Laserfiche WebLink
FIG. (B)FIG. (A) <br />PROPORTIONS <br />SYMBOL <br />MEN <br />11B-703.7.2.2 <br />ISA OF TTY <br />INTERNATIONAL SYMBOL <br />INTERNATIONAL SIGN <br />FOR HEARING LOSS <br />INTERNATIONAL ACCESSIBILITY <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />R <br />E <br />F <br />L <br />E <br />C <br />T <br />I <br />V <br />E <br /> <br />S <br />U <br />R <br />F <br />A <br />C <br />E <br />6" MAX. <br />ELEVATIONSB <br />NOTE: <br />54" PREFERRED <br />DOOR WIDTH PLUS <br />1. <br />DOOR TYPE: <br />3. <br />2. <br />HARDWARE: <br />EITHER ATTACHED PANEL OR BOTTOM RAIL. <br />KNOWLEDGE OR EFFORT. <br />4. <br />5. <br />REQUIRING GRASPING). <br />MOUNTED 34" TO 44". <br />5 LBS. FOR INTERIOR. <br />MINIMUM 10" HIGH SMOOTH SURFACE AT DOOR BOTTOM, <br />OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL <br />OPENABLE BY SINGLE EFFORT LEVER-TYPE DEVICE (NOT <br />MAXIMUM 5 LBS. EFFORT TO OPERATE EXTERIOR DOOR, <br />HANDLE <br />KICK PLATE <br />34" TO 44" HIGH LEVER <br />10" MIN. BOTTOM <br />RAIL OR PROVIDE <br />RUBBER BUMPER ON CHAIR <br />OR WALL OCCURS <br />12" MINIMUM IF DOOR HAS <br />WHERE ADJACENT OBSTRUCTION <br />BOTH A CLOSER AND A LATCH <br />REQUIRED CLEAR SPACE <br />48" MINIMUM <br />REQUIRED CLEAR SPACE <br />24" MIN. EXTERIOR <br />18" MIN. INTERIOR <br />B CORRIDOR PLAN <br />18" MIN. <br />INTERIOR <br />EXTERIOR <br />24" MIN. <br />OF BLDG. <br />PLANA <br />SWINGS. <br />24" MIN. EXTERIOR & <br />18" MINIMUM INTERIOR <br />BEYOND STRIKE EDGE OF A <br />GATE OR DOOR ON THE <br />SIDE TOWARD WHICH IT <br />18" MIN. INTERIOR <br />24" MIN. EXTERIOR <br />A HIGH FORWARD REACH LIMIT <br />1. <br />3. <br />2. <br />NOTES: <br />B <br />X SHALL BE < 25 INCHES; Z SHALL BE > X. <br />WHEN X < 20 INCHES, THEN Y SHALL BE 48 INCHES MAXIMUM. <br />WHEN X IS 20 TO 25 INCHES, THEN Y SHALL BE 44 INCHES MAXIMUM. <br />MAXIMUM FORWARD REACH OVER AN OBSTRUCTION <br />C VESTIBULE PLANB <br />RAMP LANDING AT <br />DOORWAY PLAN <br />NOTES: <br />1. CLEAR SPACES MUST BE LEVEL TO PREVENT WHEELCHAIRS FROM ROLLING WHEN THE OCCUPANT <br />RELEASES THE WHEEL GRIPS TO REACH FOR THE DOOR. 1/4" PER FOOT IS ALLOWED FOR DRAINAGE. <br />2. WHERE DOORS OPEN ONTO, BUT NOT INTO A CORRIDOR, THE REQUIRED LEVEL AREA BEYOND THE <br />DOORS MAY BE A MINIMUM OF 48". FOR ADDITIONAL INFORMATION, SEE APPLICABLE NOTES ON <br />TYPICAL ACCESSILIBITY NOTES SHEET. <br />D <br />SIDE REACH LIMITS <br />HIGH AND LOWCCLEAR FLOOR SPACE <br />PARALLEL APPROACH <br />E <br />MAXIMUM SIDE REACH <br />CLEAR WIDTH <br />MAX. <br />CANE RANGE <br />FIN. FLOOR LEVEL <br />THRESHOLD <br />2 <br />FIG. (A) <br />A <br />1/2" MAX. <br />PILE HEIGHT <br />TRANSITION BETWEEN FLOOR FINISHES <br />COMPRESSED CARPET 1/4" MAX. <br />BELOW THRESHOLD <br />CANE RANGE <br />1/2" MAX. <br />1/4" MAX. <br />THRESHOLD <br />LEVEL CHANGES <br />B <br />C <br />2. <br />1. <br />3. <br />NOTES: <br />CHANGE AT EDGE. <br />1/2" MAXIMUM TOTAL HEIGHT WITH 1/4" MAXIMUM VERTICAL <br />1 : 2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER <br />1/4" MAXIMUM VERTICAL LEVEL CHANGE. <br />1/4" VERITCAL LEVEL CHANGE. <br />1 <br />ANY AMOUNT <br />CANE HITS POST OR PYLON <br />BEFORE PERSON HITS OBJECT <br />OVER AN OBSTRUCTION <br />MIN <br />MIN <br />MIN <br />MAX. <br />36" MAX. <br />24" MIN. <br />7"-9" <br />33 <br />" <br />- <br />3 <br />6 <br />" <br />TO <br /> <br />T <br />O <br />P <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />9" <br /> <br />M <br />I <br />N <br />. <br />17"MIN.-19"MAX. <br />11" MIN. <br />MA <br />X <br />MAX <br />30"24" <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />46 <br />" <br /> <br />M <br />A <br />X <br />. <br />19" <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />48"MIN. <br />48" <br />48 <br />" <br />15 <br />" <br />M <br />I <br />N <br />. <br />MIN <br />X <br />48" <br />Z <br />Y <br />HI <br />G <br />H <br />E <br />R <br /> <br />T <br />H <br />A <br />N <br />LETTERS AND NUMBERS: <br />1. WIDTH TO HEIGHT RATIO BETWEEN 3 : 5 AND 1 : 1. <br />2. STROKE WIDTH TO HEIGHT BETWEEN 1 : 5 AND 1 : 10. <br />3. CONTRAST CHARACTERS AND SYMBOLS WITH BACKGROUND. <br />4. SANS SERIF CHARACTERS. <br />SIGNS: <br />5. PICTOGRAMS / PICTORIAL SYMBOL SIGNS SHALL BE ACCOMPANIED BY <br />THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE <br />PICTOGRAM. THE BORDER DIMENSION SHALL BE 6" MINIMUM HEIGHT. <br />6. CHARACTERS AND BACKGROUNDS