: 3/32" = 1'-0" 1 <br />ADDITIONAL NOTES: <br />· FINAL LOCATION OF ALL CONDUIT AND JUNCTION BOXES TO BE DETERMINED AT TIME OF INSTALLATION. <br />· CONDUIT TO BE PAINTED TO MATCH EXTERIOR OF RESIDENCE WHERE APPLICABLE AND IS TO BE SUPPORTED <br />EVERY 10' MAX. <br />· 30" WIDE X 36" DEEP WORKING SPACE CLEARANCES REQUIRED ABOUT ALL ELECTRICAL EQUIPMENT. <br />· STAGGER PENETRATIONS TO EVENLY DISTRIBUTE LOAD ACROSS ALL TRUSSES UNDER ARRAY. <br />· ALL DIMENSIONS ARE APPROXIMATIONS. <br />· DO NOT INSTALL INVERTER WHERE IT COULD BE EXPOSED TO DIRECT SUNLIGHT TO AVOID UNWANTED POWER <br />REDUCTION DUE TO AN INCREASE IN THE INTERNAL TEMPERATURE OF THE INVERTER. <br />CONSTRUCTION NOTES <br />· ROOF PITCH: 31° <br />· ROOF CLADDING: COMPOSITION SHINGLE <br />· ROOF STRUCTURE: 2" X 6" RAFTERS @ 24" O.C O/C <br />· MOUNTS ARE ON GRID SPACING, OCCURRING AT RAFTERS. <br />· VERIFY RAFTER LOCATIONS IN FIELD. <br />· REFER TO MODULE AND RACKING MFR'S INSTALL MANUALS. <br />· MAX SPAN BETWEEN MOUNTS: 72" O.C. <br />· PLUMBING AND MECHANICAL VENTS SHALL NOT BE COVERED <br />BY SOLAR MODULES. <br />· ALL FASTENERS STAINLESS STEEL U.O.N. <br />(N) IQ8PLUS 72-2-US (240V) [SI1-JUN20] <br />ENPHASE INVERTERS <br />(N) IQ COMBINER BOX <br />STRING 2 <br />STRING 1 <br />ROOF AREA STATEMENT <br />ROOF MODULES <br />QTY PITCH TRUE <br />ORIENTATION <br />1 17 31°125° <br />2 6 31°305°NORTH <br />SPECS: <br />L : 76.4" <br />W : 41.3" <br />D : 1.38" <br />49.6 LBS <br />CANADIAN <br />SOLAR (CSI) <br />CS3N-395MS <br />(395W) <br />76.4" <br />41.3" <br />1.38" <br />17 MODULES 125° AZIMUTH <br />MODULE ROOF AREA: 680.62 <br />SOLAR ARRAY AREA: 378.95 <br />% AREA COVERAGE: 55.68% <br />6 MODULES 305° AZIMUTH <br />MODULE ROOF AREA: 1136.03 <br />SOLAR ARRAY AREA: 134.12 <br />% AREA COVERAGE: 11.81 % <br />2" X 6" RAFTERS @ 24" O.C <br />(N) UNIRAC SOLARMOUNT <br />STANDARD RAIL <br />(N) CONDUIT RUN: 3/4" EMT <br />(N) ROOF MOUNTS <br />EVERY 72" O.C MAX <br />(N) JUNCTION BOX <br />(UNDER ARRAY) <br />(N) PV ARRAY AR-01 <br />(378.95 SQ.FT.) <br />(E) MAIN SERVICE PANEL <br />(SOLAR POINT OF CONNECTION) <br />(E) SUB PANEL <br />(N) PV ARRAY AR-02 <br />(134.12 SQ.FT.) <br />PV-4 <br />1 <br />31° <br />31° <br />(N) AC DISCONNECT SWITCH <br />6'-11" <br />18'-7" <br />3'3' <br />3' <br />7'-5" <br />3'-6" <br />8'-10" <br />2'-9" <br />Exp. 3-31-19 <br />No. C58724 <br />NITRAMW.DYO <br />REGISTEREDPROFESSIONALENGINEER <br />C <br />V <br />L <br />FOETATS <br />ALIFORNIAICIL <br />-213 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2022-4673 Structural Only <br />November 10, 2022 <br />NOTE: <br />Engineer of Record assumes that all structural <br />components of the existing building were permitted <br />and met the requirements of the Building Code at the <br />time of construction. Solar Contractor shall field verify <br />that the roof framing is in its existing permitted <br />condition and capable of supporting required live <br />loads. Framing specified on solar plans shall be <br />assumed to be minimum size and spacing, actual <br />framing may be different. <br />1901 N Laird St <br />12/06/22