Laserfiche WebLink
MSP <br />UM <br />LC <br />JB <br />65 <br />' <br />- <br />9 <br />" <br />99'-11" <br />65 <br />' <br />- <br />9 <br />" <br />99'-11" <br />23'-1" <br />5'-7" <br />16'-2" <br />1'-9" <br />JB <br />ARRAY LOCATIONS <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />34 MODULES - SYSTEM SIZE STC (13.6 KW DC / 11.05 KW AC) <br />2006 N WILLIAMS ST, SANTA ANA, CA 92705, USA (33.7622389, -117.8394606) <br />SYSTEM SUMMARY STC (13.6 kW DC / 11.05 kW AC) <br />STC DC: (34) 400W = 13.6 kW <br />STC AC: (34) 325W = 11.05 kW <br />● (34) SOLARIA POWER X-400R (400W) MODULES MODULES <br />● (34) IQ8M-72-2-US (240V) MICROINVERTERS <br />● 2x BRANCHES OF 9 CONCECTED IN PARALLEL <br />● 2x BRANCHES OF 8 CONCECTED IN PARALLEL <br />GOVERNING CODES <br />● 2022 CALIFORNIA FIRE CODE <br />● 2022 CALIFORNIA BUILDING CODE <br />● 2022 CALIFORNIA RESIDENTIAL CODE <br />● 2022 CALIFORNIA ELECTRICAL CODE <br />● 2022 CALIFORNIA ADMINISTRATIVE CODE <br />● 2022 CALIFORNIA ENERGY CODE <br />● 2022 CALIFORNIA EXISTING BUILDING CODE <br />● 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />● 2022 CALIFORNIA HISTORICAL BUILDING CODE <br />● 2022 CALIFORNIA MECHANICAL CODE <br />● 2022 CALIFORNIA PLUMBING CODE <br />● 2022 CALIFORNIA REFERENCED STANDARDS CODE <br />GENERAL NOTES <br />1) ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE <br />AND LUGS IN COMPLIANCE WITH UL REQUIREMENTS TO ACCOMMODATE <br />CONDUCTORS SHOWN. <br />2) THIS SYSTEM WILL NOT BE INTERCONCECTED UNTIL APPROVAL FROM THE <br />LOCAL JURISDICTION AND UTILITY IS OBTAINED. <br />3) ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE <br />THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE <br />WEATHERPROOF AND SHALL BE LISTED BY 'UL' FOR THE TYPE OF <br />APPLICATION AND 'UL' LABEL SHALL APPEAR ON ALL ELECTRICAL <br />EQUIPMENT. <br />4) WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN <br />CONCEALED SPACES (UNLESS APPROVED OTHERWISE) AND SCHEDULE-40 <br />PVC FOR BELOW GROUND INSTALLATIONS UNLESS NOTED OTHERWISE. <br />5) AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF <br />THE ARRAY SHALL BE SECURED IN PRIOR TO REQUESTING INSPECTION. <br />6) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL <br />GROUNDING ELECTRODE CONDUCTOR IF CECESSARY. <br />SAFETY PLAN NOTES <br />● INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME. <br />● INSTALLERS SHALL UPDATE NAME, ADDRESS AND PHONE NUMBER OF <br />NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE <br />STARTING WORK. <br />LOCATION OF NEAREST URGENT CARE FACILITY <br />(FOR INSTALLER USE ONLY) <br />● NAME: <br />● ADDRESS: <br />● PHONE NUMBER: <br />SITE PLAN & SAFETY PLAN <br />SCALE: 1/16" = 1'1 <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-1 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />CONTRACTOR <br />HO <br />P <br />E <br /> <br />S <br />C <br />H <br />R <br />O <br />E <br />D <br />E <br />R <br />20 <br />0 <br />6 <br /> <br />N <br /> <br />W <br />I <br />L <br />L <br />I <br />A <br />M <br />S <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />, <br /> <br />U <br />S <br />A <br />NAME: SUNERGY, INC. <br />ADDRESS: 23182 ALCALDE DR SUITE <br />GLAGUNA HILLS, CA 92653 <br />PHONE: (562) 544-7394 <br />LICENSE #: 1061794 <br />APN: - <br />EMAIL: - <br />PHONE: - <br />0001-12-2023 INITIAL <br />HOUSE PHOTO <br />SCALE: NTS <br />VICINITY MAP <br />SCALE: NTS <br />COVER PAGE <br />SHEET INDEX <br />PV-1 COVER PAGE <br />PV-2 ROOF PLAN WITH MODULES <br />PV-3 ATTACHMENT DETAIL <br />PV-4 THREE LINE DIAGRAM <br />PV-5 WIRING CALCULATION <br />PV-6 PLACARDS <br />PV-7+ EQUIPMENT SPECIFICATION <br />AHJ: CALIFORNIA | ORANGE | SANTA ANA <br />UTILITY: SOUTHERN CALIFORNIA EDISON <br />CO <br />PROJECT SITE <br />PROPERTY LINE <br />FENCE <br />GATEROOF ATTACHMENT <br />DIMENSIONSPV MODULE <br />OPTIMIZER <br />MICRO-INVERTER <br />LE <br />G <br />E <br />N <br />D <br />20 <br />0 <br />6 <br /> <br />N <br /> <br />W <br />I <br />L <br />L <br />I <br />A <br />M <br />S <br /> <br />S <br />T <br />FR <br />O <br />N <br />T <br /> <br />O <br />F <br /> <br />H <br />O <br />U <br />S <br />E <br />POOL <br />ROOF ACCESS <br />POINT <br />11 <br />AC <br />JB <br />MAIN SERVICE PANEL <br />(EXISTING, 200A) <br />UTILITY METER <br />(EXISTING) <br />AC DISCONCECT UNFUSED <br />(N/A) <br />ACF AC DISCONCECT FUSED <br />(N/A) <br />PRODUCTION METER <br />(N/A) <br />JUNCTION BOX <br />(NEW) <br />LOAD CENTER (COMBINER <br />PANEL) (NEW) <br />SOLAREDGE METER <br />(N/A) <br />SUBPANEL <br />(N/A) <br />DC DISCONCECT <br />(N/A) <br />DC COMBINER <br />(N/A) <br />EXISTING EQUIPMENT <br />AT <br />BACKUP LOAD PANEL <br />(N/A) <br />BATTERY <br />(N/A) <br />INV <br />SM <br />LC <br />BLP <br />SUB <br />DCC <br />DCD <br />EE <br />MSP <br />PM <br />UM <br />BAT <br />(34) INVERTER <br />(NEW) <br />AUTO TRANSFORMER <br />(N/A) <br />The scope of the plans is for the <br />installation of the solar photovoltaic <br />system only and the approval is <br />subject to compliance with all <br />applicable city and state codes and <br />regulations regarding construction. <br />The approval of the plans does not <br />constitute any certification of the <br />accuracy, completeness, or building <br />permit status of the existing buildings <br />and structures as shown. <br />Bldg# 101113734 <br />Elec# 20178629 <br />Issued 02/14/23 <br />2006 N Williams St <br />02/15/23