SHALL BE OF NON-GLARE <br />CONTRASTING COLORS. <br />7. SIGNS/PICTOGRAMS SHALL BE INSTALLED ON THE LATCH SIDE OF THE <br />DOOR LEADING TO THE ROOM OF SPACE THEY DESCRIBE AND WITH A <br />CLEAR FLOOR SPACE OF 18"x18" CENTERED ON THE TACTILE <br />CHARACTERS BEYOND DOOR ARC BETWEEN 45 DEGREES AND CLOSED. <br />LOCATE ABOVE THE FLOOR PER DETAIL 1/AD1 <br />8. VERTICAL CLEARANCE AT SUSPENDED SIGNS WITH MINIMUM <br />HEADROOM OF 80" REQUIRE MINIMUM 3" CHARACTER HEIGHT <br />MEASURED BY USING UPPER CASE "X". CHARACTERS AND NUMBERS <br />SHALL BE SIZED ACCORDING TO VIEWING DISTANCE FROM WHICH <br />READ. LOWER CASE CHARACTERS PERMITTED. <br />SIGN LOCATIONS: <br />9. ALL ACCESSIBLE ENTRANCES IDENTIFIED WITH MINIMUM OF ONE <br />STANDARDS SIGN. <br />10. ADDITIONAL DIRECTIONAL SIGNS ALONG ACCESSIBLE PATH OF TRAVEL <br />ARE REQUIRED. <br />11. BUILDINGS REMODELED TO PROVIDE ACCESSIBLE SANITARY FACILITIES <br />FOR PUBLIC USE SHALL HAVE INFORMATION POSTED IN THE LOBBY AS <br />PART OF THE BUILDING DIRECTORY. <br />INTERNATIONAL SYMBOL OF ACCESSILITY: <br />12. STANDARD USED TO IDENTIFY ACCESSIBLE FACILITIES. <br />13. WHITE FIGURE ON BLUE BACKGROUND, COLOR # 15090 ON FEDERAL <br />STANDARD # 595C. <br />14. WHEN ENFORCING AGENCY DETERMINES, IF APPROPRIATE, SPECIAL <br />DESIGNS AND COLORS MAY BE APPROVED. <br />BRAILLE: <br />15. USE CONTRACTED GRADE 2 BRAILLE. DOTS TO BE 0.1" ON CENTER IN <br />EACH CELL. <br />16. 0.2" SPACE BETWEEN CELLS. <br />17. DOTS RAISED MINIMUM 0.025" ABOVE BACKGROUND. <br />18. CHARACTERS SHALL BE SANS SERIF UPPER CASE ACCOMPANIED BY <br />GRADE 2 BRAILLE ANS SIZED <br />OF ACCESSIBILITY <br />OF ACCESS <br />PLANA <br />TOILET ROOM SIGNAGE <br />DISABLED ACCESSIBILITY <br />TO COMPLY WITH TITLE 24 <br />12" <br />TYP. <br />58 <br />" <br />- <br />6 <br />0 <br />" <br />REQUIREMENTS TO <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />O <br />F <br /> <br />S <br />I <br />G <br />N <br />GEOMETRIC SYMBOLS <br />12" <br />TYP. <br />6" <br />M <br />I <br />N <br />. <br />11B-703.6.1 <br />PICTOGRAM FIELD <br />11B-703.7.2.4 <br />VOLUME CONTROL TELEPHONE <br />11B-703.7.2.3 <br />8" MIN. <br />36" (MIN.) GRAB BARS <br />FLUSH ACTIVATOR <br />ON WIDE SIDE <br />48" MIN. WHEN FRONT <br />ENTRY DOOR OR 60"MIN. <br />WHEN SIDE ENTRY DOOR <br />- WATER CLOSET SHALL BE "ULTRA LOW FLUSH" <br />TYPE WITH 1.6 GALLONS MAXIMUM PER FLUSH. <br />-TOILET ROOMS SHALL BE FINISHED WITH TILE OR <br />MARLITE OVER MOISTURE BE RESISTANT DRYWALL <br />TO A MINIMUM HEIGHT OF 4'-0" WITH 6" MIN. BASE <br />42" GRAB BAR <br />ALL SIGNS SHALL COMPLY WITH SECTION 11B-703, DIVISION 7, CHAPTER 11B OF CBC 2022 <br />60" DIA. <br />17 <br />" <br />MI <br />N <br />. <br />18" <br />MIN. <br />30"x48" <br />MIN. CLR. <br />FLR. SPACE <br />19 <br />" <br />MA <br />X <br />. <br />24" <br />MIN. <br />12" <br />MIN. <br />17"-18" <br />CL <br />60' MIN. <br />24 <br />" <br />MI <br />N <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />59 <br />" <br /> <br />M <br />I <br />N <br />. <br />4" <br />MAX. <br />.19 <br />" <br />MI <br />N <br />. <br />TOILET SEAT DISPENSER <br />(WHERE OCCURS) <br />1-1/2" DIAMETER GRAB <br />BAR W/ PEENED FINISH & <br />250 LBS. CAPACITY <br />17" TO 18" TO <br />TOP OF TOILET SEAT <br />ROLL PAPER HOLDER <br />WITHOUT STOPS <br />PROVIDE PRIVACY DOOR LOCK WHEN IT <br />IS A PRIVATE TOILET OR FOR UNISEX USE. <br />32" CLR. <br />CBC 11B-703.7.2.1 <br />12 <br />" <br /> <br />M <br />A <br />X <br />MEN MEN <br />UNISEX <br />15 <br />" <br />30" <br />48 <br />"48 <br />" <br />30 <br />" <br />48" <br />30 <br />" <br />48" <br />Z <br />X <br />80 <br />" <br /> <br />M <br />I <br />N <br />. <br />27 <br />" <br />M <br />I <br />N <br />. <br />27 <br />" <br />M <br />I <br />N <br />. <br />27 <br />" <br />M <br />I <br />N <br />. <br />27 <br />" <br />M <br />I <br />N <br />. <br />12" <br />MAX. <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />4 <br />8 <br />" <br /> <br />M <br />I <br />N <br />. <br />36" MIN. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />48" MIN. <br />32" CLEAR <br />DO <br />O <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br /> <br />P <br />L <br />U <br />S <br /> <br />4 <br />2 <br />" <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />4" <br />THE 2022 CALIFORNIA BUILDING CODE CHAPTER 11B FOR <br />ACCESSIBLE PARKING STANDARDS FOR COMMERCIAL BUILDINGS & <br />PUBLIC ACCOMMODATIONS. FOR ADDITIONAL PARKING <br />REGULATIONS PLEASE REFER TO THE LOCAL MUNICIPAL CODE FOR <br />THE REQUIREMENTS. <br />ACCESSIBLE PARKING <br />1. PARKING SPACES COMPLYING WITH SECTION 11B-502 THAT <br />SERVE A PARTICULAR BUILDING OR FACILITY SHALL BE LOCATED ON <br />THE SHORTEST ACCESSIBLE ROUTE FROM PARKING TO AN <br />ENTRANCE COMPLYING WITH SECTION 11B-206.4. WHERE PARKING <br />SERVES MORE THAN ONE ACCESSIBLE ENTRANCE, PARKING SPACES <br />COMPLYING WITH SECTION 11B-502 SHALL DISPERSED AND <br />LOCATED ON THE SHORTEST ACCESSIBLE ROUTE TO THE <br />ACCESSIBLE ENTRANCES. IN PARKING FACILITIES THAT DO NOT <br />SERVE A PARTICULAR BUILDING OR FACILITY, PARKING SPACES <br />COMPLYING WITH SECTION 11B-502 SHALL BE LOCATED ON THE <br />SHORTEST ACCESSIBLE ROUTE TO AN ACCESSIBLE PEDESTRIAN <br />ENTRANCE OF THE PARKING FACILITY. (PER 11B-208.3.1) <br />SURFACES SLOPES OF ACCESSIBLE PARKING SPACES <br />1. 11B-405.2 SLOPE - RAMP RUNS SHALL HAVE A RUNNING SLOPE <br />NOT STEEPER THAN 1:12. <br />2. 11B.405.3 CROSS SLOPE - CROSS SLOPE OF RAMP RUNS <br />SHALL NOT BE STEEPER THAN 1:48 <br />3. 11B-405.6 RISE - THE RISE OF ANY RAMP RUN SHALL BE 30" <br />MAXIMUM. <br />PARKING SPACE AND SIGNAGE <br />1. CAR AND VAN PARKING SPACES SHALL COMPLY WITH SECTION <br />11B-502. WHERE PARKING SPACES ARE MARKED WITH LINES, <br />WITH MEASUREMENTS OF PARKING SPACES AND ACCESS <br />AISLES SHALL BE MADE FROM THE CENTERLINE OF THE <br />MARKINGS (PER 11B-501.1). <br />2. CAR AND VAN PARKING SPACES SHALL BE 18' LONG MIN. CAR <br />PARKING SPACES SHALL BE 9' WIDE MIN. AND VAN PARKING <br />SPACES SHALL BE 12' WIDE MINIMUM, SHALL BE MARKED TO <br />DEFINED THE WIDTH, AND SHALL HAVE AN ADJACENT ACCESS <br />AISLE COMPLYING WITH SECTION 11B-502.3. (PER <br />11B-502.2). <br />3. ACCESS AISLES SERVING PARKING SPACES SHALL COMPLY WITH <br />SECTION 11B-502.3. ACCESS AISLES SHALL ADJOIN AN <br />ACCESSIBLE ROUTE. TWO PARKING SPACES SHALL BE <br />PERMITTED TO SHARE A COMMON ACCESS AISLE. (PER <br />11B-502.3). <br />WIDTH - ACCESS AISLE SERVING CAR AND VAN PARKING SPACE <br />SHALL BE 60" WIDE MINI. <br />LENGTH - ACCESS AISLE SHALL EXTEND THE FULL REQUIRED <br />LENGTH OF THE PARKING SPACES THEY SERVE. <br />(PER11B-502.3.2). <br />MARKING - ACCESS AISLE SHALL BE MARKED WITH A BLUE <br />PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA <br />WITHIN THE BLUE BORDERLINES SHALL BE MARKED WITH <br />HATCHED LINES A MAX. OF 36" ON CENTER IN A COLOR <br />CONTRASTING WITH THAT OF THE AISLE SURFACE, PREFERABLY <br />BLBLUE OR WHITE. THE WORDS "NO PARKING" SHALLE BE <br />PAINTED ON THE SURFACE WITHIN ACCESS AISLE IN WHITE <br />LETTERS A MIN. OF 12" IN HEIGHT & LOCATED TO BE VISIBLE <br />FROM THE ADJACENT VEHICULAR WAY. ACCESS AISLE <br />MARKINGS MAY EXTEND BEYOND THE MINIMUM REQUIRED <br />LENGTH. (PER 11B-502.3.3) <br />4. PARKING SPACE IDENTIFICATION SIGNS SHALL INCLUDE THE <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH <br />SECTION 11B-703.7.2.1. SIGNS IDENTIFYING VAN PARKING <br />SPACES SHALL CONTAIN ADDITIONAL LANGUAGE OR AN <br />ADDITIONAL SIGN WITH THE DESIGNATION "VAN ACCESSIBLE." <br />SIGNS SHALL BE 60" MIN. ABOVE FINISH FLOOR OR GROUND <br />SURFACE MEASURED TO THE BOTTOM OF THE SIGN. FINISH AND <br />SIZE - PARKING IDENTIFICATION SIGNS SHALL BE REFLECTORIZED <br />WITH A MIN. AREA OF 70 SQUARE INCHES. (PER 11B-502.6.1). <br />MINIMUM FINE - ADDITIONAL LANGUAGE OR AN ADDITIONAL <br />SIGN BELOW THE INTERNATIONAL SYMBOL OF ACCESSIBILITY <br />SHALL STATE "MINIMUM FINE $250." (PER 11B-520.6.2). <br />LOCATION - A PARING SPACE IDENTIFICATION SIGN SHALL BE <br />VISIBLE FROM EACH PARKING SPACE. SIGNS SHALL BE <br />PERMANENTLY POSTED EITHER IMMEDIATELY ADJACENT TO THE <br />PARKING SPACE OR WITHIN THE PROTECTED PARKING SPACE <br />WIDTH AT THE HEAD END OF THE PARKING SPACE. SIGNS MAY <br />ALSO BE PERMANENTLY POSTED ON A WALL AT THE INTERIOR <br />END OF THE PARKING SPACE. (PER 11B-502.6.3) <br />5. EACH ACCESSIBLE CAR AND VAN SPACE SHALL HAVE SURFACE <br />IDENTIFICATION COMPLYING WITH EITHER SECTIONS <br />11B-502.6.4.1 OR 11B-502.6.4.2. (PER 11B-502.6.4.1) <br />THE PARKING SPACE SHALL BE MARKED WITH AN INTERNATIONAL <br />SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH SECTION <br />11B-703.7.2.1IN WHITE ON A BLUE BACK GROUND A MINIMUM <br />36" WIDE BY 36" HIGH. THE CENTER LINE OF ISA SHALL BE A <br />MAXIMUM OF 6" FROM THE CENTER LINE OF THE PARKING <br />SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING <br />SPACE AND ITS LOWER CORNER AT, OR LOWER SIDE ALIGNED <br />WITH, THE END OF THE PARKING SPACE LENGTH. <br />(11B-502.6.4.1) <br />THE PARKING SPACE SHALL BE OUTLINED OR PAINTED BLUE AND <br />SHALL BE MARKED WITH AN ISA COMPLYING WITH SECTION <br />11B-703.7.2.1 A MIN. 36" WIDE BY 36" HIGH IN WHITE OR A <br />SUITABLE CONTRASTING COLOR. THE CENTERLINE OF THE ISA <br />SHALL BE A MAX. OF 6" FROM THE CENTERLINE OF THE PARKING <br />SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING <br />SPACE AND ITS LOWER CORNER AT, OR LOWER SIDE ALIGNED <br />WITH, THE END OF THE PARKING SPACE (PER 11B-502.6.4.2). <br />6. AN ADDITIONAL SIGN SHALL BE POSTED EITHER; <br />1) IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO AN OFF- <br />STREET PARKING FACILITY OR <br />2) IMMEDIATELY ADJACENT TO ON-SITE ACCESSIBLE PARKING <br />AND VISIBLE FROM EACH PARKING SPACE. (PER 11B-502.8) <br />THE SIZE OF ADDITIONAL SIGN SHALL NOT BE LESS THAN 17" <br />WIDE BY 22" HIGH. (PER 11B-502.8.1) THE LETTER OF <br />ADDITIONAL SIGN SHALL CLEARLY STATE IN LETTERS WITH A <br />MINIMUM HEIGHT OF 1" THE FOLLOWING: <br /> <br />"UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE <br />SPACE NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL <br />LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL <br />BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES <br />MAY BE RECLAIMED AT: _____ OR BY TELEPHONING ______." <br />BLANK SPACES SHALL BE FILLED IN WHICH APPROPRIATE <br />INFORMATION AS A PERMANENT PART OF THE SIGN. (PER <br />11B-502.8.2) <br />VERTICAL CLEARANCE <br />1. PARKING SPACES, ACCESS AISLES AND VEHICULAR ROUTES <br />SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE 98" <br />MINIMUM. (PER 11B-502.6) <br />E <br />KNEE CLEARANCE <br />AT DINING TABLE <br />VAN PARKING SPACES <br />1. FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES REQUIRED <br />BY SECTION 11B-208.2 TO COMPLY WITH SECTION 11B-502, AT <br />LEAST ONE SHALL BE A VAN PARKING SPACE COMPLYING WITH <br />SECTION 11B-502. (PER 11B-208.2.4). <br />EACH ACCESSIBLE CAR AND VAN SPACE SHALL HAVE SURFACE <br />IDENTIFICATION COMPLYING WITH EITHER SECTION 11B-502.6.4 OR <br />11B-502.6.4.2. <br />1. THE PARKING SPACE SHALL BE MARKED WITH AN <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING <br />WITH SECTION 11B-703-.7.2.1 IN WHITE ON A BLUE <br />BACKGROUND A MINIMUM 36" WIDE BY 36" HIGH. THE <br />CENTERLINE OF THE INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY SHALL BE A MAXIMUM OF 6" FROM THE <br />CENTERLINE OF THE PARKING SPACE, ITS SIDES PARALLEL <br />TO THE LENGTH OF THE PARKING SPACE AND ITS LOWER <br />CORNER AT, OR LOWER SIDE ALIGNED WITH, THE END OF <br />THE PARKING SPACE LENGTH. (PER 11B-502.6.4) <br />2. THE PARKING SPACE SHALL BE OUTLINED OR PAINTED BLUE <br />AND SHALL BE MARKED WITH AN INTERNATIONAL SYMBOL <br />OF ACESSIBILITY (ISA) COMPLYING WITH SECTION <br />11B-7037.2.1 A MINIMUM 36" WIDE BY 36" HIGH IN <br />WHITE OR A SUITABLE CONTRASTING COLOR. THE CENTER <br />LINE OF ISA SHALL BE A MINIMUM OF 6" FROM THE CENTER <br />OF PARKING SPACE, ITS SIDES PARALLEL TO THE LENGTH OF <br />THE PARKING SPACE & LOWER CORNER AT, OR LOWER SIDE <br />ALIGNED WITH, THE END OF THE PARKING SPACE. (PER <br />11B-502..6.4.2) <br />AN ADDITIONAL SIGN SHALL BE POSTED EITHER; <br />1) IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO AN OFF- <br />STREET PARKING FACILITY OR <br />2) IMMEDIATELY ADJACENT TO ON-SITE ACCESSIBLE PARKING <br />AND VISIBLE FROM EACH PARKING SPACE. (PER 11B-502.8) <br />THE SIZE OF ADDITIONAL SIGN SHALL NOT BE LESS THAN 17" <br />WIDE BY 22" HIGH. (PER 11B-502.8.1) THE LETTER OF <br />ADDITIONAL SIGN SHALL CLEARLY STATE IN LETTERS WITH A <br />MINIMUM HEIGHT OF 1" THE FOLLOWING: <br /> <br />"UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE <br />SPACE NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL <br />LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL <br />BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES <br />MAY BE RECLAIMED AT: _____ OR BY TELEPHONING ______." <br />BLANK SPACES SHALL BE FILLED IN WHICH APPROPRIATE <br />INFORMATION AS A PERMANENT PART OF THE SIGN. (PER <br />11B-502.8.2) <br />WALKS & SIDEWALKS: <br />GENERAL. WALKING SURFACES THAT ARE A PART OF AN <br />ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 11B-403, <br />11B-403.5.1 CLEAR WIDTH. EXCEPT