Laserfiche WebLink
REV: B <br />AHJ: CA-CITY OF SANTA ANA <br />33.712210, -117.895724 <br />APN: 412-39-308 <br />NAME: DIEN NGUYEN <br />DRAFTED BY: ARUNDEEPAN R <br />ADDRESS: 2009 W ADAMS ST, <br />SANTA ANA, CA 92704 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-75621 <br />PAPER SIZE: 17"X11"SHEET: CS-01DATE: 04/20/2023 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: SURYA PRAKASH P <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA 92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br /> David Bingwen Hsu <br /> David Bingwen Hsu, Lic. Holder <br />AERIAL MAP VICINITY MAP <br />HOUSE VIEW <br />COVER SHEET <br />DIEN NGUYEN - 7.035kW DC, 5.040kW AC, 8.291kW CEC AC RATING <br />APPLICABLE CODES <br />·ELECTRIC CODE:CEC 2022 <br />·FIRE CODE:CFC 2022 <br />·BUILDING CODE:CBC 2022 <br />·RESIDENTIAL CODE:CRC 2022 <br />SYSTEM SIZE: <br />MODULES: <br />INVERTER: <br />7035W DC, 5040W AC, 8291W CEC AC <br />RATING <br />SCOPE OF WORK <br />(21)SUNSPARK SST-335M3B-60 (335W) <br />(21)ENPHASE IQ8-60-2-US (240V)(SI-1) <br />BRANCH DETAILS: <br />1X11, 1X10 ENPHASE BRANCH <br />MAIN PANEL UPGRADE:REPLACE EXISTING MAIN <br />SERVICE PANEL WITH NEW 200/200 A MAIN BREAKER <br />SHEET CATALOG <br />SHEET REVISION DESCRIPTION <br />CS-01 B COVER SHEET <br />CS-02 B GENERAL NOTES <br />E-01 B SITE PLAN <br />S-01 B MOUNTING DETAILS <br />S-02 B STRUCTURAL DETAILS <br />E-02 B SINGLE LINE DIAGRAM <br />E-03 B ELECTRICAL CALCULATIONS <br />E-03.1 B EQUIPMENT ELEVATION VIEW <br />PL-01 B PLACARDS <br />SS B SPEC SHEET(S) <br />1. MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. <br />2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. <br />3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE <br />CONDITION MIGHT VARY. <br />4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH <br />CEC 110.26. <br />5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. <br />6. ALL CONDUCTORS SHALL BE 600V, 90°C STANDARD COPPER UNLESS OTHERWISE NOTED. <br />7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. <br />8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION <br />AND/OR THE UTILITY. <br />9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS <br />OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION <br />WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. <br />10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING <br />GENERAL NOTES <br />RISK CATEGORY- ll <br />BASIC WIND SPEED = 95 MPH @ 3-SEC GUST <br />GROUND SNOW LOAD = 0 PSF <br />DESIGN CRITERIA <br />PROJECT WINDSPEED DETERMINED USING THE <br />ASCE 7 STANDARD UNLESS DIRECTED OTHERWISE <br />BY LOCAL JURISDICTION AMENDMENTS <br />ROOF AREA CALCULATION <br />TOTAL ARRAY AREA = 373.05 sq.ft <br />TOTAL ROOF AREA = 3207 sq.ft <br />% ARRAY AREA IN ROOF = 11.63 % <br />The scope of the plans is for the installation of the solar photovoltaic system <br />only and the approval is subject to compliance with all applicable city and state <br />codes and regulations regarding construction. The approval of the plans does <br />not constitute any certification of the accuracy, completeness, or building permit <br />status of the existing buildings and structures as shown. <br />Bldg# 101115786 <br />Elec# 20180259 <br />Issued 07/28/23 <br />2009 W Adams St <br />08/01/23