Laserfiche WebLink
1. WALL MOUNTED SIGNAGE TO BE LOCATED ON THE LATCH SIDE OF DOOR CLEAR OF DOOR SWING. MOUNT <br />@ 48" MIN. TO THE BASELINE OF THE LOWEST LINE OF BRAILLE CELLS TO 60" MAX. A.F.F. TO THE BASELINE OF THE HIGHEST <br />LINE OF RAISED TEXT. . <br />2. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED <br />ON THE NEAREST ADJACENT WALL, PREFERRABLY AT THE RIGHT. <br />3. SIGNS MUST NOT BE INSTALLED BEHIND OBSTRUCTIONS AND READER MUST BE ABLE TO APPROACH SIGN WITHIN 3" <br />WITHOUT BEING HIT BY SWING OF DOOR <br />4. SIGN COLOR MUST CONTRAST AT 70% MIN. W/ BACKGROUNDS (DOOR OR WALL) <br />5. FOR LOCATION AND MOUNTING SEE A1.0 & A4.0 <br />CORROSPONDING <br />GRADE II BRAILLE <br />SHALL BE LOCATED <br />DIRECTLY UNDER <br />LETTER OR SYMBOL <br />INFO. <br />PLAN <br />CLEAR FLOOR SPACE <br />ELEVATION <br />HT. OF LETTERING <br />5 8" MIN. TO 2" MAX. <br />UPPERCASE LETTERSSIGN <br />MIRROR <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />TO <br /> <br />S <br />I <br />N <br />K <br /> <br />R <br />I <br />M <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />CL <br />R <br />. <br />19" MIN. <br />LINE OF FACE OF <br />CABINET BEYOND <br />INSULATE PIPES <br />25" <br />MAX. <br />FRONT APRON OF <br />COUNTER CABINET 6 <br />1 <br />/ <br />2 <br />" <br />SINK <br />1/4" MAX <br />ALLOWABLE <br />CLOSURE PRESSURE: <br />THRESHOLDS: <br />SIGNAGE, TYP. <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />12" <br />12" <br />2" <br />TACTILE SIGN <br />RESTROOM DOOR SIGN <br />SELF-LUMINOUS EXIT <br />SIGN, SEE ELEC. <br />1. CHARACTER TYPE: CHARACTERS ON SIGNS SHALL BE RAISED 132" (0.794MM) MIN. AND SHALL BE HELVETICA MEDIUM <br />UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE. <br />2. CHARACTER SIZE: RAISED CHARACTERS SHALL BE A MINIMUM OF 5 8" (15.9MM) AND A MAXIMUM OF 2" (51MM) HIGH. <br />3. FINISH AND CONTRAST: CONTRAST BETWEEN CHARACTERS, SYMBOLS AND THEIR BACKGROUND MUST BE 70% <br />MINIMUM AND HAVE A NON-GLARE FINISH. CBC 11B-703.5.1 <br />4.PROPORTION: CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 1:5 AND 1:10. CBC <br />11B-703.2 <br />ALL LETTER MEASURED MUST BE UPPERCASE. AFTER CHOOSING A TYPE TO TEST, BEGIN BY PRINTING THE LETTERS I, X, AND <br />0 AT 1" HIGH. PLACE A 1:1 SQUARE OVER THE X OR 0, WHICHEVER IS NARROWER, IF THE CHARACTER IS NOT WIDER THAN <br />1", NOR NARROWER THAN A 3:5 RECTANGLE, THE PROPORTIONS ARE CORRECT. USE A 1:5 RECTANGLE TO DETERMINE <br />OF THE STROKE OF THE I IS TOO BROAD, AND THE 1:10 RECTANGLE TO SEE IF IT IS TOO NARROW. IF THE TESTS ARE PASSED, <br />THE TYPE STYLE IS COMPLIANT WITH PROPORTION CODE. <br />1. ACCESSIBLE BUILDING ENTRANCES ARE REQUIRED TO BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND <br />ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. <br />2. PROVIDE SIGNS WITH INTERNATIONAL SYMBOL OF ACCESSIBILITY INDICATING LOCATION OF EACH ACCESSIBLE ENTRY <br />PROVIDE ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED. <br />3. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH <br />TO HEIGHT RATIO BETWEEN 1:5 AND 1:10. <br />4. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY <br />ARE TO BE READ, APPLICABLE TO OVERHEAD SIGNS <br />5. LETTERS AND NUMERALS SHALL BE RAISED 1/32", UPPER CASE, SANS SERIF OR SIMPLE SERIF TYPE AND SHALL BE <br />ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8" (16MM) HIGH, BUT NO HIGHER <br />THAN PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE <br />PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6" (152MM) MINIMUM IN HEIGHT. <br />6. THE CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL, MATTE, OR OTHER NON-GLARE FINISH. <br />CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND - EITHER LIGHT CHARACTERS ON A DARK <br />BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. <br />7. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL <br />ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, <br />INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT <br />SHALL BE 48" MIN. TO THE BASELINE OF THE LOWEST LINE OF BRAILLE CELLS TO 60" MAX. A.F.F. TO THE BASELINE OF THE <br />HIGHEST LINE OF RAISED TEXT. MOUNTING LOCATION FOR SUCH SIGNAGE SHALL BE SO THAT A PERSON MAY APPROACH <br />WITHIN 3" (76 MM) OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A <br />DOOR. <br />36 <br />" <br />36" <br />7 <br />A7.0 <br /> <br />SCALE: 3/4"=1'-0" <br />(TYP.) THE SURFACE OF EACH PARKING <br />SPACE FOR THE DISABLED IS REQUIRED TO <br />HAVE A 3 FOOT SQUARE "INTERNATIONAL <br />SYMBOL OF ACCESSIBILITY". THE <br />ACCESSIBILITY SYMBOL SHALL BE A STENCILED <br />WHITE FIGURE ON BLUE BACKGROUND <br />(COLOR #15090, FEDERAL STANDARD 595C). <br />FIGURE TO MATCH PROPORTIONS OF FIGURE <br />11B-703.7.2.1 <br />10 <br />A7.0 <br />ACCESSIBLE IDENTITY SIGNAGE <br />SCALE: NTS <br />1. ALL DOORWAYS TO HAVE 32" CLEAR ACCESS MINIMUM. <br />2. UNINTERRUPTED SPACE AT BOTTOM OF DOOR TO BE 10" EXCEPT <br />FOR AUTOMATIC DOORS. <br />3. NO REVOLVING DOOR ALLOWED FOR ACESSIBLE DOORS. <br />4. THRESHOLD MAX. HT.=1/2" WITH MAX. VERT. CHANGE OF 1/4". <br />5. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 <br />POUNDS FOR EXTERIOR DOORS, 5 POUNDS FOR INTERIOR DOORS, <br />AND 15 POUNDS FOR FIRE DOORS WITH DSA APPROVAL. <br />INTERIOR DOORS = 5 POUNDS <br />EXTERIOR DOORS = 5 POUNDS <br />FIRE DOORS = 15 POUNDS <br />COMPRESSED CARPET 1/4" MAX. <br />BELOW THRESHOLD <br />FINISH FLOOR LEVEL <br />THRESHOLD <br />1/2"MAX. AT <br />1:2 SLOPE <br />2'-10" TO 3'-8" A.F.F. <br />PUSH-PULLLEVER <br />DOOR/HANDLE <br />CLEARANCE <br />1 <br />2" MAX. <br />FOR LATCHING DOORS <br />1. OPERABLE FROM A SINGLE EFFORT, NO <br />GRASPING OR WRIST MOVEMENT(LEVERS, <br />PUSH-PULL OR PANIC DEVICES). <br />2. MOUNTED AT 34"-44" HIGH. PER 11B-404.2.7 <br />3. OPENABLE FROM INSIDE WITHOUT USE OF <br />KEY, SPECIAL KNOWLEDGE OR EFFORT. <br />1/2"MAX. <br />1/4"MAX. <br />DOOR NOTES <br />HARDWARE NOTES <br />2 <br />A7.0 <br />GENERAL STANDARDS FOR DOORS <br />SCALE: NTS <br />1. ACCESSIBLE SPACE MUST PERMIT USE OF EITHER OF THE CAR DOORS. <br />2. BUMPERS REQUIRED WHEN NO CURB OR BARRIER IS PROVIDED WHICH WILL PREVENT ENCROACHMENT OF CARS <br />OVER WALKWAYS. <br />3. WHEELCHAIR USERS MUST NOT BE FORCED TO GO BEHIND PARKED CARS OTHER THAN THEIR OWN. <br />4. WHEN ONLY ONE SPACE IS PROVIDED IT HAS TO BE 17 FT. WIDE TO PROVIDE A 9 FT. PARKING AREA AND A 8 FT. <br />LOADING AND UNLOADING AREA. <br />5. WHEN MORE THAN 1 SPACE IS REQUIRED, 2 SPACES CAN BE PROVIDED WITHIN A 26' WIDE AREA <br />6. EACH PARKING SPACE IS REQUIREDTO BE AT LEAST 18' LONG. <br />7. SURFACE SLOPES OF PARKING AREAS FOR THE DISABLED SHOULD BE MINIMAL, BUT ARE REQUIRED NOT TO EXCEED <br />1/4" PER FOOT SLOPE IN ANY DIRECTION. <br />8. RAMPS SHALL NOT ENCROACH INTO ANY PARKING SPACE. <br />9. ACCESSIBLE SPACE SHALL BE NEAR ACCESSIBLE PRIMARY ENTRANCE OF BUILDING. <br />10. ONE VAN ACCESSIBLE PARKING SPACE IS REQUIRED FOR EVERY 6 REQUIRED ACCESSIBLE SPACES WITH THE FIRST <br />REQUIRED ACCESSIBLE SPACE BEING VAN ACCESSIBLE. CBC 11B-208.2.4 <br />11. PROVIDE 114" MINIMUM VERTICLE CLEARANCE FOR VAN AND 98" FOR CAR PARKING AREAS. <br />12. LOADING ZONE SPACES SHALL HAVE A MINIMUM OF 9'-6" VERTICAL CLEARANCE. <br />13. NON-PARKING PASSENGER LOADING ZONES SHALL PROVIDE AN ACCESS AISLE AT LEAST 60" WIDE AND 20' LONG <br />ADJACENT AND PARALLEL TO THE VEHICLE PULL-UP SPACE. IF THERE ARE CURBS BETWEEN THE ACCESS AISLE ANE THE <br />VEHICLE PULL-UP SPACE, THEN A CURB RAMP SHALL BE PROVIDED. <br />14. EACH PARKING SPACE REQUIRED FOR THE DISABLED SHALL BE IDENTIFIED BY A SIGN. THE SIGN SHALL INCLUDE THE <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY. THE PARKING LOT SHALL HAVE A SIGN NOT LESS THAN 18" X 24" IN SIZE WITH <br />LETTERING NOT LESS THAN 1" HEIGHT. <br />15. THE WORDS "NO PARKING" SHALL BE PAINTED ON THE GROUND WITHIN EACH 5 FOOT LOADING/UNLOADING <br />ACCESS AISLE. THIS NOTICE SHALL BE PAINTED IN WHITE LETTERS NO LESS THAN 12" HIGH AND LOCATED SO THAT IT IS <br />VISIBLE TO TRAFFIC ENFORCEMENT OFFICIALS. <br />16. THE ACCESS AISLE SHALL BE MARKED BY A BORDER THAT IS PAINTED BLUE. WITHIN THAT BLUE BORDER, HATCHED <br />LINES SHALL BE A MAX. 36" O/C & SHALL BE PAINTED WITH A COLOR THAT CONTRASTS W/ THE PARKING SURFACE, <br />PREFERABLY BLUE OR WHITE. <br />PARKING NOTES <br />3 <br />A7.0 <br />GENERAL STANDARDS FOR ACCESSIBLE PARKING STALLS <br />SCALE: NTS <br />NEW ACCESSIBLE PARKING <br />SIGN TYP. 70" SQ. ON POLE <br />WALK 5'-0" MIN. OPTIONAL <br />18 <br />' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />9'-0" MIN. <br />SINGLE CAR <br />DOUBLE CAR <br />5'-0" (CARS) <br />8'-0" (VANS) <br />9'-0" MIN. <br />3'-0" ON CENTER, TYP. <br />TYPICAL SYMBOL <br />36" SQUARE PER <br />7A7.0 <br />TACTILE SIGNAGE NOTES <br />GENERAL SIGNAGE NOTES <br />NOTES <br />SINK NOTES <br />1. WHERE REQUIRED TO BE ACCESSIBLE, <br />PROVIDE A CLEAR SPACE 30"x48" IN FRONT <br />OF SINK. THE CLEAR SPACE MAY EXTEND <br />INTO KNEE AND TOE SPACE UNDER LAV. <br />2. INSULATE OR COVER ALL WATER AND <br />DRAIN PIPES UNDER SINK. <br />3. NO SHARP ABRASIVE SURFACES ARE <br />ALLOWED UNDER SINK. <br />4. FAUCET CONTROLS AND OPERATING <br />MECHANISMS ARE REQUIRED TO BE <br />OPERABLE WITH ONE HAND AND CANNOT <br />REQUIRE GRASPING, PINCHING, OR <br />TWISTING OF WRIST. THE FORCE REQUIRED <br />TO ACTIVATE CONTROLS IS NOT TO EXCEED <br />5 lbf. LEVER OPERATED, PUSH TYPE AND <br />ELECTRONICALLY CONTROLLED <br />MECHANISMS ARE EXAMPLES OF <br />ACCEPTABLE DESIGN. <br />5. SINK SHALL BE MAX 6 1/2" DEEP <br />6. SINK RIM MOUNTED MAX 34" AFF. KNEE <br />SPACE 27" HIGH BY 19" DEEP BY 30" WIDE <br />REQ'D. <br />7. KNEE AND TOE CLEARANCE PER CBC <br />11B-306 <br />4 <br />A7.0 <br />GENERAL STANDARDS FOR SINKS <br />SCALE: NTS <br />1. PROVIDE A CLEAR SPACE 30"x48" IN FRONT OF LAV. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE SPACE UNDER LAV. <br />2. INSULATE OR COVER ALL WATER AND DRAIN PIPES UNDER LAVATORIES. <br />3. NO SHARP ABRASIVE SURFACES ARE ALLOWED UNDER LAVATORIES. <br />4. FAUCET CONTROLS AND OPERATING MECHANISMS ARE REQUIRED TO BE OPERABLE WITH ONE HAND AND CANNOT REQUIRE GRASPING, <br />PINCHING, OR TWISTING OF WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS IS NOT TO EXCEED 5 lbf. LEVER OPERATED, PUSH TYPE AND <br />ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN. <br />6. SELF CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. <br />7. IF A MIN. 9" HEIGHT OF TO CLEARANCE IS PROVIDED, A MAX. OF 6" OF THE 