Laserfiche WebLink
X 1 <br />1 1 <br />1 <br />1 <br />X <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />X <br />1 <br />1 1 1 1 1 1 1 1 <br />2 1 1 <br />X 1 <br />1 1 1 <br />1 1 1 1 1 1 <br />X 1 2 <br />1 X 1 <br />1 1 11 X <br />1 1 <br />1 <br />1 1 1 1 <br />1 1 1 1 1 1 X 1 <br />1 1 1 1 1 1 1 X <br />1 X 1 <br />X 1 <br />1 1 1 <br />1 1 1 1 1 1 <br />1 1 1 1 X 1 <br />X 1 2 <br />1 1 1 <br />1 1 11 1 <br />1 1 <br />X <br />1 <br />1 <br />1 1 1 1 <br />1 1 1 1 1 1 1 <br />X 1 1 X 1 1 X <br />MODULE: <br />YOTTA <br />YSM-B450-1 <br />450 WATTS <br />40.87'' <br />82.44'' <br />SHEET KEYNOTES <br />1. ROOF MATERIAL: TPO <br />2. ROOF STRUCTURE: TRUSS 2'-0" O.C. <br />3. ATTACHMENT TYPE: UNIRAC BALLASTED MOUNT RM10 EVO <br />4. MODULE MANUFACTURER: YOTTA <br />5. MODULE MODEL: YSM-B450-1 <br />6. MODULE LENGTH: 82.44'' <br />7. MODULE WIDTH: 40.87'' <br />8. MODULE WEIGHT: 61.73 LBS. <br />9. SEE SHEET PV-3 FOR DIMENSION(S) <br />10. MIN. FIRE OFFSET: 4' FROME EDGE ONLY <br />11. TOTAL AREA: 2801 SQ. FT. <br />12. TOTAL WEIGHT: 9318 LBS. <br />13. AVERAGE PSF: 3.33 PSF <br />14. MAX. VERTICAL STANDOFF: IN ACCORDANCE WITH <br />MODULE MANUFACTURER'S INSTRUCTIONS. <br />15. STANDOFF STAGGERING: NO <br />16. RAIL MANUFACTURER (OR EQUIV.): UNIRAC <br />17. RAIL MODEL (OR EQUIVALENT): RM10 EVO <br />18. MAX. RAFTER SPAN: N/A <br />19. ARRAY MAX HEIGHT: 16 IN. <br />20. RACKING WEIGHT: 309 LBS <br />21. MODULE WEIGHT: 5371 LBS <br />22. BALLAST WEIGHT: 3584 LBS <br />23. MAX BAY LOAD (DEAD): 128 LBS <br />24. 310771 RM10 ATTACHMENT KIT <br />25. 3/8-16 STRUT NUT x2 <br />26. ATTACHMENT TYPE: U-ANCHOR U-2400 <br />27. #15 X 4" ANCHOR SCREW: 8 PER ATTACHMENT <br />28. SEISMIC ATTACHMENTS COUNT: 17 <br />29. ATTACHMENT KIT WEIGHT: 55.25 LBS <br />PV-3 <br />ARRAY PLAN <br />ENGINEER OF RECORD <br />DATE: 8.21.2023 <br />DESIGN BY: V.D. <br />CHECKED BY: D.A. <br />AZ-3320 <br />2007 S MAIN ST, <br /> SANTA ANA, CA 92707 <br />PAPER SIZE: 36" x 24" (ARCH D) <br />A B C D E F G H I J K L M N O <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />A B C D E F G H I J K L M N O <br />CONTRACTOR <br />E2SOL <br />PHONE: <br />LIC. NO.: <br />UNAUTHORIZED USE OF THIS <br />DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN <br />VIOLATION OF U.S. COPYRIGHT LAWS <br />AND WILL BE SUBJECT TO CIVIL <br />DAMAGES AND PROSECUTIONS. <br />P <br />P <br />NO. DESCRIPTION DATE <br />PROJECT <br />REVISION / RELEASE <br />SHEET NUMBER: <br />SHEET TITLE: <br />401-489-2273 <br />APN: 403-164-31 <br />REPC-134 <br />NEW PV SYSTEM: 39.150 kWp <br />1 REVISION 1 01.10.2024 <br />N <br />EW <br />S <br />0 1/8" = 1'-0" <br />ARRAY PLAN01 4' 8' <br />BALLAST MOUNTED <br />SOLAR MODULES <br />BAY WITH MICROINVERTER <br />(INVERTER WEIGHT: 12 LBS.) <br />1. FIELD VERIFY ALL MEASUREMENTS <br />2. SEE SHEET G-1 FOR LEGEND OF SYMBOLS <br />3. RELOCATE DRAIN PVC PIPES IF NEEDED. <br />GAS LINES TO REMAIN <br />GENERAL NOTES <br />48'-3" <br />89'-5" <br />60'-7" <br />75'-0" <br />BAY WITH BALLASTS <br />4 <br />3 <br />19 <br />5 6 7 8 <br />D1 RACKING DETAIL (TRANSVERSE) <br />NOT TO SCALE <br />D3 DETAIL (TRANSVERSE) <br />NOT TO SCALED2RACKING DETAIL (TOP) <br />NOT TO SCALE <br />7 <br />6 <br />9 <br />D4 DETAIL (TRANSVERSE) <br />NOT TO SCALE <br />D5 DETAIL (TRANSVERSE) <br />NOT TO SCALE <br />24 <br />25 <br />24 <br />MODULE CLIP W/BOLT <br />MODULE CLIP PIN BOLT <br />ATTACHMENT KIT <br />BAY ASSEMBLY <br />ROOF PAD <br />U-ANCHOR <br />D6 DETAIL (BAY WITH ATTACHEMENT) <br />NOT TO SCALE <br />26 <br />24 <br />24 <br />27 <br />28 29 <br />BAY WITH ATTACHMENTX <br />1 <br />1 Signed 1/10/2024 <br />2007 S Main St - 101117244 & <br />20181345 <br />3/20/2024