Laserfiche WebLink
Design Criteria Lee & Lee Structural Engineering Inc. <br />Building Code CBC 2022 <br />Project Address 210 W 19th st Santa Ana 92706 <br />Latitude 33.7616084 Longitude Decimal <br />Project Type House <br />Seismic Force Resisting System <br />Light-framed wall sheathed with wood structural panels ASCE 7-16, Table 12.2-1 <br />R =6.5 Response Modification Coefficient <br />Ω o =3.0 System Overstrength Factor <br />C d =4.0 Deflection Amplification Factor <br />Cantilevered column systems <br />R =1.5 Response Modification Coefficient <br />Ω o =1.5 System Overstrength Factor <br />C d =1.5 Deflection Amplification Factor <br />Material <br />Concrete <br />F'c =3500 psi for Slab-on Grade & Footing 22-1199p p.10 <br />Reinforcing Steel <br />ASTM A615 GR60 & GR40 <br />Foundation System <br />Allowable Soil Bearing Pressure 22-1199p p.8 <br />F p =2000 psf for Isolation Pad & Continuous <br />min 18" depth <br />-117.8689459 <br />Design Criteria <br />2 of 81 <br />210 W 19th St <br />4/14/2025