Laserfiche WebLink
ENGINEERED POWER SOLUTIONS <br />72 SOUTH MAIN STREET, SUITE A <br />TEMPLETON, CA 93465 <br />Solar Warehouse Rail Analysis – Generic Packet <br />9) Any design parameter or scenario that is outside those listed in this packet <br />requires a site-specific analysis. This packet is only to be used by a design <br />professional with sufficient knowledge of the governing building code definitions and <br />design parameters listed in this packet so that an accurate determination of the final <br />project specific requirements can be made. <br />10) Roof interior (zone 1), edge (zone 2), and corner zones (zone 3) are considered for <br />this analysis. Determination of the zone size and locations are provided in Section <br />2.4 of this packet. <br />11) See section 2.4 of this packet for further information on Roof Zones. Roof shall be <br />single Gable/Hip type roof only. Stepped, Monoslope, Sawtooth, Domed, and <br />Multispan Gable Roofs are not included and require a site-specific analysis. <br />12) Ground Elevation Factor is conservatively assumed to be 1.00 for all conditions <br />per note 1 of Table 26.9-1 in ASCE 7-16. <br />Page 10 <br />2004 W Picasso - <br />2018062008/29/23