My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1901 N Laird St - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Laird St
>
1901 N Laird St
>
1901 N Laird St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:00:16 PM
Creation date
6/1/2025 11:59:59 AM
Metadata
Fields
Template:
Plan
Permit Number
20178076
101112934
Full Address
1901 N Laird St
Document Relationships
101112934 - Permit
(Permit - Plan)
Path:
\Building\Permits\L\Laird St\1901 N Laird St
20178076 - Permit
(Permit - Plan)
Path:
\Building\Permits\L\Laird St\1901 N Laird St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET: <br />DRAFTER <br />SIGNATURE <br />PROJECT ADDRESS: <br />REVISION # <br />DATE: <br />11/09/2022 <br />DRAWING <br />TYPE <br />PENGUIN HOME SOLUTIONS CHRISTIAN DANG <br />1901 LAIRD ST, <br />(000) 000-0000 <br />21860 VAN BUREN BLVD, BLDG 11, SUITE 101, <br />RIVERSIDE, CA 92518 <br />(888) 488 8001 <br />LICENSE#: C-10 1033658 <br />SANTA ANA, CA 92706 <br />PV-5 <br />SINGLE LINE DIAGRAM <br />9.085 kW (DC) SOLAR ARRAY: <br />(23) CANADIAN SOLAR (CSI) CS3N-395MS (395W) WITH <br />(23) ENPHASE IQ8+ INVERTERS :IQ8PLUS 72-2-US (240V) [SI1-JUN20] <br />(1) STRING OF (13) MODULES & (1) STRING OF (10) MODULES <br />NOTES: <br />· CONDUTORS ON ROOF MUST BE SUNLIGHT RESISTANT, 90°C RATED AND SUITABLE FOR WET LOCATIONS. <br />· SEE RACKING SPEC SHEETS FOR RACKING EQUIPMENT GROUNDING METHOD. <br />· ALL GROUNDING CONDUCTORS MUST BE PROTECTED FROM DAMAGE IF NOT INSTALLED IN CONDUIT. <br />· ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR <br /> SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF. <br />· ALL DEVICES USED FOR BONDING FRAMES OF MODULES OR OTHER EQUIPMENT TO THE GROUNDING SYSTEM <br /> MUST BE LISTED AND IDENTIFIED FOR THE PURPOSE. <br />· ALL CONDUCTORS SHALL BE COPPER. <br />· ALL ROOFTOP RACEWAYS SHALL BE INSTALLED A>=7/8" ABOVE ROOF. <br />· INTEGRATED GROUNDING IN ACCORDANCE WITH THE RACKING MANUFACTURER INSTALLATION INSTRUCTIONS <br />CAN ONLY BE USED FOR BONDING THE MODULES TO THE RACKING WHERE THE SPECIFIC MODULE CATALOG <br />NUMBER HAS BEEN TESTED TO UL2703 STANDARDS BY AN ACCREDITED NRTL. WHERE THE MODULE CATALOG <br />NUMBER IS NOT PART OF THE RACKING SYSTEM APPROVED MODULE LIST, BOND ALL MODULES AND ALL RAILS <br />USING A UL2703 LISTED LAY-IN LUG SUCH AS ILSCO GBL-4DBT. <br />(2) 5/8" X 8' GND RODS SPACED <br />6' (MIN.) APART IF NO UFER <br />HOME LOADS <br />#4 AWG CU GEC <br />120/240 VAC SERVICE <br />EXISTING 125A DUAL MAIN <br />SERVICE PANEL W/ 100A <br />MAIN BREAKER. <br />MAIN SERVICE PANEL IS NOT CENTER FED. <br />100AMP 2-POLE <br />MAIN BREAKER <br />(2) 5/8" X 8' GND RODS SPACED <br />6' (MIN.) APART IF NO UFER <br />UTILITY <br />METER <br />N <br />G <br />UTILITY <br />METER <br />IQ COMBINER <br />15 AMPS <br />ENPHASE MONITORING <br />JUNCTION <br />BOX <br />AC POWER LINE <br />PLC OVER AC LINE <br />CONDUCTORS EXPOSED TO FREE AIR <br />(4) #12 AWG ENPHASE-TRUNK WIRE <br />(1) #6 AWG BARE COPPER GROUND <br />WIRE IN CONDUIT CAN BE #8 AWG THWN-2 <br />3/4" EMT OR EQUIVALENT <br />(4) #10 AWG THWN-2 CONDUCTORS <br />(1) #8 AWG THWN-2 GROUND <br />AC DISCONNECT <br />IQ8+ MICROINVERTER <br />WIFI/ETHERNET <br />& CELLULAR <br />3/4" EMT OR EQUIVALENT <br />(2) #8 AWG THWN-2 CONDUCTORS <br />(1) #8 AWG THWN-2 NEUTRAL <br />(1) #8 AWG THWN-2 GROUND <br />NEW SQUARE D <br />DU222RB <br />60AMP, 240V, 2P <br />NON-FUSED, <br />NEMA 3R ENCLOSURE <br />(OR EQUIV.) <br />AR-01 & AR-02 <br />(23) CANADIAN SOLAR (CSI) <br />CS3N-395MS (395W) IN (1) STRING OF <br />(13) MODULES & (1) STRING OF (10) <br />MODULES <br />(23) <br />20 AMPS <br />20 AMPS <br />(E) 125A <br />SUB PANEL <br />40A <br />POINT OF <br />CONNECTION <br />1901 N Laird St <br />12/06/22
The URL can be used to link to this page
Your browser does not support the video tag.