Laserfiche WebLink
<br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />#6 AND LARGER <br />#5 AND SMALLER <br />A. POURED AGAINST EARTH <br />B. POURED AGAINST FORM BELOW GRADE <br />2'' <br />1 1/2'' <br />3'' <br />2'' <br />REINFORCING STEEL <br />GLULAMS/MFR. WD. PROD. <br />D. SLABS ON GRADE (FROM TOP OF SLAB) <br />E. COLUMNS AND BEAMS TO MAIN BARS <br />F. WALLS - EXPOSED TO WEATHER NOT <br />EXPOSED TO WEATHER, #11 AND SMALLER <br />CONCRETE <br />STRUCTURAL STEEL <br />GENERAL NOTES <br />C. FORMED SLABS <br />LUMBER/CARPENTRY <br />1 1/2'' <br />#14 AND #18 1 1/2" <br />1'' <br />1''FOUNDATION/SITEWORK <br />4X16 #1: Fb= 1000 PSI <br />SINGLE/REPETITIVE <br />6 <br />2X6 #2: Fb= 1170/1345 PSI <br />2X8 #2: Fb= 1080/1242 PSI <br />2X10 #2: Fb= 990/1138 PSI <br />2X12 #2: Fb= 900/1150 PSI <br />2X14 #2: Fb= 810/ 931 PSI <br />4X6 #2: Fb= 1170 PSI <br />4X8 #2: Fb= 1170 PSI <br />4X10 #2: Fb= 1080 PSI <br />4X14 #1: Fb= 1000 PSI <br />6X12 #1: Fb= 1350 PSI <br />4X12 #1: Fb= 1100 PSI ; Fv=180 psi E= 1.7x10 <br />2X4 #2: Fb= 1350/1552 PSI ; Fv=180 psi E=1.6x10 <br />4X4 #2: Fb= 1350 PSI <br />2018 NDS STRESS VALUES FOR DOUGLAS FIR-LARCH: <br />CONC. <br />2'' <br />2'' <br />3/4" <br />MASONRY <br />2'' <br />1 1/2'' <br />1 1/2'' <br />1 1/2" <br />2'' <br />1'' <br />1'' <br />3/4" <br />1 1/2" <br />6X10 #1: Fb= 1350 PSI ; Fv=170 psi, E=1.6x10 <br />LUMBER/CARPENTRY (cont.) <br />DESIGN LOADS: <br />SHEET INDEX: <br />S.0 STRUCTURAL GENERAL NOTES <br />S.1 FOUNDATION PLAN <br />S.2 ROOF FRAMING PLAN <br />SD1 FOUNDATION DETAILS <br />SD2 STRUCTURAL DETAILS <br />NAILING SCHEDULE <br />SEISMIC DESIGN DATA <br />IMPORTANCE FACTOR 1.0 <br />SITE CLASS D <br />SS 1.313 <br />S1 0.468 <br />SDS 1.05 <br />SD1 NULL <br />SDC D <br />LATERAL FORCE RESISTING SYSTEM 15 <br />BASE SHEAR <br />CS 0.146 <br />R 6.5 <br />W 2.50 <br />PROCEDURE USED ELF <br />REDUNDANCY FACTOR 1.3 <br />WIND DESIGN <br />PROCEDURE USED MWFRS <br />BASIC WIND SPEED 95 MPH <br />RISK CATEGORY II <br />WIND EXPOSURE C <br />SOIL <br />SOIL REPORT PREPARED BY <br />PROJECT NUMBER <br />DATE <br />SOIL BEARING PRESSURE 1500 PSF <br />VERTICAL <br />11 PSF <br />ROOF RAFTER LL = <br />ROOF RAFTER DL = <br />20 PSF <br />15 PSF <br />INT. WALL DL = 10 PSF <br />EXT. WALL DL = <br />( CBC 2022 ) <br />CEILING JOIST LL = <br />CEILING JOIST DL = 4 PSF <br />10 PSF <br />TYPICAL FLOOR/ROOF DECK/DECK SHEATHING <br />TYPICAL SLOPED/FLAT NON-ASSEMBLY ROOF SHEATHING <br />HORIZONTAL DIAPHRAGM: <br />6 <br />6 <br />12.ALL NAILING TO BE PER TABLE NUMBER 2304.9.1 OF THE LATEST <br />CALIFORNIA BUILDING CODE (CBC), UNLESS NOTED OTHERWISE. <br />13.PLYWOOD FLOOR AND ROOF SHEATHING SHALL BE LAID CONTINUOUS <br />OVER TWO OR MORE SUPPORTS WITH FACE GRAIN PERPENDICULAR TO <br />SUPPORTS (UNLESS SHOWN OTHERWISE). STAGGER ALL PLYWOOD <br />PANELS A MINIMUM OF 4'-0". <br />14.FLOOR SHEATHING TO BE NAILED AND GLUED TO THE JOISTS. USE <br />ADHESIVES PER A.P.A. AFG-01 OR ASTM D3498. <br />15.FRAMING CONTRACTOR SHALL PROVIDE BACKING AS REQUIRED FOR <br />ALL LIGHT FIXTURES, CABINETS, WARDROBES, TOWEL BARS, AND <br />HANDRAILS AS REQUIRED AND REQUESTED BY GENERAL CONTRACTOR. <br />16.EXTERIOR WOOD POSTS AND COLUMNS SUPPORTED BY A CONCRETE <br />SLAB SHALL BE INSTALLED A MINIMUM OF 8" ABOVE EXPOSED EARTH <br />AND AT LEAST 1" ABOVE SLAB ON METAL POST BASES. (EXCEPTION: <br />POSTS OR COLUMNS OF APPROVED WOOD WITH NATURAL RESISTANCE <br />TO DECAY OR TREATED WOOD). POSTS OR COLUMNS RESTING ON <br />CON-CRETE PIERS SURROUNDED BY EXISTING GRADE SHALL BE A <br />MINIMUM OF 8" ABOVE ADJACENT GRADE PER CBC (LATEST EDITION). <br />ALL ISOLATED INTERIOR AND EXTERIOR WOOD POSTS ATTACHED <br />DIRECTLY TO CONCRETE SHALL BE SECURED WITH SIMPSON 'ABU', <br />U.N.O. <br />17.PROVIDE 2x4 FLAT HEADERS AT ALL INTERIOR NON-BEARING OPENINGS <br />UP TO 36 INCHES IN WIDTH AND 4x4 HEADERS FOR OPENINGS 3 ft TO 6 ft <br />IN WIDTH. <br />18.PROVIDE MINIMUM 1/2" CLEARANCE (VOID SPACE) FROM TOP OF ALL <br />INTERIOR NON-BEARING PARTITIONS TO ROOF AND CEILING FRAMING <br />ABOVE. <br />19.ALL EXTERIOR WALLS ADJACENT TO VAULTED CEILINGS SHALL BE <br />BALLOON FRAMED WITH CONTINUOUS STUDS TO BOTTOM CHORD OF <br />TRUSS OR 2X RAFTER OR DOUBLE 2x TOP PLATE, U.N.O. <br />20.WHEN PLYWOOD SIDING IS USED AS AN EXTERIOR OR INTERIOR WALL <br />COVERING, PROVIDE SOLID BLOCKING AT ANY HORIZONTAL JOINTS <br />BETWEEN SOLE PLATE AND ANY TOP PLATE. "Z" BAR METAL SHALL BE <br />USED AT EXTERIOR HORIZONTAL JOINTS. <br />21.INSTALL FIREBLOCKS TO CUT OFF ALL HORIZONTAL AND VERTICAL <br />DRAFT OPENINGS BETWEEN TWO STORIES AND ROOF ATTIC SPACES. <br />FIREBLOCKS SHALL BE OF 2 INCH NOMINAL THICKNESS. LOCATION OF <br />FIREBLOCKS SHALL INCLUDE: <br />A.STUD WALLS AT FURRED SOFFITS, CEILING AND FLOOR LEVELS. <br />B.AROUND TOP, BOTTOM, SIDES AND ENDS OF SLIDING POCKET DOORS <br />C.BETWEEN STAIR STRINGERS AT TOP AND BOTTOM OF RUN AND <br />BETWEEN STUDS IN A WALL PARALLEL AND ADJOINING RUN OF STAIRS. <br />22.FASTENING OF