Laserfiche WebLink
N <br />AR <br />- <br />0 <br />1 <br />AR-02 <br />JB <br />JB <br />DEAN TRAN RESIDENCE <br />2004 PICASSO, SANTA ANA, CA 92704 <br />PHONE: 714-606-3502 <br />EMAIL: jamesdeanofmath@gmail.com <br />APN: 412-551-14 <br />SHEET SIZE SHEET NAME <br />5628 BALDWIN AVE. <br />TEMPLE CITY, CA 91780 <br />PHONE NO.:626-353-4787 <br />LICENSE TYPE: B, C-46 ; LICENSE #: 1007552 <br />info@brightspotsolar.com <br />REVISIONS <br />REVDATE DESCRIPTION <br />SHEET NUMBER <br />PV 1.1 <br />ANSI B <br />11" X 17" <br />R04/13/2023 DRAFT REVIEW <br />SYSTEM SIZE: 2.160 kW DC <br />1.740 kW AC <br />MODULE TYPE & AMOUNT: (6) LONGI SOLAR LR4-60-HPB-360M <br />MODULE DIMENSIONS: (L/W/H) 69.9"/41.41"/1.38" <br />INVERTER: (6) ENPHASE ENERGY IQ8PLUS-72-2-US [240V][SI1-SB] <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br />SYSTEM LEGENDS: <br />EXISITNG EXTERIOR MAIN SERVICE PANEL <br />AND POINT OF INTERCONNECTION <br />(6) LONGI SOLAR LR4-60-HPB-360M WITH ENPHASE <br />ENERGY IQ8PLUS-72-2-US [240V][SI1-SB] <br />MICROINVERTERS MOUNTED UNDER EACH MODULE. <br />NEW ROOFTOP JUNCTION BOXJB <br />FIRE SETBACKS (18" MIN. / 36" MAX) <br />ROOFTOP CONDUIT RUN <br />ROOF OBSTRUCTIONS <br />SYSTEM SIZE: 2.160 kW DC <br />1.740 kW AC <br />MODULE TYPE & AMOUNT: (6) LONGI SOLAR LR4-60-HPB-360M <br />MODULE DIMENSIONS: (L/W/H) 69.9"/41.41"/1.38" <br />INVERTER: (6) ENPHASE ENERGY IQ8PLUS-72-2-US [240V][SI1-SB] <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br /> ROOF ACCESS POINT <br />ROOF ACCESS POINT PER CRC <br />324.6 SHALL NOT BE LOCATED IN <br />AREAS THAT REQUIRE THE <br />PLACEMENT OF GROUND LADDERS <br />OVER OPENINGS SUCH AS <br />WINDOWS OR DOORS, AND <br />LOCATED AT STRONG POINTS OF <br />BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS <br />POINT DOES NOT CONFLICT WITH <br />OVERHEAD OBSTRUCTIONS SUCH <br />AS TREE LIMBS, WIRES OR SIGNS. <br />CIRCUIT(S) <br />CIRCUIT #2 - ---- MODULES <br />CIRCUIT #1 - 6 MODULES <br />SITE PLAN <br />MP <br />SCALE: 1/8" = 1'-0" <br />1 SITE PLAN <br />PV 1.1 <br />CB NEW IQ COMBINER BOX X2-IQ-AM1-240-4 <br />[CRD-PCS NEM] W/ IQ ENVOY MONITORING, <br />1-PHASE,240V <br />SE EXISTING UTILITY METER AND <br />SERVICE ENTRANCE SECTION <br />ARRAY DETAILS: <br />MODULE - 4 <br />SLOPE - 18° <br />AZIMUTH - 270° <br />MATERIAL - CONCRETE W-TILE <br />TRUSS SIZE & SPACING - 2"X4" @ 24" O.C. <br />AR-01 <br />MODULE - 2 <br />SLOPE - 18° <br />AZIMUTH - 180° <br />MATERIAL - CONCRETE W-TILE <br />TRUSS SIZE & SPACING - 2"X4" @ 24" O.C. <br />AR-02 <br />MP <br /> <br />SE <br />CB <br />EXISTING PHOTOVOLTAIC ARRAY <br />(9) SUNPOWER SPR-X21-350-BLK-E-AC <br />08-15-23 <br />2004 W Picasso - <br />2018062008/29/23