Laserfiche WebLink
1235674 <br />A <br />B1 <br />B <br />E <br />D <br />C <br />3A <br />EGRESS STAIRCASE 2 <br />EGRESS STAIRCASE 1 <br />9'-0" CLG. <br />8'-0" CLG. <br />TRASH ENCLOSURE <br />CD <br />S <br />12'-8" CLG. <br />(N)2x4 LED LIGHT FIXTURE <br />(N) 6" LED RECESSED DOWNLIGHTS <br />(N) SUPPLY DIFFUSER <br />(N) RETURN AIR <br />(N) EXHAUST FAN <br />(N) EXHUAST VENT <br />WALL MOUNT LIGHT FIXT. (OUTDOOR LIGHTING). ALL LUMINARIES <br />MOUNTED TO BE BUILDING SHALL BE HEIGHT EFFICACY AND MUST BE <br />CONTROLLED BY A MOTION SENSOR WITH INTEGRAL PHOTO CONTROL <br />EXIT SIGN, REFER TO 1/AD1 <br />SMOKE DETECTOR, ALARMS SHALL BE RECEIVE THEIR PRIMARY POWER <br />FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY <br />BACKUP. (907.2.11.4 CBC, R314.6 CRC) INTERCONNECTED <br />CARBON MONOXIDE DECTECTOR - SHALL BE INTERCONNECTED HARD- <br />WIRED WITH BATTERY BACKUP. <br />2'x2' CEILING GRID AND ACOUSTICAL TILE. REFER TO DETAIL 9/AD2 <br />S <br />CD <br />JOB# <br />DATE <br />DRAWN <br />SCALE <br />Th <br />i <br />s <br /> <br />D <br />u <br />c <br />o <br />u <br />m <br />e <br />n <br />t <br /> <br />i <br />s <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />Y <br />N <br /> <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C. <br />, <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />be <br /> <br />r <br />e <br />p <br />o <br />r <br />d <br />u <br />c <br />e <br />d <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />c <br />o <br />n <br />s <br />e <br />n <br />t <br /> <br />o <br />f <br /> <br />Y <br />N <br />G <br /> <br />A <br />R <br />CH <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C <br />. <br />© <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />No. C-32798 <br />HC <br />F <br />RADSEN <br />E <br />S <br />TAT <br />LCAIOF <br />E <br />ILC <br />A <br />ORNI <br />TC <br />ITEYENNY NG <br />DATE <br />RENEWAL <br />03-31-25 <br />1/4" = 1'-0" <br />A2.5 <br />FI <br />R <br />S <br />T <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />R <br />E <br />F <br />L <br />E <br />C <br />T <br />E <br />D <br />CE <br />I <br />L <br />I <br />N <br />G <br /> <br />P <br />L <br />A <br />N <br />YC23005 <br />AN <br />C <br />E <br />N <br />A <br />Y <br /> <br />C <br />O <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />JAN 2024 <br />T.N. <br />21 <br />0 <br /> <br />W <br />. <br /> <br />1 <br />9 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />FIRST FLOOR REFLECTED CEILING PLAN 1SCALE: <br />1/4" = 1'-0" <br />ELECTRICAL LEGENDSELECTRICAL NOTES <br />1. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL <br />AND ELECTRICAL OR MECHANICAL DRAWINGS. OBTAIN CLARIFICATION <br />FROM ARCHITECT IN WRITING BEFORE PROCEEDING WITH THE WORK IN <br />QUESTION OR RELATED WORK. <br />2. WHEN CEILING INTERRUPTIONS OCCUR, SUCH AS PARTITIONS, FURR <br />DOWNS ETC., CONTRACTOR SHALL CHECK AND VERIFY THAT WORK IS <br />BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. <br />SHOULD THERE BE ANY QUESTIONS, CONTRACTOR IS RESPONSIBLE FOR <br />OBTAINING A CLARIFICATION FROM THE ARCHITECT IN WRITING BEFORE <br />PROCEEDING WITH THE WORK IN QUESTION OR RELATED WORK. <br />3. ALL NEW CEILING FIXTURES, SWITCHES, AND MOTION SENSORS SHALL <br />MATCH BUILDING STANDARD U.N.O. <br />4. LOCATE ALL LIGHT FIXTURES, SPEAKERS, ACCESS PANELS, LIFE-SAFETY <br />FIXTURES, ETC., IN STRAIGHT LINES AND IN CENTER OF CEILING TILES <br />U.N.O. <br />5. THERE SHALL BE NO COMBUSTIBLE MATERIALS IN THE PLENUM SPACE <br />INCLUDING ALUMINUM FLEX, ALUMINUM CONDUITS, AND POT METAL LINE <br />OF FINISH CEILING. <br />6. ALL NEW CONDUITS BOXES, DUCTS, HVAC UNITS, PIPES, ETC. SHALL BE <br />INSTALLED AS HIGH AS POSSIBLE, NOT LOWER THAN 8" ABOVE LINE OF <br />FINISH CEILING. <br />7. WHEN FIXTURES INTERRUPT MAIN RUNNERS, CUT AND REINFORCE AS <br />REQUIRED. <br />8. ALL FLUORESCENT FIXTURE LAMPS SHALL BE IDENTICAL FROM ONE <br />MANUFACTURER. <br />9. PROVIDE EMERGENCY LIGHTING LEVELS AS REQUIRED BY CODE. <br />10. THE CONTRACTOR SHALL PROVIDE RECORD DOCUMENTS OF ALL WORK <br />PREFORMED AND SHALL INDICATE ANY DEVIATIONS FROM THE DESIGN <br />DOCUMENTS AS WELL AS THE LOCATION OF ALL WORK WHICH IS HIDDEN <br />BY SUBSEQUENT CONSTRUCTION. THE RECORD DOCUMENTS SHALL BE <br />GIVEN TO THE OWNER AT COMPLETION OF TENANT CONSTRUCTION <br />PRIOR TO APPLICATION FOR FINAL PAYMENT. <br />Da <br />t <br />e <br /> <br />D <br />e <br />s <br />c <br />r <br />i <br />p <br />t <br />i <br />o <br />n <br />11. TACTILE EXIT SIGNS SHALL BE REQUIRED AT THE FOLLOWING LOCATIONS: <br />- EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A <br />TACTILE EXIT WITH THE WORD “EXIT.” <br />- EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A <br />CORRIDOR OR HALLWAY, WHICH IS REQUIRED TO HAVE A VISUAL EXIT <br />SIGN, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS <br />“EXIT ROUTE.” <br />- EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY <br />A SIGN WITH THE WORDS “TO EXIT.” <br />210 W 19th St <br />4/14/2025