MULTIPLE MEMBERS: <br />DOUBLE & TRIPLE JOISTS; <br />16d NAILS AT 12" O.C STAGGERED (BOTH SIDES FOR TRIPLES). <br />FOUR OR MORE JOISTS; <br />1/2" DIA. M.B's AT 18" O.C STAGGERED. <br />4X OR LARGER BEAMS; <br />1/2" DIA. M.B's AT 12" O.C STAGGERED. <br />23.ALL ROUGH OR RESAWN BEAMS ARE TO BE FREE OF GRADING STAMP <br />LABELS AND FREE OF HEART CENTER (FOHC). <br />24.ALL HANGING 2X JOISTS SHALL UTILIZE SIMPSON "LUS" HANGERS, U.N.O. <br />AND SIMPSON "IUS" FOR I-JOISTS, U.N.O. <br />25.ALL BEARING WALLS ON A WOOD FLOOR ARE TO BE SUPPORTED WITH <br />DOUBLE JOISTS OR SOLID BLOCKING, UNLESS NOTED OTHERWISE. <br />26.ALL BEAMS TO BE SUPPORTED WITH FULL BEARING STUDS OR POSTS, <br />U.N.O. <br />27.ROOF SHEATHING IS TO CONTINUE UNDER "CALIFORNIA FRAMING", TYP. <br />28.APPLY SHEAR WALL PLYWOOD PRIOR TO ALL BOX-OUTS, FUR-OUTS, <br />SOFFITS OR ANY OTHER FRAMING THAT MAY INTERRUPT CONTINUITY OF <br />PLYWOOD. <br />29.PROVIDE FURRING AS NEEDED TO ALIGN NON-SHEAR WALLS WITH <br />SHEAR WALLS. <br />30.PROVIDE 4X OR DOUBLE 2X MEMBERS UNDER SOLE PLATE NAILING LESS <br />THAN 4 in. O.C., U.N.O. <br />31.DOUBLE TOP PLATES w/MIN. 48 in. LAP SPLICES TO BE PROVIDED w/MIN. <br />(12) 16d COMMON NAILS PER TOP PLATE SPLICE U.N.O. PER PLAN. <br />SDPWS-2015/CBC 2022 <br />MATERIAL 8 FRM'G <br />SIZE EDGE <br />NAILING 1,4 <br />FIELD <br />16D <br />SILL <br />LAG5 <br />TRANSFER <br />-- <br />A.B.'S <br />9 <br />5/8"VALUE <br />B 3/8" APA <br />SHEARWALL SCHEDULE <br />SINKER <br />WINDSEISMIC <br />CONFORMING TO ANSI/AF&PA <br />FRAMING <br />CLIP <br />LTP4/A35 <br />3/8" APA 8d 6"12"4"12"--42"220 plf--307 plf24" <br />SILL <br />PLATE <br />2X4 <br />MIN. <br />FOOTNOTES: <br />1.ALL NAILS TO BE COMMON NAILS. <br />2.SIMPSON LPT4 FRAMING ANCHOR MAY BE SUBSTITUTED AT FLAT CONDITIONS. <br />3.ALL STUDS, SILL PLATES AND BLOCKING TO BE 3X FRAMING. <br />4.SOLID BLOCKING SHALL BE PROVIDED AT ALL EDGES AND HORIZONTAL JOINTS. <br />5.SIMPSON STRONG TIE 1/4" SDS X 6" LONG LAG SCREWS. <br />6.PLYWOOD APPLIED TO BOTH SIDES SHALL BE OFFSET OR FRAMING SHALL BE 3X AND <br />NAILS ON EACH SIDE SHALL BE STAGGERED. <br />7.3X @ PANEL JOINTS; 2X FRMG AT TOP PLATES MAY BE USED PROVIDED FULL NAILING <br />WIDTH IS AVAILABLE TO ONE PIECE OF SHT'G; STAGGER NAILS 1/2" & SHT'G. ONE SIDE <br />ONLY. <br />8.SHEETS SHALL NOT BE LESS THAN 4FT BY 8FT, EXCEPT AT BOUNDARIES AND CHANGES <br />WHERE SHEET SHALL BE 24" MINIMUM. <br />9.SQUARE PLATE WASHERS SHALL BE USED WITH ALL ANCHOR BOLTS. <br />5 8" A.B. - 3" X 