Laserfiche WebLink
S <br />O <br />V <br />V <br />V <br />S <br />O <br />V <br />V <br />V <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />OVVVOVVVOVVV <br />19 TYP. <br />5 TYP. <br />6 TYP. <br />4 <br />8 TYP. <br />11 TYP. <br />15 <br />182081119415 <br />13 TYP. <br />18 <br />13 TYP. <br />9 TYP. <br />19 51071 <br />7 <br />1 <br />20 <br />20 <br />7 <br />16 <br />10 <br />24 <br />20 <br />1413 <br />5 <br />107 <br />6 <br />5 <br />19 <br />18 <br />20 <br />TYP. <br />TYP. <br />TYP. <br />TYP. <br />TYP.TYP.TYP.TYP.TYP. <br />23 <br />23 <br />1 <br />9 <br />TYP. <br />TYP. <br />TYP. <br />TYP. <br />19 <br />4 <br />2 <br />2 <br />3 <br />3 <br />3 3 <br />3 <br />3 <br />33 <br />3 <br />3 3 <br />3 <br />33 <br />3 <br />1 <br />2 <br />3 <br />3 <br />2 <br />3 <br />9 TYP.18 <br />20 <br />3 <br />3 <br />3 <br />3 <br />2 <br />25 <br />24 <br />10 <br />24 <br />18 <br />20 <br />26 <br />10 <br />3 <br />27 <br />A-2.0 <br />SHEET NO. <br />2402 <br />REVISIONS: <br />4/12/2024DATE: <br />PROJECT NO. <br />PERMIT NO. <br />Dr <br />. <br /> <br />B <br />e <br />s <br />h <br />a <br />i <br /> <br />A <br />S <br />C <br />20 <br />1 <br />0 <br /> <br />E <br />. <br /> <br />1 <br />s <br />t <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />, <br /> <br />S <br />t <br />e <br />. <br /> <br />2 <br />0 <br />0 <br /> <br />& <br /> <br />2 <br />1 <br />0 <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />Ne <br />w <br /> <br />A <br />m <br />b <br />u <br />l <br />a <br />t <br />o <br />r <br />y <br /> <br />C <br />a <br />r <br />e <br /> <br />F <br />a <br />c <br />i <br />l <br />i <br />t <br />y <br /> <br />T <br />e <br />n <br />a <br />n <br />t <br /> <br />I <br />m <br />p <br />r <br />o <br />v <br />e <br />m <br />e <br />n <br />t <br />10/31/25 <br />REN. DATE <br /> C-26955 <br />OIF <br />NRI <br />LOFCA <br />SAUNDERS <br />TATS <br />E <br />CETIHCADESRCILEN <br />NIALL F. <br />A <br />T <br />1/4" = 1'-0" <br />REFLECTED CEILING PLAN <br />2.0 <br />A <br />N <br />REFLECTED <br />CEILING PLAN <br />4 <br />A6.0 <br />CEILING PLAN KEYNOTES <br />1.COORDINATE REFLECTED CEILING INSTALLATION WITH MECHANICAL AND ELECTRICAL REQUIREMENTS - SEE E-SERIES & <br />M-SERIES DWGS. VERIFY ALL HVAC DIFUSER LOCATIONS IN FIELD. <br />2. CEILINGS INDICATED AS GYP. BD. TO BE 5/8" TYPE 'X' WITH SMOOTH WASHABLE PAINTED FINISH. ATTACHED GYPSUM <br />BOARD TO MTL. STUD JOISTS AT 16" O.C. STUD JOISTS TO SPAN SHORTEST DIST. BETWEEN ADJ. WALLS IN EA. CASE. <br />3. INTERIOR CEILING HEIGHTS VARY - SEE SHEET NOTE ABOVE, AND FINISH SCHEDULE. <br />4. DO NOT SCALE FROM PLANS. FIELD VERIFY ALL DIMENSIONS & REPORT ANY DISCREPANCIES TO ARCHITECT AT ONCE. <br />5.EXIT SIGNS TO BE INTERNALLY ILLUM. AND PROVIDED W/ BATTERY BACK-UP OF MIN. 1 -1/2 HOURS DURATION IN CASE OF <br />PRIMARY