48" OF CLEAR FLOOR SPACE REQUIRED AT THE FIXTURE MAY <br />EXTEND INTO THE TOE SPACE. <br />LAVATORY NOTES <br />8 <br />A7.0 <br />GENERAL STANDARDS FOR LAVATORIES <br />SCALE: 3/4"=1'-0" <br />BRACE <br />TO <br />WALL <br />INSULATE HOT & COLD WATER AND DRAIN PIPES <br />11 <br />A7.0 <br />DOME PAVER DETAIL <br />SCALE: 1-1/2"=1'-0" <br />INTERNATIONAL SYMBOL <br />OF ACCESSIBILITY <br />EXIT <br />ROUTE <br />12" <br />3 <br />8" <br />8" <br />EXIT ROUTE <br />14" THICK <br />8" <br />ACCESSIBLE <br />ROUTE <br />14" THICK <br />9" <br />MI <br />N <br />. <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />6" <br />MAX. <br />8" <br />MIN. <br />17" MIN. <br />17" MIN. <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />TO <br /> <br />C <br />/ <br />L <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />19" MAX. <br />48" MIN. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />2.3" TO 2.4" <br />APART 0.45" TO 0.47" AT TOP <br />0.9" TO 0.92" AT BTM. <br />0. <br />2 <br />" <br /> <br />H <br />T <br />. <br />TAPERED EDGES <br />WHERE EXPOSED <br />PROVIDE 12" X 12" CONTRASTING COLOR QUARRY-TILE <br />PRODUCT AS 'TERRAPAVER' MANUF. WAUSAU TILE CO. <br />(715) 359-3121 <br />DETECTABLE WARNINGS SHALL <br />COMPLY WITH CBC 11B-705.1. <br />ONLY DSA-AC DETECTABLE <br />WARNING PRODUCTS ARE INSTALLED. <br />2.3" TO 2.4" <br />APART <br />CL CL CL <br />TILE JOINT <br />CONTRAST COLOR (PER CBC 11B-705.1.1.3): <br />YELLOW PER FS 33538 <br />1 <br />2 <br />2. <br />3 <br />5 <br />" <br />CL CL <br />CL CL <br />3"3" <br />3" <br />3" <br />8" MIN. <br />11" MIN. <br />19" MIN. <br />9" <br /> <br />M <br />I <br />N <br />. <br />NO PARKING <br />9"9" <br />MIN. 0.65" BASE SPACING <br />MAXIMUM <br />OCCUPANCY <br />14" THICK <br />### <br />MAXIMUM <br />OCCUPANCY <br />8" <br />12" <br />ALL-GENDER <br />14" THICK <br />GRAB BAR <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />1 1/2"1 1/2" <br />1 1/4" <br />TO <br />1. LOCATE GRAB BARS ON EACH SIDE OR ON ONE SIDE AND IN BACK OF TOILET, 33" TO 36" ABOVE AND PARALLEL TO <br />FLOOR TO TOP OF GRIPPING SURFACE. BARS AT SIDE TO BE 42" LONG. BARS IN BACK TO BE MIN. 36" LONG. <br />2. DIAMETER OR WIDTH OF GRIPPING SURFACE IS REQUIRED TO BE TO 1 1/2" OR SHAPE IS TO PROVIDE AN EQUIVALENT <br />GRIPPING SURFACE. <br />IF GRAB BARS ARE MOUNTED ADJACENT TO WALL, THE SPACE BETWEEN WALL AND BAR IS TO BE 1 1/2". <br />3. GRAB BARS SHALL NOT ROTATE IN THEIR FITTINGS. <br />4. GRAB BARS AND MOUNTINGS SHALL WITHSTAND 250 LBS. POINT LOAD. <br />1. WHERE TOWEL, SANITARY NAPKIN AND WASTE RECEPTACLES AND SIMILAR DISPENSING <br />AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH TYPE IS TO BE LOCATED <br />WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROM THE FLOOR. <br />2. MOUNT MIRRORS WITH BOTTOM OF REFLECTIVE SURFACE EDGE NO MORE THAN 40" <br />FROM FLOOR. <br />3. LOCATE TOILET TISSUE DISPENSERS ON WALL 7" TO 9" FROM FRONT EDGE OF TOILET <br />SEAT AND 19" MIN. AFF. <br />TOILET ACCESSORIES <br />GRAB BARS <br />ACCESSIBILITY COMPLIANCE NOTES <br />1 <br />A7.0 <br />GENERAL STANDARDS FOR TOILET ACCESSORIES <br />SCALE: NTS <br />TOILET <br />33" TO 36" <br />TO TOP OF <br />GRIPPING <br />SURFACE <br />CL <br />3'-0" <br />1'-0"2'-0" <br />1. ACCESSIBLE SIGNAGE PER CBC 11B-703 & 11B-604.8.2.2 SHALL BE PROVIDED AT TOILET FACILITIES. SIGNS TO HAVE <br />RAISED LETTERS PLUS BRAILLE, AND ARE TO BE INSTALLED 48" MIN. AFF OR GROUND SURFACE, MEASURED FROM THE <br />BASELINE OF THE LOWEST BRAILLE CELLS AND 60" MAX. AFF OR GROUND SURFACE, MEASURED FROM THE BASELINE OF <br />THE HIGHEST LINE OF RAISED CHARACTERS. SIGN SHALL BE LOCATED ADJACENT TO LATCH SIDE OF DOOR. <br />2. ALL DOORS SHALL COMPLY WITH CBC 1007, 1010, 11B-206.5, AND 11B-404, AS APPLICABLE. DOOR HARDWARE SHALL <br />BE LEVER OR PUSH TYPE, MOUNTED 34" TO 44" ABOVE THE FLOOR, PER CBC 11B-404.2.7. ALL DOORS SHALL BE 3'-0" WIDE, <br />PER CBC 11B-404.2.3. <br />3. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR <br />INTERIOR DOORS. SUCH PUSH OR PULL EFFORT SHALL BE APPLIED AT RIGHT ANGLES TO HINGED DOORS. AT REQUIRED <br />FIRE DOORS, MAX. OPERATING EFFORT MAY BE INCREASED TO 15 LBS. <br />4. PER CBC 11B-302 & 11B-404.2.5, REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A LEVEL FLOOR OR LANDING <br />ON EACH SIDE OF THE DOOR. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2" LOWER THAN THE THRESHOLD OR <br />THE DOORWAY. <br />5. THE LOWER 10" OF ALL DOORS SHALL BE SMOOTH AND UNINTERRUPTED TO ALLOW THE DOOR TO BE OPENED BY A <br />WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. <br />6. TELEPHONES SHALL BE HEARING AID COMPATIBLE WITH VOLUME CONTROLS CAPABLE OF MIN. 12 DBA / MAX 18 DBA <br />ABOVE NORMAL. PROVIDE PUSH-BUTTON CONTROLS AND MIN. 29" CORD TO HANDSET. <br />7. SINKS AND LAVATORIES SHALL COMPLY WITH ADA SEC. 4.19 AND THE FOLLOWING: <br />a) A MINIMUM OF 30" x 48" CLEAR SPACE SHALL BE PROVIDED IN FRONT OF THE LAVATORY . <br />b) THE CLEAR SPACE BENEATH LAVATORIES SHALL BE A MINIMUM OF 29" HIGH x 30" WIDE x 8" DEEP AT THE TOP <br />AND 9" HIGH x 30" WIDE x 17" DEEP AT THE BOTTOM. THE MAXIMUM HEIGHT OF THE BASIN / COUNTER TOP SHALL BE <br />34" HEIGHT MAX. <br />c) ALL WATER AND DRAIN PIPES UNDER THE LAVATORY SHALL BE