Laserfiche WebLink
PV SYSTEM <br />AS INDICATED <br />Project Name Project Address Project Description <br />SHEET SIZE <br />11'' X 17'' ANSI B <br />SHEET NUMBER <br />General Notes <br />Date <br />Scale <br />Project <br />MAY 19, 2023 <br />Paul Czajka 2030 W Summer Wind, <br />Santa Ana, CA 92704 T <br />GENERAL NOTES:APPLICABLE CODES <br />SHEET INDEX <br />TITLE PAGE <br />LINE DIAGRAM <br />CODE REQUIRED SIGNAGE <br />ATTACHMENT LAYOUT <br />MODULE DATA SHEET <br />SITE PLAN <br />PROJECT VICINITY MAP PROJECT SATELLITE VIEW <br />T <br />PV1 <br />PV2 <br />PV3 <br />PV4 <br />D1 <br />D2 <br />D3 <br />D4 <br />D5 <br />D6 <br />D7 <br />INVERTER DATA SHEET <br />ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED AND LICENSED <br />ELECTRICAL CONTRACTOR. <br />ALL SOLAR MODULES SHALL BE UL LISTED 1703 & CEC APPROVED. ALL <br />INVERTERS SHALL BE UL LISTED 1741 CERTIFIED & CEC APPROVED. ALL <br />ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED FOR IT'S <br />PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR <br />EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. <br />THE ELECTRICAL CONTRACTOR IS ADVISED THAT ALL DRAWINGS AND <br />COMPONENT MANUALS ARE TO BE UNDERSTOOD PRIOR TO INSTALLATION. <br />THE CONTRACTOR IS ADVISED TO HAVE ALL SWITCHES IN THE OFF POSITION <br />AND FUSES REMOVED PRIOR TO INSTALLATION OF FUSE-BEARING <br />COMPONENTS. <br />THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY <br />SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL <br />1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PV SYSTEM <br />WHEN THE UTILITY GRID IS NOT OPERATIONAL. <br />PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL <br />INSPECTIONS AND APPROVALS ARE OBTAINED FROM THE LOCAL AUTHORITY <br />HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. <br />THE METHOD OF ATTACHMENT CREATES A UNIFIED STRUCTURE TO MEET <br />DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. SOLAR MODULES <br />WILL BE SECURED TO THE EXISTING ROOF AS SPECIFIED ON THE <br />STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED <br />BY THE PV SYSTEM. ALL STRUCTURAL DESIGN AND INSTALLATION <br />COMPONENTS ARE THE RESPONSIBILITY OF OTHERS AND OUTSIDE THE <br />SCOPE OF THIS DOCUMENT. <br />ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR SITE <br />CONDITIONS. CONNECTORS SHALL BE TORQUED PER DEVICE LISTING OR <br />ENGINEERING RECOMMENDATIONS. <br />ALL ROOFING REPAIR MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF <br />AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOF IN <br />MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />PROJECT DESCRIPTION: <br />SYSTEM SIZE: DC STC: ____ kW <br /> AC SIZE: ____ kW <br />SOLAR MODULES: (___) <br />INVERTER: (___) <br /> <br />MOUNTING SYSTEM: <br />EXISTING MSP BUS: ____ <br />EXISTING MAIN BREAKER: ____ <br />NEW PV BREAKER: ____ <br />RACKING DATA SHEET <br />GROUNDING SPECS <br />RACKING DETAILSD8 <br />PROPERTY DETAILS: <br />TWO STORY BUILDING BUILDING <br />OCCUPANCY GROUPS (R-3) <br />TYPE OF CONSTRUCTION (V-B) <br />AUTOMATIC FIRE SPRINKLERS (NO) <br />ROOF TYPE: <br />ROOF STRUCTURE: <br />PARCEL NUMBER: 41222216 <br />LOT AREA: 3,078 SQFT <br />LIVING AREA: 1,379 SQFT <br />SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL <br />BE PROVIDED FOR THE DWELLING PER CRC R314 AND R315 <br />Drawn By: Unique Solar Design <br />California Solar Group <br />CSLB # 1067781 <br />C-10 <br />Contractor Note <br />7647 Hayvenhurst Ave., Unit 26 <br />Van Nuys, CA 91406 <br />casolargroup.com <br />info@casolargroup.com <br />Phone Number: +1 818 658 2362 <br />Address & Phone Number Signature Company Logo <br />16 <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA GREEN BUILDING <br />STANDARDS CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />125A <br />125A <br />30A <br />6.56 <br />6.11 <br />RAFTERS 2'' x 6'' @ 24'' O.C <br />FLAT CONCRETE TILE <br />ENPHASE IQ8A MICROINVERTER (IQ8A-72-2-US (120/240V) [240] [SI1]) <br />IRONRIDGE XR10 RACKING <br />RACKING CERTIFICATIONS <br />16 <br />6.56KW DC Roof Mounted <br />PV Electrical System <br />16-Silfab 410W PV Modules <br />16-IQ8A Enphase Microinverters <br />ENPHASE COMBINER DATA SHEET <br />Silfab 410W Modules (SIL-410BG) <br />ATTACHMENT DATA SHEET <br />N <br />The scope of the plans is for the installation <br />of the solar photovoltaic system only and the <br />approval is subject to compliance with all <br />applicable city and state codes and <br />regulations regarding construction. The <br />approval of the plans does not constitute any <br />certification of the accuracy, completeness, <br />or building permit status of the existing <br />buildings and structures as shown. <br />REVISED <br />101114405/20179136 <br />Issued 03/24/23 <br />20179807 <br />Issued 06/06/23 <br />2030 W Summer <br />Wind06/06/23