My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2036 S Main St - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2036 S Main St
>
2036 S Main St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:00:35 PM
Creation date
6/1/2025 12:00:27 PM
Metadata
Fields
Template:
Plan
Permit Number
20178080
101112939
Full Address
2036 S Main St
Document Relationships
101112939 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Main St\2036 S Main St
20178080 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Main St\2036 S Main St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MSPACD INV <br />(UNLESS BUSBAR IS FULLY RATED) (CEC 705.12) <br />WHITE LETTERS WITH RED BACKGROUND <br />M <br />IN <br />V <br />E <br />R <br />T <br />E <br />R <br />CEC 690.35(F) <br />ARRAY <br />DCJ/B <br />CEC 690.31(G)(3)(4) & CEC 690.13(G)(4) <br />TO BE PLACED AT LEAST EVERY 10FT <br />WHITE LETTERS WITH RED BACKGROUND <br />CEC 690.35(F) <br />CEC 690.53 <br />WHITE LETTERS WITH RED BACKGROUND <br />CEC 690.56 (C)(3) <br />WHITE LETTERS WITH RED BACKGROUND <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />SYSTEM <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />ELECTRIC SHOCK HAZARD <br />IF A GROUND FAULT IS INDICATED <br />NORMALLY GROUNDED CONDUCTORS <br />MAY BE UNGROUNDED AND ENERGIZED <br />WARNING! <br />WARNING - Electric Shock Hazard <br />No user serviceable parts inside <br />Contact authorized service provider for assistance <br />WARNING! <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE UNGROUNDED <br />AND MAY BE ENERGIZED <br />WARNING <br />INVERTER OUTPUT CONNECTION DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />MAXIMUM VOLTAGE . <br />MAXIMUM CIRCUIT CURRENT <br />. <br />MAX RATED OUTPUT CURRENT <br />OF THE CHARGE CONTROLLER <br />OR DC-TO-DC CONVERTER <br />(IF INSTALLED) . <br />A <br />V <br />A <br />10.50 <br />15 <br />480 <br />INVERTER 1 <br />CEC 690.13.G.3 & CEC 690.13.G.4 <br />WHITE LETTERS WITH RED BACKGROUND <br />CEC 690.15, 690.13(B) <br />BLACK TEXT WITH YELLOW BACKGROUND <br />SOLAR DISCONNECT <br />CEC 690.13(B) <br />WHITE LETTERS WITH RED BACKGROUND <br />BLACK OUTLINE WITH BLACK TEXT / WARNING IS IN <br />BLACK TEXT AND ORANGE BACKGROUND <br />BLACK OUTLINE WITH BLACK TEXT / WARNING IS IN <br />BLACK TEXT AND ORANGE BACKGROUND <br />CAUTION: SOLAR ELECTRIC <br />SYSTEM CONNECTED <br />CEC 690.54 <br />WHITE LETTERS WITH RED BACKGROUND <br />CEC 690.17(E) <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />! <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED AC OPERATING CURRENT 16.00 AMPS <br />AC NOMINAL OPERATING VOLTAGE 240 VOLTS <br />CEC 690.13(B) <br />WHITE LETTERS WITH RED BACKGROUND <br />BLACK OUTLINE WITH BLACK TEXT / WARNING IS IN <br />BLACK TEXT AND ORANGE BACKGROUND <br />SOLAR DISCONNECT <br />CEC 690.56(C)(1)(A) <br /> BLACK OUTLINE WITH <br />BLACK TEXT AND <br />WHITE BACKGROUND / <br />NOTE ON TOP IS IN <br />BLACK TEXT AND <br />YELLOW BACKGROUND <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN PV <br />SYSTEM AND REDUCE <br />SHOCK HAZARD IN ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />! <br />A <br />C <br />71 <br />0 <br />0 <br /> <br />W <br /> <br />F <br />l <br />o <br />r <br />i <br />d <br />a <br /> <br />A <br />v <br />e <br />n <br />u <br />e <br />He <br />m <br />e <br />t <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />5 <br />4 <br />5 <br />CU <br />R <br />R <br />E <br />N <br />T <br /> <br />H <br />O <br />M <br />E <br />CS <br />L <br />B <br />- <br />C <br />4 <br />6 <br />, <br /> <br />C <br />- <br />1 <br />0 <br />, <br /> <br />B <br /> <br /># <br /> <br />1 <br />0 <br />4 <br />5 <br />0 <br />1 <br />6 <br />MC <br />P <br />H <br />E <br />R <br />S <br />O <br />N <br /> <br />E <br />N <br />G <br />I <br />N <br />E <br />E <br />R <br />I <br />N <br />G <br />Ju <br />r <br />u <br />p <br />a <br /> <br />V <br />a <br />l <br />l <br />e <br />y <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />5 <br />0 <br />9 <br />(9 <br />0 <br />9 <br />) <br /> <br />5 <br />6 <br />6 <br />- <br />0 <br />0 <br />6 <br />6 <br />so <br />l <br />a <br />r <br />@ <br />m <br />c <br />p <br />e <br />. <br />g <br />r <br />o <br />u <br />p <br />De <br />s <br />i <br />g <br />n <br />e <br />d <br /> <br />b <br />y <br />92 <br />4 <br />0 <br /> <br />L <br />i <br />m <br />o <br />n <br />i <br />t <br />e <br /> <br />A <br />v <br />e <br />CH <br />R <br />I <br />S <br /> <br />R <br />O <br />M <br />A <br />N <br />DA <br />T <br />E <br />: <br /> <br />10 <br />/ <br />1 <br />4 <br />/ <br />2 <br />0 <br />2 <br />2 <br /> <br /> <br /> <br /> <br />PL <br />O <br />T <br />T <br />E <br />D <br />: <br /> <br />10 <br />/ <br />1 <br />4 <br />/ <br />2 <br />0 <br />2 <br />2 <br />DE <br />S <br />I <br />G <br />N <br />E <br />R <br />: <br /> <br /> V <br />. <br />V <br />. <br /> <br /> A <br />H <br />J <br />: <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />4. <br />3 <br />8 <br />0 <br /> k <br />W <br />p <br />D <br />C <br /> <br />/ <br /> <br />4. <br />0 <br />2 <br />4 <br /> k <br />W <br />p <br />A <br />C <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />P <br />L <br />A <br />N <br />SC <br />O <br />T <br />T <br /> <br />T <br />E <br />D <br />R <br />O <br />20 <br />3 <br />6 <br /> <br />M <br />A <br />I <br />N <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />N/ <br />A <br />AP <br />N <br />: <br /> <br />1 <br />5 <br />0 <br />7 <br />4 <br />1 <br />7 <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN. <br />DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES <br />"WARNING" <br /> PHOTOVOLTAIC ARRAY <br />DISCONNECTION OF NEUTRAL OR GROUNDED CONDUCTORS MAY RESULT IN <br />OVERVOLTAGE ON ARRAY OR INVERTER. <br />6x8" TYP. - CEC 705.10 <br />NOTES <br />1. CEC ARTICLES 690 AND 705 AND CRC SECTION R331 MARKINGS SHOWN HEREON <br />2. ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: <br />A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR <br />ELECTRO-PLATING <br />B. RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK <br />C. ARIAL FONT <br />3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. <br />4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING POP-RIVETS OR SCREWS. <br />5. THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. <br />6. WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND <br />MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [CEC 110.21(B) FIELD MARKING]. <br />7. ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE <br />WEATHER RESISTANT [IFC 605.11.1.3] <br />SIGNAGE <br />PV52036 MAIN ST SANTA ANA, CA 92707 <br />YOU ARE <br />HERE <br />SERVICE <br />PANEL <br />AC DISCONNECT FOR <br />UTILITY OPERATIONS <br />(RAPID SHUTDOWN <br />DEVICE) <br />INVERTER <br />SOLAR MODULES <br />(RAPID SHUTDOWN) <br />2036 S Main St <br />12/06/22
The URL can be used to link to this page
Your browser does not support the video tag.