Laserfiche WebLink
SYSTEM SUMMARY STC (13.6 kW DC / 11.05 kW AC) <br />STC DC: (34) 400W = 13.6 kW <br />STC AC: (34) 325W = 11.05 kW <br />● (34) SOLARIA POWER X-400R (400W) MODULES MODULES <br />● (34) IQ8M-72-2-US (240V) MICROINVERTERS <br />● 2x BRANCHES OF 9 CONCECTED IN PARALLEL <br />● 2x BRANCHES OF 8 CONCECTED IN PARALLEL <br />AC wire details <br />WireID #Modules Nominal <br />Voltage <br />Backfeed *1.25 <br />/cond. set <br />Min <br />OCPD <br />Total <br />Power <br />Conductor <br />sets <br />ccConductors <br />/conduit <br />Expected <br />max temp <br />Adjusted ampacity (ampacity x temp <br />derate x conduit fill derate) <br />Conductor & <br />neutral size <br />EGC size <br />(Cu) <br />Conductor <br />metal <br />Max <br />length <br />V drop Min EMT <br />size <br />Min PVC <br />size <br />Min RMC <br />size <br />MS-01 9 240 V 15.19 A 20 A 2.9 kW 1 2 31 25 x 0.94 x - = 23.50 A 12 AWG (Q-Cable)06 AWG BARE <br />(NOT IN CONDUIT)Cu 50 ft 0.87 % - - - <br />MS-02 8 240 V 13.50 A 20 A 2.6 kW 1 2 31 25 x 0.94 x - = 23.50 A 12 AWG (Q-Cable)06 AWG BARE <br />(NOT IN CONDUIT)Cu 50 ft 0.77 %- - - <br />MCB-01 9 240 V 15.19 A 20 A 2.9 kW 1 2 31 35 x 0.94 x 1.00 = 32.90 A 10 AWG THWN-2 08 AWG THWN-2 Cu 50 ft 0.52 % 1/2 in 1/2 in 1/2 in <br />MCB-02 8 240 V 13.50 A 20 A 2.6 kW 1 2 31 35 x 0.94 x 1.00 = 32.90 A 10 AWG THWN-2 08 AWG THWN-2 Cu 50 ft 0.46 % 1/2 in 1/2 in 1/2 in <br />LC-01 34 240 V 57.38 A 60 A 11.0 kW 1 2 31 65 x 0.94 x 1.00 = 61.10 A 06 AWG THWN-2 08 AWG THWN-2 Cu 10 ft 0.16 % 3/4 in 3/4 in 3/4 in <br />UTILITY FEED + TOTAL BACKFEED <br />150A + 60A = 210A <br />LESS OR EQUAL TO <br />BUS RATING x 120% <br />200A x 120% = 240A <br />INTERCONCECTION 120% RULE <br />(MAIN PANEL) <br />CALCULATION ENSURES BUS IS <br />SAFE REGARDLESS OF LOADS <br />Isc(25°C) = 13.68A, Tisc = 0.048A/°C <br />Isc(T) = Isc(25°C) + [Tisc x (T-25°C)] <br />Isc(2°C) = 12.58A, Isc(31°C) = 13.97A <br />Voc(25°C) = 37.30V, Tvoc = -0.280V/°C <br />Voc(T) = Voc(25°C) + [Tvoc x (T-25°C)] <br />Voc(2°C) = 43.74V, Voc(31°C) = 35.62V <br />EXTREME CASE MODULE OUTPUT <br />(SOLARIA POWER X-400R (400W) MODULES) <br />ELECTRICAL NOTES <br />1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600V AND 90°C WET ENVIRONMENT. <br />3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. <br />5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL CECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. <br />6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CEC 690. <br />11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. <br />12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER CEC 310.15(B)(16). <br />13) IF ENVOY PRESENT, ENVOY BREAKER DETERMINED AT FACTORY BY MANUFACTURER. <br />14) IF ENVOY PRESENT, FOR IQ COMBINER USE SINGLE CT ON L1. AT SYSTEM CONTROLLER MAIN USE DOUBLE CT ON L1 AND L2. <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-5 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />CONTRACTOR <br />HO <br />P <br />E <br /> <br />S <br />C <br />H <br />R <br />O <br />E <br />D <br />E <br />R <br />20 <br />0 <br />6 <br /> <br />N <br /> <br />W <br />I <br />L <br />L <br />I <br />A <br />M <br />S <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />, <br /> <br />U <br />S <br />A <br />NAME: SUNERGY, INC. <br />ADDRESS: 23182 ALCALDE DR SUITE <br />GLAGUNA HILLS, CA 92653 <br />PHONE: (562) 544-7394 <br />LICENSE #: 1061794 <br />APN: - <br />EMAIL: - <br />PHONE: - <br />0001-12-2023 INITIAL <br />WIRING <br />CALCULATION <br />2006 N Williams St <br />02/15/23