Laserfiche WebLink
30A/3P <br />CB1 <br />(87) YOTTA <br />YSM-B450-1 <br />450 WATT <br />(22) YOTTA <br />DPI-208 <br />240V <br />MICROINVERTER <br />20 MODULES <br />IN BRANCH <br />A <br />3 <br />(N) AC DISCONNECT <br />240 VAC, 200A, 3/P <br />NEMA 3R, 42 KAIC <br />G <br />5EQUIPMENT ABOVE <br />LINE IS (N) NEW <br />EQUIPMENT BELOW <br />LINE IS (E) EXISTING <br />UNLESS OTHERWISE NOTED. <br />G <br />L1 <br />L2 <br />L3 <br />N <br />(N) AC LOAD CENTER <br />200A, 120/240V, 3Ø <br />NEMA 3R, 42 KAIC <br />1 <br />BARE #6 CU <br />1 <br />BARE #6 CU <br />1 <br />BARE #6 CU <br />1 <br />BARE #6 CU <br />1 <br />BARE #6 CU <br />20 MODULES <br />IN BRANCH <br />В <br />20 MODULES <br />IN BRANCH <br />С <br />20 MODULES <br />IN BRANCH <br />D <br />7 MODULES <br />IN BRANCH <br />E <br />30A/3P <br />CB2 <br />30A/3P <br />CB3 <br />30A/3P <br />CB4 <br />30A/3P <br />CB5 <br />ROUTER <br />GATEWAY <br />20A/2P <br />СВ6 <br />4 <br />NOTE: <br />RAPID SHUTDOWN INITIATION DEVICE (RSID) CONFORMING WITH <br />690.12. THE RAPID SHUTDOWN CAN ALSO BE INITIATED BY ONE <br />OF THE FOLLOWING METHODS: <br />· AC BREAKER IS TURNED OFF. <br />· AC TO THE INVERTER IS DISCONNECTED BY ANOTHER <br />METHOD (INTENTIONALLY OR AS RESULT OF A FAULT) <br />· INVERTER ON/OFF SWITCH IS TURNED OFF. <br />· ALL THE ABOVE SHUTS DOWN MICROINVERTERS OR <br />TRANSMITTER WHENEVER SUNSPEC SIGNAL IS INTERRUPTED. <br />VV(N) PV METER <br />NEMA 3R, SCCR = 42 KA <br />(N) JUNCTION BOX <br />NEMA 3R <br />2 <br />TO (E) GROUNDING <br />ELECTRODE <br />(Е) MAIN SERVICE SWITCHBOARD <br />120/240 V 3Ø, 4W <br />MAIN BUSS: 600A <br />(E) <br />UTILITY <br />METER TO UTILITY <br />GRID <br />120/240V, 3Ø <br />MAIN <br />(E) 600A <br />G <br />N <br />L2 <br />L1 <br />L3 <br />PV SYSTEM EQUIPPED WITH RAPID <br />SHUTDOWN DISCONNECT PER CEC 690.12 <br />SYSTEM COMPLIANT WITH CEC 690.13 <br />СВ7 <br />2 <br />TO (E) <br />MDP A <br />TO (E) <br />MDP В <br />TO (E) <br />MDP С <br />150A/3P <br />705.13 PCS CONTROL SYSTEM. <br />SYSTEM TO BE LIMITED TO 100A CONTINUOUS VIA INVERTER SETTINGS. <br />SEE PV-7 FOR DETAILS. <br />CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS <br />ID CONDUCTOR RUN CONDUCTOR CONDUIT CURRENT-CARRYING <br />CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. <br />FACTOR <br />CONDUIT FILL <br />FACTOR <br />CONT. <br />CURRENT <br />MAX. <br />CURRENT <br />(125%) <br />BASE AMP.DERATED <br />AMP.TERM. TEMP. RATING AMP. @ TERMINAL LENGTH VOLTAGE VOLTAGE <br />DROP, V <br />VOLTAGE <br />DROP, % <br />1 INVERTER TO <br />JUNCTION BOX <br />10 AWG THWN-2 <br />COPPER, Y3 BUS CABLE FREE AIR -N/A 6 AWG BARE, COPPER 0.96 (32.6 °C)1 24A 30A 40A 38.4A 75°C 25A 45 FT.240V 1.94V 0.81% <br />2 JUNCTION BOX TO <br />AC LOAD CENTER 8 AWG THWN-2, COPPER 1'' DIA EMT 9 30A 10 AWG THWN-2, COPPER 0.96 (32.6 °C)0.8 24A 30A 55A 42.24A 75°C 50A 30 FT.240V 0.86V 0.36% <br />3 AC LOAD CENTER <br />TO SMART METER 1/O AWG THWN-2, COPPER 1.5'' DIA EMT 3 N/A 6 AWG THWN-2, COPPER 0.96 (32.6 °C)1 105.6A 132A 170A 163.2A 75°C 150A 10 FT.240V 0.24V 0.10% <br />4 <br />SMART METER <br />TO AC <br />DISCONNECT <br />1/O AWG THWN-2, COPPER 1.5'' DIA EMT 3 N/A 6 AWG THWN-2, COPPER 0.96 (32.6 °C)1 105.6A 132A 170A 163.2A 75°C 150A 10 FT.240V 0.24V 0.10% <br />5 AC DISCONNECT <br />TO TAP 1/O AWG THWN-2, COPPER 1.5'' DIA EMT 3 150A 6 AWG THWN-2, COPPER 0.96 (32.6 °C)1 105.6A 132A 170A 163.2A 75°C 150A 10 FT.240V 0.24V 0.10% <br />PV-4 <br />THREE LINE DIAGRAM <br />ENGINEER OF RECORD <br />DATE: 8.21.2023 <br />DESIGN BY: V.D. <br />CHECKED BY: D.A. <br />AZ-3320 <br />2007 S MAIN ST, <br /> SANTA ANA, CA 92707 <br />PAPER SIZE: 36" x 24" (ARCH D) <br />A B C D E F G H I J K L M N O <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />A B C D E F G H I J K L M N O <br />CONTRACTOR <br />E2SOL <br />PHONE: <br />LIC. NO.: <br />UNAUTHORIZED USE OF THIS <br />DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN <br />VIOLATION OF U.S. COPYRIGHT LAWS <br />AND WILL BE SUBJECT TO CIVIL <br />DAMAGES AND PROSECUTIONS. <br />P <br />P <br />NO. DESCRIPTION DATE <br />PROJECT <br />REVISION / RELEASE <br />SHEET NUMBER: <br />SHEET TITLE: <br />401-489-2273 <br />APN: 403-164-31 <br />REPC-134 <br />NEW PV SYSTEM: 39.150 kWp <br />Signed 1/10/2024 <br />INSPECTOR: Please verify that Inverters are <br />set to limit current as stated. <br />2007 S Main St - 101117244 & <br />20181345 <br />3/20/2024