WINDOW FRAME - INSTALL PER <br />MANUFACTURER'S INSTRUCTIONS <br />1/2" PLY. SHEATHING <br />WATER PROOFING MEMBRANE <br />(N) 8-1/4" JAMES HARDIE <br />PLANK BOARD <br />INTERIOR FINISH <br />WHERE OCCURS <br />INSULATION <br />WHERE OCCURS <br />ACCENT TRIM <br />2x SILL <br />FLASHING <br />CAULK <br />MI <br />N <br />. <br /> <br />1 <br />/ <br />4 <br />" <br /> <br />O <br />V <br />E <br />R <br />L <br />A <br />P <br />INSULATION WHERE OCCURS <br />2x FRAMING - REFER TO STRUCTURAL DRAWINGS <br />INTERIOR FINISH WHERE OCCURS <br />WINDOW FRAME - INSTALL PER MANUFACTURER'S INSTRUCTIONS <br />1/2" PLY. SHEATHING <br />WATERPROOF MEMBRANE <br />(N) JAMES HARDIE PLANK BOARDCAULK <br />ACCENT TRIM <br />NOTE: REFER TO MANUFACTURER'S <br />SPECIFICATIONS FOR INSTALLATION <br />OF HARDIE PANELS <br />WINDOW FRAME - INSTALL <br />PER MANUFACTURER'S <br />INSTRUCTIONS <br />INSULATION <br />INTERIOR FINISH <br />WINDOW HEADER - <br />REFER TO STRUCTURAL <br />DRAWINGS <br />WHERE OCCURS <br />WHERE OCCURS <br />(N) JAMES HARDIE PLANK BOARD <br />WATERPROOF MEMBRANE <br />1/2" PLY. SHEATHING <br />STARTER STRIP <br />FLASHING <br />CAULK <br />ACCENT TRIM <br />WOOD CASING <br />2x4 FRAMING AT DOOR - <br />INTERIOR FINISH WHERE OCCURS <br />INSULATION WHERE OCCURS <br />WOOD DOOR FRAME <br />WEATHERSTRIP <br />CAULK <br />REFER TO STRUCT. DRAWINGS <br />1/2" PLY. SHEATHING <br />SHIM SPACE <br />DOOR <br />WATERPROOF MEMBRANE <br />(N) JAMES HARDIE PLANK BOARD <br />ACCENT TRIM <br />NOTE: REFER TO MANUFACTURER'S <br />SPECIFICATIONS FOR INSTALLATION <br />OF HARDIE PANELS <br />(N) JAMES HARDIE PLANK BOARD <br />DOOR HEADER - <br />INTERIOR FINISH <br />INSULATION <br />WOOD CASING <br />WEATHERSTRIP <br />DOOR WOOD DOOR FRAME <br />WATERPROOF MEMBRANE <br />REFER TO STRUCT. <br />DRAWINGS <br />WHERE OCCURS <br />WHERE OCCURS <br />SHIM SPACE <br />1/2" PLY. SHEATHING <br />STARTER STRIP <br />FLASHING <br />CAULK <br />ACCENT TRIM <br />(N) JAMES HARDIE PLANK BOARD <br />INTERIOR FINISH <br />1/2" PLY. SHEATHING <br />2x FRAMING - REFER TO <br />STRUCTURAL DRAWINGS <br />WHERE OCCURS <br />INSULATION <br />WHERE OCCURS <br />WATER PROOF MEMBRANE <br />CAULK <br />ACCENT TRIM <br />NOTE: REFER TO MANUFACTURER'S <br />SPECIFICATIONS FOR INSTALLATION <br />OF HARDIE PANELS <br />DOOR <br />DOOR FRAME BEYOND <br />CONCRETE SLAB - REFER TO <br />STRUCTURAL DRAWINGS <br />BULB WEATHERSTRIPPING & FIN SWEEP <br />OR APPROVED EQUAL PER DOOR MFR. <br />ADJUSTABLE SILL & SILL COVER BY <br />"THERMATRU" OR APPROVED EQUAL - <br />INSTALL PER MFR'S. INSTRUCTIONS <br />STUCCO COLOR COAT AT SLAB AREA <br />PRIOR TO PLACEMENT OF THRESHOLD <br />CONCRETE FLATWORK <br />SLOPE 1/4":12" MIN. <br />METAL PRODUCTS SHALL BE ISOLATED FROM <br />DISSIMILAR OR CORROSIVE MATERIALS WITH A <br />NONCONDUCTIVE COATING OR SEALANT MATERIAL <br />PAN FLASHING/ SILL GUARD - INSTALL <br />PER