AS PROVIDED IN SECTIONS <br />11B-403.5.2. AND 11B-403.5.3, THE CLEAR WIDTH OF <br />WALKING SURFACES SHALL BE 36" (914mm). <br />THE CLEAR WIDTH OF SIDEWALKS AND WALKS SHALL BE 48" <br />(219mm) MINIMUM. WHEN, BECAUSE OF "RIGHT-AWAY <br />RESTRICTIONS", NATURAL BARRIERS OR OTHER EXISTING <br />CONDITIONS, THE ENFORCING AGENCY DETERMINES THAT <br />COMPLIANCE WITH THE 48-INCH (219mm) CLEAR SIDEWALK <br />WIDTH WOULD CREATE AN UNREASONABLE HARDSHIP, THE <br />CLEAR WIDTH MAY BE REDUCED TO 36" (914mm). <br />11B-303.2 VERTICAL <br />CHANGES IN THE LEVEL OF 1/4 INCH (6.4mm) HIGH MAXIMUM <br />SHALL BE PERMITTED TO BE VERTICAL AND WITHOUT EDGE <br />TREATMENT <br />11B-303.3 BEVELED. <br />CHANGES IN LEVEL BETWEEN 1/4 INCH (6.4mm) HIGH MINIMUM <br />AND 1/2 INCH (12.7mm) HIGH MAXIMUM SHALL BE BEVELED <br />WITH A SLOPE NOT STEEPER THAN 1:2. <br />11B-403.3 SLOPE. <br />THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE <br />STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING <br />SURFACES SHALL NOT BE STEEPER THAN 1:48. <br />PROTRUDING OBJECTS <br />11B-307.2 PROTRUSION LIMITS. OBJECTS WITH LEADING <br />EDGES MORE THAN 27 INCHES (686 mm) AND NOT MORE THAN <br />80 INCHES (2032mm) ABOVE THE FINISH FLOOR OR GROUND <br />SHALL PROTRUDE 4 INCHES (102mm) MAXIMUM HORIZONTALLY <br />INTO THE CIRCULATION PATH. <br />FLOOR OR GROUND SURFACES <br />11B-302.1 GENERAL. FLOOR AND GROUND SURFACES SHALL <br />BE STABLE, FIRM, AND SLIP RESISTANT AND SHALL COMPLY <br />WITH SECTION 11B-302. <br />11B-302.2 CARPET OR CARPET TILE SHALL BE SECURELY <br />ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR <br />BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE <br />SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVELCUT PILE, <br />LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE 1/2 INCH <br />(12.7MM) MAXIMUM. EXPOSED EDGES OR CARPET SHALL BE <br />FASTENED TO FLOOR SURFACE AND SHALL HAVE TRIM ON THE <br />ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM <br />SHALL COMPLY WITH SECTION 11B-303. <br />11B-302.3 OPENINGS. OPENINGS IN FLOOR OR GROUND <br />SURFACES SHALL NOT, ALLOW PASSAGE OF A SYPHERE MORE <br />THAN 1/2 INCH (12.7 MM) DIAMETER EXCEPT AS ALLOWED IN <br />SECTION 11B-407.4.3 <br />11B-303.2 VERTICAL. CHANGES IN LEVEL GREATER THAN 1/4 <br />INCH (6.4 MM) AND NOT EXCEEDING 1/2 IN HEIGHT SHALL BE <br />BEVELED WITH A SLOPE NOT STEEPER THEN 1:2 (11B-303) & <br />(11B-303.3). <br />SANITARY FACILITIES (GENERAL): <br />11B-703.7.2.6.3 UNISEX TOILET AND BATHING FACILITIES. <br />UNISEX TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY <br />A CIRCLE, 1/4 INCH (6.4mm) THICK AND 12 INCHES (305mm) IN <br />DIAMETER WITH A 1/4 INCH (6.4mm) THICK TRIANGLE WITH A <br />VERTEX POINTING UPWARD SUPERIMPOSED ON THE CIRCLE AND <br />WITHIN THE 12-INCH (305mm) DIAMETER. THE TRIANGLE <br />SYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER <br />LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT <br />BACKGROUND. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE <br />DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A <br />LIGHT BACKGROUND. <br />SANITARY FACILITY FIXTURES & ACCESSORIES: <br />11B-606.5 EXPOSED PIPES AND SURFACES. <br />WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS <br />SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT <br />AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE <br />SURFACES UNDER LAVATORIES AND SINKS. <br />11B-703.7.2.6 TOILET AND BATHING FACILITIES GEOMETRIC <br />SYMBOLS. DOORWAYS LEADING TO TOILET ROOMS AND BATHING <br />ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL <br />COMPLYING WITH SECTION 11B-703.7.2.6. THE SYMBOL SHALL BE <br />MOUNTED AT 58 INCHES (1473mm) MINIMUM AND 60 INCHES <br />(1524mm) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND <br />SURFACE MEASURED FROM THE CENTERLINE OF THE SYMBOL. <br />WHERE A DOOR IS PROVIDED THE SYMBOL SHALL BE MOUNTED <br />WITHIN 1 INCH (25mm) OF THE VERTICAL CENTERLINE OF THE <br />DOOR. <br />11B-703.4.1. HEIGHT ABOVE FINISH FLOOR OR GROUND. <br />TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES <br />(1219mm) MINIMUM ABOVE THE FINISH FLOOR OR GROUND <br />SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST <br />BRAILLE CELLS AND 60 INCHES (1524mm) MAXIMUM ABOVE THE <br />FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE <br />BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. <br />DOOR, DOORWAYS, AND GATES <br />1. DOORS, DOORWAYS, AND GATES THAT ARE PART OF AN <br />ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION (11B-404.1) <br />2. MANUAL DOORS, DOORWAYS, AND MANUAL GATES INTENDED FOR <br />USER PASSAGE SHALL COMPLY WITH SECTION 11B-504.2 (PER <br />11B-404.2) <br />3. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32" MIN. <br />CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE <br />MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH <br />THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24" DEEP <br />SHALL PROVIDE A CLEAR OPENING OF 36" MIN. THERE SHALL BE NO <br />PROJECTION INTO THE REQUIRED CLEAR OPENING WIDTH LOWER <br />THAN 34" ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS <br />INTO THE CLEAR OPENING WIDTH BETWEEN 34" AND 80" ABOVE <br />THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4". (PER <br />11B-404.2.3) <br />4. SWINGING DOORS AND GATES SHALL HAVE MANEUVERING <br />CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.1. <br />5. RECESSED DOORS & GATES SHALL HAVE MANEUVERING <br />CLEARANCES FORWARD APPROACH AND SHALL BE PROVIDED WHEN <br />ANY OBSTRUCTION WITHIN 18" OF THE LATCH SIDE AT AN INTERIOR <br />DOORWAY, OR WITHIN 24" OF THE LATCH SIDE OF AN EXTERIOR <br />DOORWAY, PROJECTS MORE THAN 8" BEYOND THE FACE OF THE <br />DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR <br />GATE. (PER 11B-404.2.4.3) <br />6. FLOOR OR GROUND SURFACE WITHIN REQUIRED MANEUVERING <br />CLEARANCES SHALL COMPLY WITH SECTION 11B-302. CHANGES IN <br />LEVEL ARE NOT PERMITTED. (PER 11B-404.2.4.4) <br />7. PROVIDED THRESHOLD AT DOORWAYS SHALL BE 1/2" HIGH MAX. <br />RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS <br />SHALL COMPLY WITH SECTIONS11B-302 & <br />11B-303.(PER11B-404.2.5) <br />8. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS <br />ON DOORS AND GATES SHALL COMPLY WITH SECTION 11B-309.4. <br />OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MINI. AND <br />44" MAX. ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING <br />DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE <br />SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. (PER <br />11B-404.2.7) <br />9. DOOR & GATE CLOSING SPEED SHALL COMPLY WITH SECTION <br />11B-404.2.8. <br />THE DOOR & GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM <br />AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE <br />THE DOOR TO A POSITION OF 12 DEGREES FROM THE LARCH IS 5 <br />SECONDS MINIMUM. (PER 11B-404.2.8.1). <br />DOOR & GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM <br />THE OPEN POSITION OF 70 DEGREES, THE DOOR OR GATE SHALL <br />MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MIN. (PER <br />11B-404.2.8.2). <br />10. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OR <br />OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: <br />A. INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAX. <br />B. SLIDING OR FOLDING DOORS: 5 POUNDS MAX. <br />C. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE <br />ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, <br />NOT TO EXCEED 15 POUNDS. <br />THE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT <br />LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE <br />DOOR OR GATE IN A CLOSED POSITION. (PER 11B-404.2.9). <br />11. SWINGING DOOR AND GATE SURFACES WITHIN 10" OF THE <br />FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A <br />SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL <br />WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL <br />OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16" <br />OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR <br />ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE <br />CAPPED. (PER 11B-404.2.10). <br />12. AUTOMATIC DOORS & AUTOMATIC GATES SHALL COMPLY WITH <br />SECTION 11B-404.3. FULL-POWERED AUTOMATIC DOORS SHALL <br />COMPLY WITH ANSI/BHMA A156.10. LOW-ENERGY AND <br />POWERASSISTED DOORS SHALL COMPLY WITH ANSI/BHMA <br />A156.19. (PER 11B-404.3) <br />13. WHERE DOORS & GATES WITHOUT STANDBY POWER ARE A PART <br />OF A MEANS OF EGRESS, THE CLEAR BREAK OUT OPENING AT <br />SWINGING OR SLIDING DOORS AND GATES SHALL BE 32" MIN. <br />WHEN OPERATED IN EMERGENCY MODE. (PER 11B-404.3.6) <br />HANDRAILS & GRAB BARS <br />1. HANDRAIL GRIPPING SURFACES WITH A CIRCULAR CROSS SECTION <br />SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/4" MIN. AND 