POWER LOSS. <br />6.PROVIDE MIN. 1 FOOT-CANDLE ILLUM. IN ALL OCCUPIED AREAS OF THE BUILDING AND EGRESS ROUTES. <br />GENERAL NOTES <br />1.NEW SUSPENDED T-BAR CEILING SYSTEM: ARMSTRONG SEISMIC RX HEAVY DUTY - SUPRAFINE XL 7500 9/16" TEESERIES <br />W/24"x24" (SEE PLAN) ASTRO-CLIMA ACOUSTIC LAY-IN TILES. PROVIDE WASHABLE TILES IN LOCATIONS SELECTED BY <br />OWNER - SEE DETAIL 6A6.0 AND 7A6.0 <br />2.NEW SUSPENDED DRYWALL CEILING SYSTEM: USG DRYWALL SUSPENSION SYSTEM. SEE DETAIL 6A6.0 AND 7A6.0 <br />3.NEW GYP. BD. CEILING W/ SMOOTH TEXTURE FINISH: GYP. BD. CEILING: 5/8" TYPE 'X' GYPSUM BOARD ON 2X 20 GA. <br />MTL. JOIST STUDS 16" O.C. W/ BLK'G. / BRACING AS - CEILING HEIGHTS AS NOTED BELOW. SEMIGLOSS SHEEN <br />WASHABLE PAINT. <br />4.NEW FULLY DIMMABLE CLEANROOM 6" LED DOWNLIGHT W/ FULLY SEALED/GASKETED HOUSING AND FLUSH FROSTED <br />GLASS LENSE, PHILIPS CLEANROOM LED CR250B OR EQUIV. PROVIDE SEPARATE DIMMABLE CONTROL ZONES AS <br />NOTED. FIXTURES/ZONES IN THIS AREA ONLY. <br />5.NEW 6" LED DOWNLIGHT W/ GLASS LENS AND DECORATIVE TRIM (DIMMER CONTROL) TYP. - SEE ELEC. <br />6.NEW DECORATIVE VANITY LIGHTS - SET ON WALL AT 80" AFF CENTERED (ABOVE LAV. BASIN ETC.) OR @ EA. SIDE OF <br />MIRROR. SEE ELEC. <br />7.NEW EDGE-ILLUM. EXIT SIGN (EXIT DOORWAYS, ETC.). PROVIDE UNIT W/ 90 MINUTE BATTERY BACK-UP - SEE ELEC. <br />8.2'x2'/4' FLUSH PANEL LIGHT FIXTURES W/ WASHABLE LENS - SEE ELEC. FIXTURE SCHEDULE <br />9.2'x2'/4' FLUSH PANEL LIGHT FIXTURES W/ INDIRECT SHIELDING SEE ELEC. FIXTURE SCHEDULE <br />10.4" SQUARE TRIMLESS LED DOWNLIGHT - LITHONIA LDN4 SQ. SERIES OR EQ. <br />11.PROVIDE STRUCTURAL BACKING FOR OWNER-SUPPLIED EXAM LIGHT - COORD. W/ MANU. SWITCH CONTROL. <br />12.PROVIDE MANUAL OPERATED ROLLER SHADES AT ALL EXTERIOR WINDOWS AS NECESSARY. <br />13.CONNECT NEW NURSE CALL SIGNAL LIGHTS TO PULL STATIONS AND OWNER-SUPPLIED CENTRAL NURSE CALL <br />ANNUNCIATOR. <br />14.NEW RECOVERY CUBICLE CURTAIN TRACK: CURTAINS 12" ABOVE FFL TO FULL HT. CEILING. SEE DETAIL 9A6.2 <br />15.NEW MEDICAL GAS VALVES W/ CEILING DROPS (VACUUM, WAG, OXY AND N20) - SEE PLUMB. <br />16.NEW 32.3" DIA. DECORATIVE LED CHANDELIER (BUBBLES BRASS RING CHANDELIER BY VAKKERLIGHT ) - COORD. W/ <br />ELEC. - ALL PENDANT FIXTURES TO BE HUNG PER MANUF. DIRECTIONS. <br />17.PROVIDE 4" SOUND INSULATION BLANKETS OVER THE TOP OF WALLS - TYP. ALL WALLS OF RECOVERY <br />18.LED TASK LIGHTING - CONT. UNDER CABINET STRIP FIXTURES - FULL WIDTH OF CABS. IN LOCNS. SHOWN <br />19.CONNECT TO EXHAUST DUCT VENTED TO EXTERIOR. <br />20.NEW COVED GYP. BD. SOFFIT W/ PERIM. LED LIGHTING, LEDI INSPIRE VA NUDE SERIES TAPE LIGHT OR EQUIV. AT HT. <br />NOTED ON PLAN. PROVIDE 12" DEEP COVE <br />21.LINE OF UPPER WALL CAB. - TYP. <br />22.PROVIDE WASHABLE SEALED TILES IN THE FOLLOWING ROOMS: #209 CLEAN UTILITY, #208 SOILED UTILITY <br />23.EXISTING SUSPENDED T-BAR CEILING SYSTEM IN AREAS