MANUFACTURER'S INSTRUCTIONS <br />7 <br />3 <br />/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />INSULATION <br />WHERE OCCURS <br />INTERIOR FINISH <br />WHERE OCCURS <br />FINISH GRADE <br />FLATWORK WHERE OCCURS <br />2x P.T. SILL PLATE <br />(N) JAMES HARDIE PLANK BOARD <br />1/2" SHEATHING <br />SLOPE <br />6" <br /> <br />U <br />. <br />N <br />. <br />O <br />. <br />8" <br /> <br />M <br />I <br />N <br />. <br />CONCRETE <br />FOUNDATION - REFER TO <br />STRUCTURAL DWGS <br />STARTER STRIP <br />WATERPROOF MEMBRANE <br />1 SILL FLASHING <br />JAMB FLASHING2 <br />WINDOW INSTALLATION3 <br />SURFACE PREPARATION4 <br />JAMB FLASHING5 <br />HEAD FLASHING6 <br />1 <br />2 <br />2 <br />3 <br />4 <br />5 <br />6 <br />A <br />B <br />C WINDOW <br />D WINDOW FLANGE <br />F <br />E <br />A <br />D <br />B <br />E <br />HEAD FLASHING <br />JAMB FLASHING <br />WINDOW <br />WINDOW OPENING <br />SILL / JAMB FLASHING <br />CUT A STRIP OF MOISTOP E-Z SEAL FOR THE <br />HEAD (F) OF THE WINDOW, EXTENDING BEYOND <br />THE JAMB FLASHING IN PLACE. PLACE THE <br />MOISTOP E-Z SEAL ON THE TOP OF THE FLANGE <br />(D) OF THE WINDOW AND SEAL BY APPLYING <br />PRESSURE ALONG THE STRIP. <br />CUT A STRIP OF MOISTOP E-Z SEAL FOR THE <br />JAMB (E) OF THE WINDOW, EXTENDING BEYOND <br />THE FLANGE (3" MINIMUM TOP AND BOTTOM). <br />PLACE THE MOISTOP E-Z SEAL ON THE TOP OF <br />THE FLANGE (D) OF THE WINDOW AND SEAL BY <br />APPLYING PRESSURE ALONG THE STRIP. REPEAT <br />FOR OTHER JAMB. <br />WIPE THE WINDOW FLANGE (D) AND BASE <br />MOISTOP PF FLASHING (B) LAYER CLEAN BEFORE <br />APPLYING MOISTOP E-Z SEAL. CUT THE DESIRED <br />LENGTH OF MOISTOP E-Z SEAL WITH A SHARP <br />KNIFE. PULL OFF THE RELEASE PAPER AND PLACE <br />THE MOISTOP E-Z SEAL ON TOP OF THE WINDOW <br />FLANGE. APPLY FIRM PRESSURE ALONG THE <br />ENTIRE SELF ADHESIVE STRIP TO ENSURE A <br />CONTINUOUS SEAL. <br />BEFORE INSTALLING THE WINDOW (C), APPLY A <br />CONTINUOUS 3/8" BEAD OF MOISTOP SEALANT <br />TO THE PERIMETER OF THE ROUGH OPENING <br />OR TO THE BACKSIDE OF THE MOUNTING <br />FLANGE (D) OF THE WINDOW. INSTALL THE <br />WINDOW ACCORDING TO THE WINDOW <br />MANUFACTURER'S INSTRUCTIONS. <br />CUT STRIP OF MOISTOP PF FLASHING LONG <br />ENOUGH TO EXTEND BEYOND SILL FLASHING <br />ALREADY IN PLACE, AND ABOVE WHERE THE <br />MOISTOP E-Z SEAL HEAD FLASHING WILL <br />INTERSECT. NEXT ATTACH THE JAMB FLASHING <br />(B) FLUSH TO THE EDGE OF THE ROUGH <br />OPENING LEAVING THE BOTTOM FREE. REPEAT <br />THE STEPS FOR THE REMAINING JAMBS. <br />ONCE THE ROUGH OPENING IS PREPARED, <br />PROCEED BY ATTACHING MOISTOP PF FLASHING <br />(A) FLUSH ALONG THE BOTTOM OF THE ROUGH <br />OPENING, BE SURE NOT TO FASTEN THE LOWER <br />EDGE OF THE FLASHING SO THAT JUMBO TEX, <br />FORTIY OR WEATHERSMART MAY BE SLIPPED UP <br />UNDERNEATH THE FLASHING IN A <br />WEATHERBOARD FASHION, EXTEND THE BEYOND <br />THE JAMB