Laserfiche WebLink
D INVMSP <br />JB <br />1 <br />2 <br />3'3' <br />18" MIN <br />18" MIN <br />3' <br />3' <br />2 X 4 RAFTER <br />@ 24" OC <br />2 78" <br />1-5/ <br />8 <br />" <br />MIN <br />PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />JIMENEZ <br />RESIDENCE <br />4.400 DC kW <br />4.048 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />1919 <br />N SPURGEON ST, <br />SANTA ANA, CA <br />92706 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP157692 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN04-20-23 REVISION <br />DESIGN BY: RD <br />CAD <br />F O R CA L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Ascend Energy <br />CRCR106 & Business and <br />Professions Code 5536.2 <br />MOUNTING PLAN <br />SOLAR PANEL DEAD WEIGHT CALCULATION <br />MODULE HYPERION <br />WIDTH (IN)LENGTH (IN)AREA (SQFT) WEIGHT (LBS) QTY <br />TOTAL <br />MODULE <br />AREA <br />TOTAL MODULE <br />WEIGHT <br />43.23 67.80 20.35 48.50 11 223.90 533.50 <br />RACKING EVEREST <br />RACKING <br />WEIGHT <br />LBS/LNFT <br />MOUNTING <br />SYSTEM WEIGHT <br />TOTAL SYSTEM <br />WEIGHT <br />TOTAL <br />ATTACHMENT <br />POINTS <br />POINT LOAD <br />CALCS DISTRIBUTED LOAD CALCULATION <br />.75 66.69 600.19 34 17.65 2.68 PSF <br />NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 <br />ROOF COVERAGE <br />TOTAL MODULE <br />AREA <br />ROOF FACE AREA <br />(SQFT) <br />ROOF <br />COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE <br />223.90 1348 16.61 % </= 33% 18" SET BACK AT RIDGE <br />ROOF INFORMATION <br />ROOF TYPE COMP SHINGLE ROOF - 2 LAYERS MAX <br />RAFTERS TRUSS RAFTER SPACING (IN)ATTACHMENT SPACING <br />2 X 4 N/A 24" OC 48" OC A2 <br />(N) 3/4" EMT CONDUIT <br />RUN ABOVE ROOF OR <br />UNDER EAVES WHERE POSSIBLE <br />7/8'' MINIMUM ABOVE THE ROOF <br />CEC 310.15(B)(3)(C) <br />(N) 34 TOTAL <br />ATTACHMENTS <br />@ 4FT ON CENTER <br />(N) 11 - MODEL#: HY-DH108P8-400 <br />400W HYPERION MODULES WITH <br />S440 SOLAREDGE OPTIMIZERS <br />STRING A - 11 MODULES <br />FIRE ACCESS POINT#2 <br />AREA NOT TO BE OVER <br />ANY DOORS, WINDOWS <br />OR OTHER <br />OBSTRUCTIONS. <br />FIRE ACCESS POINT#1 <br />AREA NOT TO BE OVER <br />ANY DOORS, WINDOWS <br />OR OTHER <br />OBSTRUCTIONS. <br />LEGEND <br />(E) EXISTING <br />(N) NEW <br />(P) PROPOSED <br />CONDUIT RUN <br />VIF VERIFY IN FIELD <br />JUNCTION BOX <br />MAIN SERVICE PANEL <br />AC COMBINER <br />INVERTER <br />AC DISCONNECT <br />SUBPANEL <br />SOLAR METER <br />FIRE ACCESS POINTS <br />FIRE PATHWAY/SETBACKS <br />JB <br />MSP <br />D <br />SP <br />INV <br />AC <br />M <br />x <br />MOUNTING PLAN <br />SCALE: 3/32"=1' <br />NOTE: ALL DIMENSIONS SHOWN <br />RELATING TO EXISTING <br />CONSTRUCTION ARE <br />APPROXIMATE. THE CONTRACTOR <br />SHALL FIELD VERIFY ALL ACTUAL <br />DIMENSIONS. DIMENSIONS, <br />UNLESS NOTED +/- IR VIF (VERIFY <br />IN FIELD), EXACT LOCATIONS, <br />DISTANCES, ELEVATIONS AND <br />SIMILAR DATA SHALL BE <br />GOVERNED BY ACTUAL FIELD <br />CONDITIONS. <br />A <br />(E) 200A MAIN SERVICE PANEL <br />SCE METER#: 222010-109642 <br />(N) SE3800H-US (240V) <br />SETAPP SOLAREDGE HD <br />INVERTER <br />(N) 30A AC DISCONNECT <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A A <br />3FT FIRE PATHWAY <br />3FT FIRE <br />PATHWAY <br />271° <br />AZIMUTH <br />20.0° <br />SLOPE <br />270° <br />AZIMUTH <br />30.0° <br />SLOPE <br />90° <br />AZIMUTH <br />30.0° <br />SLOPE <br />MODULE <br />EVEREST <br />CROSSRAIL 44-X <br />EVEREST SPLICE <br />FOOT X <br />END CLAMP <br />ASSEMBLY <br />EVEREST K2 SOLAR SEAL <br />BUTYL PAD <br />2 - MSX60 SELF-DRILLING <br />WOOD SCREWS THROUGH <br />7/16" OSB DIRECTL INTO THE <br />RAFTER FULLY THREADED, <br />1-5/8" OF EMBEDMENT INTO <br />RAFTER <br />ROOF ATTACHMENT DETAIL <br />COMP SHINGLE ROOF <br />SCALE: 2" = 1'-0" <br />SIDE VIEW <br />NOTE: <br />MODULES WILL BE INSTALLED FLUSHED TO <br />EXISTING ROOF SLOPE <br />STRUCTURAL ONLY <br />www.vincise.com <br />S T R U C T U R A L E N G I N E E R S <br />4.28.2023 <br />1919 N Spurgeon <br />St06/15/23