My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1919 N Spurgeon St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Spurgeon St
>
1919 N Spurgeon St
>
1919 N Spurgeon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:00:35 PM
Creation date
6/1/2025 12:00:17 PM
Metadata
Fields
Template:
Plan
Permit Number
20179904
101115455
101115782
Full Address
1919 N Spurgeon St
Document Relationships
101115455 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spurgeon St\1919 N Spurgeon St
101115782 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spurgeon St\1919 N Spurgeon St
20179904 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spurgeon St\1919 N Spurgeon St
Text box
ID:
1
Creator:
Import Agent
Created:
6/1/2025 12:00 PM
Modified:
5/30/2025 2:05 PM
Text:
WWW.TITANSOLARPOWER.COM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ELECTRICAL <br />CALCULATIONS <br />PROJECT NAME <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />JIMENEZ <br />RESIDENCE <br />4.400 DC kW <br />4.048 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />1919 <br />N SPURGEON ST, <br />SANTA ANA, CA <br />92706 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 85210 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP157692 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN04-20-23 REVISION <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Ascend Energy <br />CRCR106 & Business and <br />Professions Code 5536.2 <br />E2 <br />MODULE SPECIFICATION INVERTER SPECIFICATION LOCATION INFORMATION <br />MANUFACTURER HYPERION INVERTER MAKE SOLAREDGE NEC TABLE 310.15 (B)(2)(a)-TEMP CORRECTION FACTORS <br />MODEL NO.HY-DH108P8-400 INVERTER MODEL NO.SE3800H-US (240V)HIGH TEMP 39 <br />PEAK POWER 400 WATTS MAX INPUT VOLTAGE 480 VOLTS LOW TEMP -7 <br />MPP VOLTAGE (VMPP)31.01 VOLTS MAX INPUT CURRENT 10.5 AMPS VOLTAGE CORRECTION FACTOR 1.12 <br />MPP CURRENT (IMPP)12.90 AMPS NOMIMAL AC VOLTAGE 240 VOLTS ROOF TEMP + 33°-IF RACEWAY CONDUIT IS LESS THAN 7/8" ABOVE ROOF 72 <br />OPEN CIRCUIT VOLTAGE (VOC)37.07 VOLTS MAX AC CURRENT 16 AMPS TEMP CORRECTION FACTOR (EXPOSED)0.50 <br />SHORT CIRCUIT CURRENT (ISC)13.79 AMPS TEMP CORRECTION FACTOR (INSIDE CONDUIT)0.91 <br />OPTIMIZER SPECIFICATION <br />MAKE SOLAREDGE <br />MODEL NUMBER S440 <br />MAXIMUM INPUT DC POWER 440 WATTS <br />ABSOLUTE MAX INPUT VOLTAGE (VOC)60 VDC <br />MAX SHORT CIRCUIT CURRENT (ISC)14.50 ADC <br />MAX OUTPUT CURRENT 15 ADC <br />MAX OUTPUT VOLTAGE 60 VDC <br />DC CONDUCTOR AMPACITY CALCULATIONS <br />ARRAY STRING TO JBOX TO INVERTER <br />AC CONDUCTOR AMPACITY CALCULATIONS <br />BETWEEN INVERTER TO POINT OF CONNECTION AND/OR MAIN SERVICE PANEL <br />EXPECTED WIRE TEMPERATURE (FREE AIR)39 CELSIUS AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 39 CELSIUS <br />ADD 33°C FOR CONDUITS EXPOSED TO SUNLIGHT <br />ON OR ABOVE ROOF 72 CELSIUS TEMPERATURE CORRECTION FACTOR 0.91 <br />TEMPERATURE CORRECTION FACTOR <br />CEC TABLE 310.15 (B)(2)(A)0.91 # OF CURRENT CARRYING CONDUCTORS 2 <br /># OF CURRENT CARRYING CONDUCTORS 2 CONDUIT FILL CORRECTION 1.00 1.00 (3 WIRES) .80 (4-6 WIRES) <br />.70 (7-9 WIRES) .50 (10-20 WIRES) <br />CONDUIT FILL CORRECTION 1.00 1.00 (3 WIRES) .80 (4-6 WIRES) <br />.70 (7-9 WIRES) .50 (10-20 WIRES)CIRCUIT CONDUCTOR SIZE #10 AWG <br />CIRCUIT CONDUCTOR SIZE #10 AWG CIRCUIT CONDUCTOR AMPACITY @ 90°40 AMPS <br />CIRCUIT CONDUCTOR AMPACITY@75°35 AMPS INVERTER'S MAXIMUM AC OUPUT CURRENT 16 AMPS <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY 18.75 AMPS (P401 ISC X 1.25) REQUIRED AC CONDUCTOR AMPACITY 20.00 AMPS <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR 31.85 AMPS DERATED AMPACITY OF CIRCUIT CONDUCTORS 36.40 AMPS <br />NOTE: DERATED AMPACITY OF CIRCUIT CONDUCTOR MUST BE <br />LARGER THAN REQUIRED CIRCUIT CONDUCTOR AMPACITY 31.85 >/= 18.75 NOTE: DERATED AMPACITY OF CIRCUIT CONDUCTOR MUST BE LARGER THAN <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY 36.40 >/= 20.00 <br />1919 N Spurgeon <br />St06/15/23
The URL can be used to link to this page
Your browser does not support the video tag.