FLASHING TO BE APPLIED LATER. <br />USE 12" MOISTOP E-Z <br />SEAL FOR HEAD <br />INSTALLATION <br />MOISTOP <br />E-Z SEAL <br />HEAD <br />FLASHING <br />6" MOISTOP E-Z <br />SEAL JAMB <br />FLASHING <br />USE 6" MOISTOP <br />E-Z SEAL FOR JAMB <br />FLASHING <br />THE JAMB FLASHING <br />SHOULD EXTEND <br />ABOVE WHERE THE <br />MOISTOP E-Z SEAL <br />HEAD FLASHING WIL <br />INTERSECT. <br />9" MOISTOP PF <br />FLASHING BASE JAMB <br />EXTEND JAMB FLASHING <br />BEYOND THE SILL <br />FLASHING. LEAVE FLASHING <br />FREE AT BOTTOM <br />THE BASE LAYER OF <br />MOISTOP PF FLASHING DOES <br />NOT HAVE HEAD FLASHING. <br />INSTALL MOISTOP PF FLASHING <br />FLUSH WITH THE SILL OF THE <br />ROUGH OPENING <br />9" MOISTOP <br />PF FLASHING <br />BASE SILL <br />(M <br />I <br />N <br />. <br />) <br />6" <br />(MIN.) <br />6" <br />CORNER BEAD - (TYP.) <br />EXTERIOR PLASTER <br />PLYWOOD SHTG.- (TYP.) <br />STEEL STUD <br />SELF ADHERED FLASHING, <br />(TYP.) <br />JOB# <br />DATE <br />DRAWN <br />SCALE <br />Th <br />i <br />s <br /> <br />D <br />u <br />c <br />o <br />u <br />m <br />e <br />n <br />t <br /> <br />i <br />s <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />Y <br />N <br /> <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C. <br />, <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />be <br /> <br />r <br />e <br />p <br />o <br />r <br />d <br />u <br />c <br />e <br />d <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />c <br />o <br />n <br />s <br />e <br />n <br />t <br /> <br />o <br />f <br /> <br />Y <br />N <br />G <br /> <br />A <br />R <br />CH <br />I <br />T <br />E <br />C <br />T <br />S <br />, <br /> <br />I <br />N <br />C <br />. <br />© <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />No. C-32798 <br />HC <br />F <br />RADSEN <br />E <br />S <br />TAT <br />LCAIOF <br />E <br />ILC <br />A <br />ORNI <br />TC <br />ITEYENNY NG <br />DATE <br />RENEWAL <br />03-31-25 <br />As indicated <br />AD2 <br />AR <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br />S <br />YC23005 <br />AN <br />C <br />E <br />N <br />A <br />Y <br /> <br />C <br />O <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />JAN 2024 <br />T.N. <br />21 <br />0 <br /> <br />W <br />. <br /> <br />1 <br />9 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />SCALE <br />3" = 1'-0"7WINDOW SILL <br />SCALE <br />3" = 1'-0"9WINDOW JAMB <br />SCALE <br />3" = 1'-0"8WINDOW HEAD SCALE <br />3" = 1'-0"5DOOR JAMB <br />SCALE <br />3" = 1'-0"4EXTERIOR DOOR HEAD <br />SCALE <br />3" = 1'-0"6CORNER HARDIE PANEL <br />SCALE <br />3" = 1'-0"1DOOR THRESHOLD <br />SCALE <br />3" = 1'-0"2WEEP CREED <br />SCALE <br />1/4" = 1'-0"10WINDOW FLASHING <br />SCALE <br />3" = 1'-0"3CORNER DETAIL <br />Da <br />t <br />e <br /> <br />D <br />e <br />s <br />c <br />r <br />i <br />p <br />t <br />i <br />o <br />n <br />210 W 19th St <br />4/14/2025