INSULATED. <br />d) FAUCET CONTROLS SHALL HAVE AN OPERATING FORCE OF NOT GREATER THAN 5 POUNDS. <br />8. ALL FLOORS TO BE SLIP-RESISTANT. <br />9. CHANGES IN LEVEL: CHANGES IN LEVEL OF 1 <br />4" HIGH MAXIMUM SHALL BE PERMITTED TO BE VERTICAL AND WITHOUT <br />EDGE TREATMENT. CHANGES IN LEVEL BETWEEN 1 <br />4" HIGH MIN. AND 1 <br />2" HIGH MAX. SHALL BE BEVELED WITH A SLOPE NOT <br />STEEPER THAN 1:2. CHANGES IN LEVEL GREATER THEN 1 <br />2" HIGH SHALL BE RAMPED, AND SHALL COMPLY WITH SECTION <br />11B-405 OR 11B-406 (CBC 11B-303) <br />PLAN <br />60 <br />" <br />MI <br />N <br />. <br />ELEVATION <br />24 <br />" <br />MI <br />N <br />18" <br />MIN. <br />17"- <br />18" <br />1. SUFFICIENT SPACE IS REQUIRED IN TOILET ROOM FOR A WHEELCHAIR MEASURING 30" WIDE BY 48" LONG TO ENTER ROOM AND PERMIT DOOR <br />TO CLOSE. <br />2. WHEN THE DOOR IS LOCATED IN CORRIDOR SIDEWALL AND SWINGS INTO CORRIDOR, MIN. WIDTH OF CORRIDOR SHALL BE 60" UNLESS OTHER <br />STATE OR LOCAL BUILDING CODES ALLOW LESSER CORRIDOR WIDTH. <br />3. ALL TOILETS TO HAVE FLUSH HANDLES ON WHEELCHAIR ACCESS SIDE (INCLUDING TANK TOILETS) <br />4. FLUSH CONTROL SHALL BE AN OSILLATING HANDLE WITH MAX. 3 lbs. OPERATING FORCE, ELECTRIC OPERATION OR APPROVED EQUAL. <br />5. TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL 7" TO 9" FROM THE FRONT EDGE OF THE TOILET SEAT, AND HAVE CONTINUOUS <br />PAPER FLOW. <br />6. FORWARD APPROACH - MANEUVERING CLEARANCE SHALL BE PROVIDED FOR ALCOVE, MIN. 36" WIDE WHERE DEPTH EXCEEDS 24". - PER CBC <br />11B-305.7.1 <br />TOILET NOTES <br />PRIVACY LOCK DOOR <br />32" MIN. CLEAR <br />FLUSH CONTROL LOCATED ON <br />WIDE SIDE OF TOILET MAX 44" AFF <br />36" MIN. GRAB BAR <br />42" MIN GRAB BAR <br />ROLL PAPER HOLDER <br />60"CL. <br />5 <br />A7.0 <br />ACCESSIBLE SINGLE OCC. TOILET <br />SCALE: 3/4"=1'-0" <br />42" MIN. <br />GRAB BAR12" MAX. <br />33 <br />" <br /> <br />M <br />I <br />N <br /> <br />- <br /> <br />3 <br />6 <br />" <br /> <br />M <br />A <br />X <br />A. <br />F <br />. <br />F <br />. <br /> <br />T <br />O <br />P <br /> <br />O <br />F <br />GR <br />I <br />P <br /> <br />S <br />U <br />R <br />F <br />A <br />C <br />E <br />17 <br />" <br />- <br />1 <br />9 <br />" <br />7"-9" <br />54" MIN. <br />60" <br />MIN. <br />19 <br />" <br />MI <br />N <br />. <br />56 <br />" <br /> <br />M <br />I <br />N <br />. <br />MATERIALPRODUCTTRADENAMEMODELNUMBER <br />6 <br />A7.0 <br />ACCESSIBLE PARKING AUTHORIZATION SIGN <br />SCALE: 3/4"=1'-0" <br />9 <br />A7.0 <br />ACCESSIBLE PARKING STALL SIGN <br />SCALE: 3/4"=1'-0" <br />36 <br />" <br />36 <br />" <br />NOTE: <br />SIGNS SHALL