My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006 N Deodar St - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Deodar St
>
2006 N Deodar St
>
2006 N Deodar St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:00:12 PM
Creation date
6/1/2025 12:00:02 PM
Metadata
Fields
Template:
Plan
Permit Number
20181911
Full Address
2006 N Deodar St
Permit Number (Not in SAPIN)
01118000
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> <br />LETTER REPORT <br />GAF ENERGY LLC <br />Intertek Report: 105171274LAX-001a <br /> <br /> <br />Version: 21-June-2019 Page 3 of 5 GFT-OP-10a <br />SECTION 2 <br />EVALUATION TO UL 3741 <br /> <br />Please see below table for the approved list of PVHCS (sub-assembly not included) <br /> <br />Timberline Solar, in combination with the Delta Electronics components and components <br />that are listed under the user manual revision of Rev 2.1 has been evaluated as a system to <br />the requirements in ANSI/CAN UL 3741 Photovoltaic Hazard Control. When installed in <br />accordance with manufacturer’s installation instructions and this report, this system meets <br />the requirements of Article 690.12 of the National Electrical Code for 2014, 2017 and 2020. <br /> <br />The terms to describe this function vary slightly in each code cycle: <br />2014A: “Rapid Shutdown” (RSD) <br />2017B: “PV Rapid Shutdown Array” (PVRSA) <br />2020C “PV Hazard Control System” (PVHCS) <br /> <br />PV Hazard Control System (PVHCS) Components (sub-assemblies not included) <br />Component & <br />Function Manufacturer Model No. Certification/Standards <br />Years of <br />Compliance to <br />690.12 <br />Rapid Shutdown <br />System (Mid <br />Circuit <br />Interrupters <br />(MCI)) <br />Delta <br />Electronics <br />GPI00010117, <br />GPI00010119 <br />UL 1741 PVRSE 2014, 2017, <br />2020 <br />Rapid Shutdown <br />System (Smart <br />RSS) <br />Delta <br />Electronics GPI00010105 D UL 1741 PVRSE 2014, 2017, <br />2020 <br /> <br /> <br />Inverters Delta <br />Electronics <br />M8-TL-US, M6-TL- <br />US, M5-TL-US, M4- <br />TL-US, M10-TL-US <br />UL 1741 2014, 2017, <br />2020 <br /> <br /> <br />PV Shingle <br />Module (Solar <br />Shingle) <br />GAF Energy <br />294000328 D UL 61730 & UL 7103 2014, 2017, <br />2020 <br /> <br />TLS-1 D UL 61730 & UL 7103 <br />Wire Cover GAF Energy 294000204 D <br />Tested in end-product <br />within UL 3741 & UL <br />7103 <br />2014, 2017, <br />2020 <br /> <br /> <br />Top Flashing <br />Assembly GAF Energy 294000300 D <br />Tested in end-product <br />within UL 3741 & UL <br />7103 <br />2014, 2017, <br />2020 <br /> <br /> <br />Transition Box GAF Energy 294000257 D <br />Tested in end-product <br />within UL 3741 & UL <br />7103 <br />2014, 2017, <br />2020 <br /> <br /> <br />Pass Through <br />Device GAF Energy 294000200 D <br />Tested in end-product <br />within UL 3741 & UL <br />7103 <br />2014, 2017, <br />2020 <br /> <br /> <br />Jumper Module GAF Energy 294000215 D UL 7103 and evaluated 2014, 2017, <br />2006 N Deodar St - 101118000 & <br />20181911 <br />6/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.