INDICATED WITH HATCH TO REMAIN, PATCH/REPAIR AS <br />NECESSARY- REPLACE EXISTING FLORESCENT LIGHT FIXTURES IN THIS AREA WITH LED FIXTURES. <br />24.SURFACE MOUNTED WOOD PANELING IN 3" RECESSED GYP. BD. CEILING. SOFFIT - PRODUCT & FINISH TBD. BY INTERIOR <br />DESIGNER <br />25.NEW 47.2"X18.9" DECORATIVE LED CHANDELIER (GINGKO CHANDELIER S BY VAKKERLIGHT ) - COORD. W/ ELEC. - ALL <br />PENDANT FIXTURES TO BE HUNG PER MANUF. DIRECTIONS. <br />26.NEW 31.5"X11.8" DECORATIVE LED CHANDELIER (GINGKO CHANDELIER H BY VAKKERLIGHT ) - COORD. W/ ELEC. - ALL <br />PENDANT FIXTURES TO BE HUNG PER MANUF. DIRECTIONS. <br />27.NEW 7.5" DIAM. DECORATIVE LED PENDANT FIXTURE (TITAN GLASS PENDANT LAMP BY VAKKERLIGHT ) - COORD. W/ <br />ELEC. - ALL PENDANT FIXTURES TO BE HUNG PER MANUF. DIRECTIONS. <br />ACCESS PANEL: <br />FOR CEILING ACCESS PANEL SEE 0A7.0 <br />FOR ROOF HATCH SEE 0A7.0 <br />MECHANICAL REGISTERS: <br />REFER TO MECHANICAL DRAWINGS FOR FIXTURE TYPES <br />LIGHT FIXTURES ETC. (REFER TO ELECTRICAL DWGS: <br />ILLUMINATED EXIT SIGNS (W/ 90 MIN. BATTERY BACKUP) <br />2'X4' RECESSED LED PARABOLIC <br />2'X4' RECESSED LED INDIRECT W/ PERF. MTL. SHIELD <br />2'X4' RECESSED LED W/ PLASTIC PRISMATIC LENS <br />(SEALED CLEAN ROOM FIXTURES IN OP ROOMS) <br />RECESSED LED DOWNLIGHT (W/ LENS IN OP ROOM) <br />LED UNDER-CABINET TASK LIGHT (ALKO OR EQ.) <br />CEILING SPEAKERS (W/ SEP. VOL. CONTROL) <br />LED WALL SCONCE / VANITY LIGHT AT 84" AFF <br />CONCEALED LED LED TAPE LIGHT - CONTINUOUS <br />CEILING LEGEND <br />NOTE: <br />ELECTRICALLY POWERED, SELF-LUMINOUS AND <br />PHOTO LUMINESCENT EXIT SIGNS SHALL BE <br />LISTED AND LABELED IN ACCORDANCE WITH UL <br />924 AND SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE MANUFACTURERS INSTRUCTIONS AND <br />CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED <br />AT ALL TIMES. CBC 1011.4 <br />CEILING HEIGHTS <br />CEILING ACCESSORIES <br />(REFER TO ELECTRICAL DRAWINGS) <br />CEILING SPEAKERS <br />(W/ SEPARATE VOLUME CONTROL) <br />CABLE TV OUTLET <br />NURSE CALL LIGHT <br />SMOKE/FIRE ALARM: HORN/STROBE LIT <br />DRYWALL CEILING ACCESS HATCH <br />(GASKETTED AT STERILE ROOMS)H <br />SP <br />TV <br />S <br />SP <br />2 9'-11" <br />N <br />O <br />V <br />V <br />V <br />S <br />MEDICAL GAS OUTLETS <br />SCAVENGING (WAG) - VACUUM <br />VACUUM <br />VACUUM <br />VACUUM <br />OXYGEN <br />NITROUS OXIDE <br />MEDICAL CO2 INSUFFLATION GASC <br />ALL CEILING HEIGHTS SUBJECT TO FIELD VERIFICATION <br />3 10'-0" <br />1 9'-0" <br />6 <br />A6.0 <br />7 <br />A6.0 <br />6 <br />A6.0 <br />7 <br />A6.0 <br />4 <br />A6.2 <br />4 <br />A6.2 <br />8 <br />A6.0 <br />8 <br />A6.0 <br />4 <br />A6.0 <br />12 <br />A6.0 <br />9 <br />A6.2 <br />5 <br />A6.2 <br />8 <br />A6.2 <br />8 <br />A6.2 <br />A BUILDING REVIEW <br />REVISIONS 11-21-24 <br />2010 E First St Units #200 <br />& 2102/19/2025