2" MAX. <br />(PER 11B-505.7.1) <br />HANDRAIL GRIPPING SURFACES AND ANY SURFACES ADJACENT TO <br />THEM SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS AND <br />SHALL HAVE ROUNDED EDGES (PER 11B-505.8) <br />2. GRAB BARS WITH CIRCULAR CROSS SECTIONS SHALL HAVE AN <br />OUTSIDE DIAMETER OF 1 1/4" MIN. AND 2" MAX. (PER <br />11B-606.2.1) <br />GRAB BARS AND ANY WALL OR OTHER SURFACES ADJACENT TO <br />GRAB BARS SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS <br />AND SHALL HAVE ROUNDED EDGES. (PER 11B-609.5) <br />COMMUNICATION ELEMENTS <br />FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED <br />AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72 & <br />CHAPTER 9, SECTION 907.5.2.1 AND 907.5.2.3 (PER <br />11B-702.10) <br />1. ALL BUILDING ENTRANCES SHALL BE IDENTIFIED WITH SIGNS <br />THAT COMPLY WITH WITH SECTION 11B-703. WHERE BOTH <br />VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS, <br />ONE WITH VISUAL, AND ONE WITH TACTILE CHARACTERS. SHALL <br />BE PROVIDED. (PER 11B-703.1) <br />2. SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH <br />SECTION 11B-703.4 & 11B-703.4.1 <br />3. RAISED CHARACTERS SHALL BE 1/32" MIN. ABOVE THEIR <br />BACKGROUND. 11B-703.2.1 <br />4. CHARACTERS SHALL BE UPPERCASE. 11B-703.2.2 <br />5. CHARACTERS SHALL BE SAN SERIF. CHARACTERS SHALL NOT BE <br />ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER <br />UNUSUAL FORMS. 11B-703.2.3 <br />6. CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE <br />WIDTH OF THE UPPERCASE LETTER "O" IN 55 60 PERCENT MIN. <br />AND 110 PERCENT MAX. OF THE HEIGHT OF THE UPPERCASE <br />LETTER "I". 11B-703.2.4 <br />7. CHARACTERS HIGH MEASURED VERTICALLY FROM THE BASELINE <br />OF THE CHARACTER SHALL BE 5/8" MIN. AND 2" MAX. BASED ON <br />THE HEIGHT OF THE UPPERCASE LETTER "I". 11B-703.2.5. <br />8. STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 15 <br />PERCENT MAX. OF THE HEIGHT OF THE CHARACTER. <br />11B-703.2.6. <br />9. CHARACTERS SPACING SHALL BE MEASURED BETWEEN THE TWO <br />CLOSEST POINTS OF ADJACENT RAISED CHARACTERS WITHIN A <br />MESSAGE, EXCLUDING WORD SPACES. WHERE CHARACTERS <br />HAVE RECTANGULAR CROSS SECTIONS, SPACING BETWEEN <br />INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8" MIN. AND 4 <br />TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM. <br />WHERE CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING <br />BETWEEN INDIVIDUAL RAISED CHARACTER SHALL BE 1/16" MIN. <br />AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAX. AT <br />THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE <br />SEPARATED FROM RAISED BORDERS AND DECORATIVE <br />ELEMENTS 3/8" MIN. 11B-703.2.7 <br />10. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF <br />RAISED CHARACTERS WITHIN A MESSAGE SHALL BE 135% MIN. <br />AND 170% MAX. OF THE RAISED CHARACTER HEIGHT. <br />11B-703.2.8 <br />11. TEXT SHALL BE IN A HORIZONTAL FORMAT. 11B-703.2.9 <br />12. BRAILLE SHALL BE CONTRACTED (GRADE 2 ) AND SHALL COMPLY <br />WITH SECTION 11B-703.3 BRAILLE AND 11B-703.4 <br />INSTALLATION HEIGHT AND LOCATION 11B-703.3 <br />13. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND <br />SHALL COMPLY WITH TABLE 11B-703.3.1. THE INDICATION OF <br />AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED <br />BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND <br />NAMES, INDIVIDUAL LETTERS OF THE ALPHABET INITIALS, AND <br />ACRONYMS. 11B-703.3.1 <br />14. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING <br />TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR CENTERED. IF <br />TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE <br />ENTIRE TEXT. BRAILLE SHALL BE SEPARATED 3/8" MIN. AND 1/2" <br />MAX. FROM ANY OTHER TACTILE CHARACTERS AND 3/8" MIN. <br />FROM RAISED BORDERS AND DECORATIVE ELEMENTS. <br />11B-703.3.2 (SEE EXCEPTION). <br />15. SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH <br />11B-703.4 INSTALLATION HEIGHT AND LOCATION. 11B-703.4 <br />16. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48" MIN. <br />ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED <br />FROM THE BASELINE OF THE LOWEST TACTILE CHARACTER <br />BRAILLE CELLS AND 60" MAX. ABOVE THE FINISH FLOOR OR <br />GROUND SURFACE, MEASURED FROM THE BASELINE OF THE <br />HIGHEST TACTILE CHARACTER LINE RAISED CHARACTERS. <br />11B-703.4.1 (SEE EXCEPTION) <br />17. WHERE A TACTILE SIGN IS PROVIDED AT DOOR, THE SIGN SHALL <br />BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE <br />A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE <br />ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE <br />LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS <br />WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE <br />RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL <br />SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT <br />SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE <br />NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE <br />CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR <br />SPACE OF 18" MIN. BY 18" MIN, CENTERED ON THE TACTILE <br />CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR <br />SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN <br />POSITION. WHERE PERMANENT IDENTIFICATION SIGNAGE IS <br />PROVIDED FOR ROOMS AND SPACES THEY SHALL BE LOCATED <br />ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE <br />ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL BE <br />LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE <br />ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS <br />SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS <br />ONE EXITS THE ROOM OR SPACE. 11B-703.4.2 (SEE <br />EXCEPTION) <br />18. VISUAL CHARACTERS SHALL COMPLY WITH THE FOLLOWING, <br />EXCEPT WHERE VISUAL CHARACTERS COMPLY WITH 11B-703.2 <br />RAISED CHARACTERS AND ARE ACCOMPANIED BY BRAILLE <br />COMPLYING WITH 11B-703.3 BRAILLE, THEY SHALL NOT BE <br />REQUIRED TO COMPLY WITH 11B-703.5.2 THROUGH <br />11B-703.5.6,11B-703.5.8 AND 11B-703.5.9 <br />ELECTRICAL: <br />(11B-308.1.1) ELECTRICAL SWITCHES. CONTROLS AND SWITCHES <br />INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREAS <br />TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR <br />COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL COMPLY <br />WITH SECTION 11B-308 EXCEPT THE LOW REACH SHALL BE <br />MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH <br />REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. <br />(11B-308.1.2) ELECTRICAL RECEPTACLE OUTLETS. ELECTRICAL <br />RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR <br />LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL COMPLY <br />WITH SECTION 11B-308 EXCEPT THE LOW REACH SHALL BE <br />MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH <br />REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. <br />OPERABLE PARTS: <br />(11B-309.4) OPERATION. OPERABLE PARTS SHALL BE OPERABLE <br />WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, <br />PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO <br />ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM. <br />JOB# <br />DATE <br />DRAWN <br />SCALE <br />Th <br />i <br />s <br /> <br />D <br />u <br />c <br />o <br />u <br />m <br />e <br />n <br />t <br /> <br />i <br />s <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />Y <br />N <br /> <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C. <br />, <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />be <br /> <br />r <br />e <br />p <br />o <br />r <br />d <br />u <br />c <br />e <br />d <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />c <br />o <br />n <br />s <br />e <br />n <br />t <br /> <br />o <br />f <br /> <br />Y <br />N <br />G <br /> <br />A <br />R <br />CH <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C <br />. <br />© <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />No. C-32798 <br />HC <br />F <br />RADSEN <br />E <br />S <br />TAT <br />LCAIOF <br />E <br />ILC <br />A <br />ORNI <br />TC <br />ITEYENNY NG <br />DATE <br />RENEWAL <br />03-31-25 <br />1/4" = 1'-0" <br />A0.2 <br />AC <br />C <br />E <br />S <br />S <br />I <br />B <br />I <br />L <br />I <br />T <br />Y <br /> <br />N <br />O <br />T <br />E <br />S <br />YC23005 <br />AN <br />C <br />E <br />N <br />A <br />Y <br /> <br />C <br />O <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />JAN 2024 <br />T.N. <br />21 <br />0 <br /> <br />W <br />. <br /> <br />1 <br />9 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />Da <br />t <br />e <br /> <br />D <br />e <br />s <br />c <br />r <br />i <br />p <br />t <br />i <br />o <br />n <br />ACCESSIBILITY NOTES <br />2DOORS4PRIVACY/UNISEX TOILET ROOM7SIGNS/PICTOGRAMS <br />1DOOR CLEAR SPACE3REACH REQUIREMENTS5THREDSHOLDS/LEVEL CHANGE <br />6PROTRUDING OBJECTS <br />210 W 19th St <br />4/14/2025