BE PORCELAIN <br />ON STEEL W/ REFLECTORIZED <br />BEADED TEXT.12" <br />12" <br />NOTE: <br />SIGNS SHALL BE PORCELAIN ON STEEL <br />W/ REFLECTORIZED BEADED TEXT. <br />VAN ACCESSIBLE SIGN <br />WHITE SYMBOL & <br />LETTERING ON <br />BLUE BACKGROUND <br />H/C PARKING SIGN <br />2X2 STL. OR ALUM. <br />TUBE PRIME AND PAINT <br />2 COATS FLAT BLACK <br />FINE SIGNAGE <br />2-1/4" DIA. STANLESS <br />SELF-TAPPING <br />SCREWS OR BOLTS <br />AT EACH SIGN,TYP. <br />80 <br />" <br />MIN. SIGN <br />AREA 70 SQ. <br />INCHES <br />18 <br />" <br />FINISH GRADE <br />GALV. STL. TUBE <br />SLEEVE <br />ACCESSIBLE <br />VAN <br />MINIMUM <br />FINE $250 <br />12 <br />" <br />3" <br />12" <br />1" HIGH LETTERING W/ THE <br />FOLLOWING MESSAGE: <br />UNAUTHORIZED VEHICLES PARKED <br />IN DESIGNATED ACCESSIBLE <br />SPACES NOT DISPLAYING <br />DISTINGUISHING PLACARDS OR <br />SPECIAL LICENSE PLATES ISSUED FOR <br />PERSONS WITH DISABILITIES <br />WILL BE TOWED AWAY AT OWNER'S <br />EXPENSE. TOWED VEHICLES MAY <br />BE RECLAIMED BY TELEPHONING <br />THE POLICE DEPARTMENT: <br />(714) 245-8665 <br />17" <br />3" <br />GALV. STL. TUBE <br />SLEEVE <br />2X3 STL. OR ALUM. <br />TUBE PRIME AND PAINT <br />2 COATS FLAT BLACK <br />22 <br />" <br />12 <br />" <br />80 <br />" <br />6" <br />FINISH GRADE <br />EXIT <br />12" <br />3 <br />8" <br />8" <br />EXIT <br />14" THICK <br />EXIT <br />EXIT <br />ROUTE <br />SIGNAGE LOCATION, TYP. <br />17 <br />" <br /> <br />T <br />O <br /> <br />1 <br />9 <br />" <br />DE <br />P <br />T <br />H <br />ASSISTIVE <br />LISTENING <br />SYSTEMS <br />AVAILABLE <br />ASSISTIVE LISTENING <br />SYSTEMS <br />14" THICK <br />12"SHEET NO. <br />2402 <br />REVISIONS: <br />4/12/2024DATE: <br />PROJECT NO. <br />PERMIT NO. <br />Dr <br />. <br /> <br />B <br />e <br />s <br />h <br />a <br />i <br /> <br />A <br />S <br />C <br />20 <br />1 <br />0 <br /> <br />E <br />. <br /> <br />1 <br />s <br />t <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />, <br /> <br />S <br />t <br />e <br />. <br /> <br />2 <br />0 <br />0 <br /> <br />& <br /> <br />2 <br />1 <br />0 <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />Ne <br />w <br /> <br />A <br />m <br />b <br />u <br />l <br />a <br />t <br />o <br />r <br />y <br /> <br />C <br />a <br />r <br />e <br /> <br />F <br />a <br />c <br />i <br />l <br />i <br />t <br />y <br /> <br />T <br />e <br />n <br />a <br />n <br />t <br /> <br />I <br />m <br />p <br />r <br />o <br />v <br />e <br />m <br />e <br />n <br />t <br />A-7.0 <br />DETAILS <br />ACCESSIBILITY <br />2010 E First St Units #200 <br />& 2102/19/2025