Laserfiche WebLink
2 <br />TYP. <br />3 4 <br />5 6 7 <br />8 9 10 <br />20 <br />TYP. <br />20 <br />TYP. <br />20 <br />TYP. <br />10 <br />10 <br />10 <br />10 <br />10 <br />10 <br />16 <br />16 <br />16 <br />11 13 19 <br />A-1.2 <br />SHEET NO. <br />2402 <br />REVISIONS: <br />4/12/2024DATE: <br />PROJECT NO. <br />PERMIT NO. <br />Dr <br />. <br /> <br />B <br />e <br />s <br />h <br />a <br />i <br /> <br />A <br />S <br />C <br />20 <br />1 <br />0 <br /> <br />E <br />. <br /> <br />1 <br />s <br />t <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />, <br /> <br />S <br />t <br />e <br />. <br /> <br />2 <br />0 <br />0 <br /> <br />& <br /> <br />2 <br />1 <br />0 <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />Ne <br />w <br /> <br />A <br />m <br />b <br />u <br />l <br />a <br />t <br />o <br />r <br />y <br /> <br />C <br />a <br />r <br />e <br /> <br />F <br />a <br />c <br />i <br />l <br />i <br />t <br />y <br /> <br />T <br />e <br />n <br />a <br />n <br />t <br /> <br />I <br />m <br />p <br />r <br />o <br />v <br />e <br />m <br />e <br />n <br />t <br />10/31/25 <br />REN. DATE <br /> C-26955 <br />OIF <br />NRI <br />LOFCA <br />SAUNDERS <br />TATS <br />E <br />CETIHCADESRCILEN <br />NIALL F. <br />A <br />T <br />3/16" = 1'-0" <br />DEMOLITION PLAN <br />1.2 <br />A <br />N <br />DEMOLITION <br />PLAN <br />DEMOLITION PLAN KEYNOTES <br />1.CARRY OUT ALL DEMOLITION WORK INDICATED IN ACCORDANCE WITH STATE AND LOCAL CODES. CARRY OUT WORK <br />DURING TIMES PERMITTED BY AND THE LOCAL AUTHORITITES AND INFORM ADJACENT PROPERTIES OF TIMES SCHEDULED <br />FOR NOISY WORK OR ANY INTERRUPTION IN UTILITIES OR SERVICES. KEEP NUSANCE TO A MINIMUM. <br />2.ALL FIXTURES, FURNISHINGS AND FINISHES SHOWN ARE TO BE REMOVED, UNLESS EXPRESSLY NOTED HEREIN. <br />3.REMOVE ALL DEBRIS FROM SITE AS WORK PROCEEDS AND DISPOSE OF PER CODE AND THE LOCAL CODE <br />REQUIREMENTS. INFORM ARCHITECT IMMEDIATELY IF ANY HAZARDOUS MATERIALS ARE FOUND TO BE PRESENT. <br />4.PATCH AND REPAIR ANY DAMAGE THAT OCCURS TO THE EXISTING BUILDING WHICH ARE NOT INDICATED TO BE <br />ALTERED OR DEMOLISHED. <br />5.EXISTING INTERIOR TENANT PARTITIONS AS NOTED WITHIN EXISTING SUITE TO BE REMOVED. ONLY NON-LOAD BEARING <br />WALLS TO BE DEMOLISHED. <br />6.REMOVE EXISTING INTERIOR SUSPENDED CEILINGS, SOFFITS, FIXTURES, FURNISHINGS, LIGHTING, FACE FRAMING, FINISHES <br />AND GLAZING, AS INDICATED. SUSPENDED CEILING IN NON-DEMOLISHED AREA TO REMAIN - SEE FLOOR PLAN A1.0. <br />7.REMOVE ALL EXISTING WALL / FLOOR FINISHES WITHIN SUBJECT LEASE SPACE. REMOVE ALL INTERIOR TILE, CARPET, AND <br />VINYL FLOORING. <br />8.PATCH AND REPAIR ANY PITS OR HOLES IN FLOOR ASSEMBLY AS REQUIRED. COORD. W/ TENANT BELOW ONLY WHERE <br />NEEDED TO ACCOMODATE NEW UTILITIES (COORD. W/ EXISTING STRUCTURE). <br />9.REMOVE EXISTING INTERIOR DOORS AND FRAMES, FLOOR FIXTURES, FIXTURES, EQUIPMENT AND CABINETS AS <br />INDICATED. <br />10.REMOVE EXISTING PLUMBING FIXTURES AND SPECIALTIES. CAP WATER / SEWER AND LEAVE READY FOR CONNECTION <br />OF NEW FIXTURES. <br />11.REMOVE ALL ELECTRICAL OUTLETS IN WALLS TO BE REMOVED. REMOVE ANY SURFACE RUN CONDUIT OR ABANDONED <br />ELECTRICAL OUTLETS. DO NOT REMOVE TELEPHONE AND CABLE TV UTILITY SERVING SITE. <br />12.MAIN ELECTRICAL PANEL AND BREAKERS TO BE REPLACED (SEE ELECTRICAL PLANS). DO NOT REMOVE UNTIL VERIFIED. <br />ARRANGE FOR TEMPORARY POWER UNTIL NEW WORK IS COMPLETED AND READY FOR IMMEDIATE CONNECTION. <br />EXISTING DISCONNECT TO BE RELOCATED ON NEW WALL ADJACENT. <br />13.REMOVE ALL EXISTING INTERIOR SIGNS, INCLUDING WINDOW SIGNS. <br />14.ENSURE ALL EXISTING CEILING MOUNTED HVAC DUCTWORK AND HANGERS ARE REMOVED. CONFIRM ROOFTOP HVAC <br />EQUIPMENT. TO BE REMOVED/REPLACED. SEE HVAC PLANS. <br />15.PROTECT IN PLACE EXIST. BUILDING WALLS/FINISHED NOT SLATED FOR DEMO. PROTECT EXISTING DEMISING WALLS <br />(REPAIR), STRUCTURAL POSTS AND BEAMS. <br />16.REMOVE EXISTING STOREFRONT ASSEMBLY & PREP FOR NEW STOREFRONT DOOR/WINDOWS - THIS AREA ONLY. <br />REWORK STOREFRONT IN EXIST. DOOR LOCN. <br />17.INFORM ARCHITECT IMMEDIATELY OF ANY UN-RESOLVABLE CONFLICTS. <br />18.ALL UTILITIES TO BE CAPPED OFF PRIOR TO DEMOLITION. <br />19.EXISTING EINTERIOR DOORS, FRAMES & SIDELIGHT WINDOWS AS INDICATED TO REMAIN. PROTECT IN PLACE. <br />PATCH/REPAIR/REPLACE AS NEEDED. <br />20.EXISTING STRUCT. COLUMNS TO REMAIN. PROTECT IN PLACE. <br />21.EXISTING DEMISING WALL DOORS TO BE REMOVED AND PREPPED FOR INFILL. <br />WALL LEGEND <br />WALLS/HARDSCAPE/FIXTURES TO BE DEMOLISHED <br />EXISTING WALLS/HARDSCAPE/FIXTURES TO REMAIN <br />2010 E First St Units #200 <br />& 2102/19/2025