Laserfiche WebLink
Wire Schedule BIPV Shingle (PV Module) <br />REF QTY Wire Size / Type QTY Wire Size / Type Conduit Notes QTY Make/Model Max output Power <br />1 (2)AWG PV WIRE, USE-2 COPPER N/A (OR CODE APPROVED EQUIVALENT)GAF Energy Timberline Solar ES (46W)46W <br />2 (2)AWG THWN-2 (POS, NEG)(1)AWG THWN-2 (GND)EMT (OR CODE APPROVED EQUIVALENT)Rapid Shutdown Device <br />3A (3)AWG THWN-2 (L1,L2,N)(1)AWG THWN-2 (GND)EMT (OR CODE APPROVED EQUIVALENT)QTY Make/Model Max Output <br />3B Delta GPI00010105 20A <br />3C Inverter(s) <br />4 REF Make/Model AC Voltage Ground Rated Power Max Output Current <br />5 INV1 Delta M4-TL-US 240V No <br />6 INV2 <br />7 INV3 <br />8 <br />Energy Shingle Part Number:TLS-1 <br />ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV A <br />KW (DC)KW (AC)Delta M4-TL-US <br />GAF Energy Timberline Solar ES (46W)ELECTRICAL DIAGRAM <br />BY:ZDucatt <br />4000W 16.0A <br />4 (1) <br />92705 B #1062345 C-10 San Rafael CA <br />(56) <br />Santa Ana CA <br />3/4in <br />3/4in#10 <br />#10#10 <br />#10 <br />PV4 <br />#12 <br />9/27/2023 <br />(56) <br />94903 <br />Ronald Shepherd NONE <br />(1) <br />2.576 <br />2006 Deodar Street 973-628-3411 125 Mitchell Blvd, Suite D <br />GROUNDING & GENERAL NOTES (CONT'D) <br />5.TRANSITION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - <br />TRANSITION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE <br />TRANSITIONS. <br />6.AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC <br />DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. <br />7.CONDUIT CARRYING THE DC WIRES ARE BONDED AT THE INVERTER. <br />8. INVERTERS ARE UL 1741 COMPLIANT. <br />INTERCONNECTION NOTES <br />1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95] <br />2. SUPPLY SIDE INTERCONNECTION ACCORDING TO[NEC 2014, 2017 -705.12(A), NEC <br />2020, 2023 -705.11] WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH <br />[NEC 240.21(B)] <br />DISCONNECT NOTES <br />1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS <br />OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS <br />MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) <br />2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE <br />LOCKABLE, AND BE A VISIBLE-BREAK SWITCH <br />GROUNDING & GENERAL NOTES <br />TIMBERLINE SOLAR USES BIPV SHINGLES (PV MODULES) THAT ATTACH DIRECTLY TO THE ROOF DECKING LIKE <br />ORDINARY ASPHALT SHINGLES.THE BIPV SHINGLES HAVE NO METAL FRAME AND ARE NOT RACK <br />MOUNTED.THE SYSTEM HAS NO EXPOSED, CONDUCTIVE METAL AND REQUIRES NO EQUIPMENT GROUND <br />CONDUCTOR (EGC) FOR THE BIPV SHINGLES, WIRE COVERS OR TRANSITION BOX.THE EGC PATH BEGINS AT <br />THE CONNECTION OF THE CONDUIT (EMT OR FMC, TYPICALLY) AT THE TRANSITION BOX OR PASS THROUGH <br />DEVICE AND TERMINATES AT THE MAIN SERVICE PANEL. <br />TIMBERLINE SOLAR AS A SYSTEM HAS BEEN LISTED TO MEET THE RAPID SHUTDOWN REQUIREMENTS OF <br />ARTICLE 690.12 IN THE 2020, 2017 AND 2014 NEC (ANSI/NFPA 70).ANY LOSS OF CONNECTION TO THE <br />UTILITY GRID WILL TRIGGER RAPID SHUTDOWN OF THE DELTA MCI AND/OR DELTA RSS PV RAPID <br />SHUTDOWN EQUIPMENT (PVRSE) LISTED TO ANSI UL 1741 AND AS A PV HAZARD CONTROL SYSTEM (PVHCS) <br />LISTED TO ANSI/CAN/UL 3741. <br />1.A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [NEC 690.47(C)(3)] <br />2.PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. <br />3.DC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE <br />4.ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER <br />CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. <br />MAIN SERVICE <br />PANEL <br />(E)200 A BUSBAR <br />(E)200 A MAIN BREAKER <br />200 A/2P(E)20 A/2P(N) <br />string(s)of2 28 INV1 <br />3A <br />2006 N Deodar St - 101118000 & <br />20181911 <br />6/11/2024