Laserfiche WebLink
4 4 <br />(E)200A CENTER FED <br />MAIN PANEL <br />UTILITY <br />GRID <br />(E <br />) <br />2 <br />0 <br />0 <br />A <br /> <br />M <br />A <br />I <br />N <br />BR <br />E <br />A <br />K <br />E <br />R <br />EXISTING 120/240V 1PH 60HZ <br />METER#:SOUTHERN CALIFORNIA <br />EDISON <br />SCE-222013-489241M <br />(N)125A SUB <br />PANEL <br />(N)35A PV BREAKER <br />AT OPPOSITE END <br />OF THE BUS BAR <br />RELOCATED LOADS <br />(N)60A AC <br />DISCONNECT <br />EATON DG222URB <br />PV SYSTEM AC <br />DISCONNECT SWITCH <br />NON FUSED VISIBLE OPEN <br />60A, 120/240V 2P <br />4 15A <br />20A <br />20A <br />AC COMBINER WITH <br />ENPHASE ENVOY <br />X-IQ-AM1-240-4 <br />120/240 NEMA 3R <br />INSTALL (2)20A PV <br />2P BREAKERS <br />(N)ENPHASE IQ <br />COMBINER 4 <br />(ONLY FOR SOLAR, <br />NO LOADS TO BE <br />ADDED) <br />(10)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W,MODULES WITH <br />(10)ENPHASE IQ8PLUS-72-2-US(240V)(SI-1) <br />(1) BRANCH OF (10) MICRO-INVERTERS <br />(N)JUNCTION <br />BOX <br />2A 1A <br />DC CONDUCTORS <br />AC CONDUCTORS <br />(12)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W,MODULES WITH <br />(12)ENPHASE IQ8PLUS-72-2-US(240V)(SI-1) <br />(1) BRANCH OF (12) MICRO-INVERTERS <br />(N)JUNCTION <br />BOX <br />2 1 <br />DC CONDUCTORS <br />AC CONDUCTORS <br />(N)EV CHARGER <br />5 <br />(N)60A 2P <br /> BREAKER 3 <br />(N)60A SUB FEEDER <br />BREAKER AT OPPOSITE <br />END OF THE BUS BAR <br />SINGLE LINE DIAGRAM <br />E-01 <br />ELECTRICAL NOTES <br />1.CONDUCTORS EXPOSED TO SUNLIGHT <br />SHALL BE LISTED AS SUNLIGHT <br />RESISTANT PER CEC 310.10(D). <br />2.CONDUCTORS EXPOSED TO WET <br />LOCATIONS SHALL BE SUITABLE FOR USE <br />IN WET LOCATIONS PER CEC 310.10(C). <br />3.MAXIMUM DC/AC VOLTAGE DROP SHALL <br />BE NO MORE THAN 2%. <br />4.ALL CONDUCTORS SHALL BE IN CONDUIT <br />UNLESS OTHERWISE NOTED. <br />5.BREAKER/FUSE SIZES CONFORMS TO <br />CEC 240. <br />6.AC EQUIPMENT GROUNDING <br />CONDUCTOR SIZED PER CEC 250.122. <br />7.AMBIENT TEMPERATURE CORRECTION <br />FACTOR IS BASED ON CEC 690.31(A). <br />8.AMBIENT TEMPERATURE ADJUSTMENT <br />FACTOR IS BASED ON CEC 310.15(B)(2). <br />9.MAX. SYSTEM VOLTAGE CORRECTION IS <br />PER CEC 690.7. <br />10.CONDUCTORS ARE SIZED PER CEC <br />TABLE CEC 310.15(B)(16). <br />SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 8800W, AC SYSTEM SIZE - 6380W, CEC AC RATING - 7928W <br />33.762753, -117.872883 <br />APN: 002-10-305 <br />CUSTOMER INFORMATION <br />NAME:BEATRICE RAYA <br />DATE:7/21/2022 <br />SCALE:AS NOTED REV:D <br />AHJ:CA-CITY OF SANTA ANA <br />UTILITY:SOUTHERN CALIFORNIA EDISON <br />PRN NUMBER:TPS-56928 <br />DRAFTED BY: <br />P.SANKET <br />QC'ED BY: <br /> A.N.KRISHNAN <br />PAPER SIZE:17"X11" <br />ADDRESS:2004 N ROSS ST, SANTA ANA, <br />CA 92706 <br />ADDRESS: 525W, BASELINE RD <br />MESA AZ,85210 <br />LICENSE#'S CA:1062072 BL:010238 <br />TSP NUMBER:TSP133481 <br />CONDUIT SCHEDULE <br />TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND <br />1,1A NONE (2) 12AWG ENPHASE Q CABLE <br />PER BRANCH CIRCUIT NONE (1) 6AWG BARE COPPER <br />2,2A,3 <br />1-1/4" SCH 40 PVC (BELOW <br />GROUND) 3/4" SCH 80 PVC <br />(ABOVE GROUND) <br />(2) 10AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 <br />4 3/4"EMT (2) 8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 <br />5 3/4"EMT (2) 6 AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 <br />NOTE: <br />SUB PANEL RATING:125A, SUB FEEDER BREAKER RATING:60A <br />120% RULE: (125AX1.2)-60A=90A =>ALLOWABLE BACKFEED IS 90A <br />OCPD CALCULATIONS: <br />INVERTER OVERCURRENT PROTECTION= <br />INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS <br />=1.21x1.25x22=33.28 A =>PV BREAKER = 35A <br />ALLOWABLE BACKFEED 90A =>35A PV BREAKER <br />THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS. <br />2004 N Ross St <br />12/14/22