3" X 0.229" <br />3 4" A.B. - 3" X 3" X 0.229" <br />10.USE 4-1/2" SQ. X .229" AT 2X6 WALLS. <br />11.3X MUDSILL PLATES <br />3X MIN. <br />STAGG'D <br />2X4 BLK. W/ <br />16d @ 4" OC <br />SOLID RIM <br />OR BLK'G <br />SOLE PLATE CONNECTION TO FRAMING BELOW (1) <br />STD. <br />3XDESCRIPTION <br />A <br />RATED <br />RATED 8d 4"12"3"12"--36"320 plf--447 plf16"2X4 <br />CAP. <br />VALUE <br />CAP. <br />C 3/8" APA <br />RATED 8d 3"12"3"8"--24"410 plfYES 575 plf12"2X4 <br />7 <br />STAGG. <br />D 3/8" APA <br />RATED 8d 2"12"2"6"--16"530 plfYES 742 plf10"2X4 <br />7 <br />STAGG. <br />E 15/32" APA <br />RATED 10d 2"12"4"--12"770 plfYES 770 plf10"2X4 <br />7 -- <br />F 15/32" <br />STRUC. 1 10d 2"12"4"--12"870 plfYES 870 plf8"2X47-- <br />WD. PANEL <br />SPECIAL INSPECTION <br />B. HIGH-STRENGTH AND ANCHOR BOLTS <br />C. STEEL MOMENT FRAME CONNECTIONS <br />A. FIELD WELDING <br />D. EPOXY ANCHORS <br />(Continuous) <br />(Continuous) <br />E. STRUCTURAL MASONRY (AS NOTED) <br />(Continuous) <br />(Continuous) <br />(Sect. 1704.5.1.3) <br />F. STRUCTURAL PLYWOOD (<=4" O.C.)(Periodic) <br />G. CONCRETE (OVER 2500 psi)(Continuous) <br />H. POST-TENSION (WHEN OCCURS)(Continuous) <br />I. CAST-IN-PLACE CAISSONS (Continuous) <br />J. SOILS COMPLIANCE (Per Soils Report) <br />EXPOSURE <br />REQUIREMENTS FOR CONCRETE BY EXPOSURE CLASS <br />(ACI 318-19, Table 19.3.2.1) <br />CLASS <br />MAX. <br />W/C <br />MIN. F'c <br />(PSI) <br />ADDITIONAL REQUIREMENTS <br />AIR CONTENT LIMITS ON CEMENT. MAT'L. <br />EXPOSURE <br />CLASS <br />MAX. <br />W/C <br />MIN. F'c <br />(PSI) <br />CEMENTITIOUS MATERIAL TYPE <br />ASTM C150 <br />S0 N/A 2,500 <br />S1 0.50 4,000 <br />S2 0.45 4,500 <br />S3 <br />0.45 4,500 <br />ASTM C595 ASTM C1157 <br />CALCIUM <br />CHLORIDE <br />------------ <br />II <br />V <br />V+POZZOLAN <br />or SLAG <br />TYPE WITH (MS) <br />DESIGNATION <br />TYPE WITH (HS) <br />DESIGNATION <br />TYPES WITH (HS) <br />DESIGNATION + POZ <br />MS <br />HS <br />HS+POZZOLAN <br />or SLAG <br />--- <br />NOT <br />PERMITTED <br />NOT <br />PERMITTED <br />EXPOSURE <br />CLASS <br />MAX. <br />W/C <br />MIN. F'c <br />(PSI) <br />W0 N/A 2,500 <br />W1 N/A 2,500 <br />NONE <br />26.4.2.2(d) <br />EXPOSURE <br />CLASS <br />MAX. <br />W/C <br />MIN. F'c <br />(PSI) <br />MAX. CHLORIDE ION CONTENT % BY WT. <br />REINFORCED CONC. <br />C0 N/A 2,500 <br />C1 N/A 2,500 <br />C2 0.40 5,000 <br />RELATED <br />PROVISIONS <br />1.00 NONE <br />0.30 <br />0.15 <br />--- <br />CONCRETE <br />COVER <br />PRESTRESSED CONC. <br />0.06 <br />0.06 <br />0.06 <br />ADDITIONAL REQUIREMENTS <br />1,2 <br />4 <br />5,6 <br />6 <br />7 <br />7 5 <br />9,10 <br />1,2 <br />1,2 <br />1,2 <br />FREEZING/THAWING <br />SULFATE <br />IN CONTACT WITH WATER <br />CORROSION PROTECTION OF REINFORCEMENT <br />NOTES: <br />1.THE w/cm IS BASED ON ALL CEMENTITIOUS AND SUPPLEMENTARY CEMENTITIOUS MAT. IN THE <br />CONCRETE MIXTURE. <br />2.THE MAXIMUM w/cm LIMITS DO NOT APPLY TO LIGHTWEIGHT CONCRETE. <br />3.FOR PLAIN CONCRETE, THE MAXIMUM w/cm SHALL BE 0.45 AND THE MINIMUM F'c SHALL BE 4,500 PSI. <br />4.ALTERNATIVE COMBINATIONS OF CEMENTITIOUS MAT. TO THOSE LISTED ARE PERMITTED FOR ALL <br />SULFATE EXPOSURE CLASSES WHEN TESTED FOR SULFATE RESISTANCE AND MEETING THE CRITERIA <br />IN 26.4.2.2(c). <br />5.FOR SEAWATER EXPOSURE, OTHER TYPES OF PORTLAND CEMENTS WITH TRICALCIUM ALUMINATE <br />(C3A) CONTENTS UP TO 10 PERCENT ARE PERMITTED IF THE w/cm DOES NOT EXCEED 0.40. <br />6.OTHER AVAILABLE TYPES OF CEMENT SUCH AS TYPE I OR TYPE III ARE PERMITTED IN EXPOSURE <br />CLASSES S1 OR S2 IF THE C3A CONTENTS ARE LESS THAN 8 PERCENT FOR EXPOSURE CLASS S1 OR <br />LESS THAN 5 PERCENT FOR EXPOSURE CLASS S2. <br />7.THE AMOUNT OF THE SPECIFIC SOURCE OF THE POZZOLAN OR SLAG CEMENT TO BE USED SHALL BE <br />AT LEAST THE AMOUNT THAT HAS BEEN DETERMINED BY SERVICE RECORD TO IMPROVE SULFATE <br />RESISTANCE WHEN USED IN CONCRETE CONTAINING TYPE V CEMENT. ALTERNATIVELY, THE AMOUNT <br />OF THE SPECIFIC SOURCE OF THE POZZOLAN OR SLAG CEMENT TO BE USED SHALL BE AT LEAST THE <br />AMOUNT TESTED IN ACCORDANCE WITH ASTM C1012 AND MEETING THE CRITERIA IN 26.4.2.2(c). <br />8.IF TYPE V CEMENT IS USED AS THE SOLE CEMENTITIOUS MAT., THE OPTIONAL SULFATE RESISTANCE <br />REQUIREMENT OF 0.040 PERCENT MAXIMUM EXPANSION IN ASTM C150 SHALL BE SPECIFIED. <br />9.THE MASS OF SUPPLEMENTARY CEMENTITIOUS MAT. USED IN DETERMINING THE CHLORIDE CONTENT <br />SHALL NOT EXCEED THE MASS OF THE PORTLAND CEMENT. <br />10.CRITERIA FOR DETERMINATION OF CHLORIDE CONTENT ATRE IN 26.4.2.2. <br />11.CONCRETE COVER SHALL BE IN ACCORDANCE WITH 20.5. <br />3 3 <br />W2 0.50 4,000 26.4.2.2(d) <br />OR SLAG <br />OPT. <br />1 <br />0.40 5,000OPT. <br />2 V 8 TYPE WITH (HS) <br />DESIGNATION HS <br />NOT <br />PERMITTED <br />11 <br />FLAT BLOCKING TO TRUSS AND WEB FILLER, FACE NAIL 16d COMMON @ 6" O.C. <br />2. CEILING JOIST TO TOP PLATE, TOENAIL EACH END 3-8d <br />3. CEILING JOIST LAPS (NON-PARALLEL CONDITION), FACE NAIL 3-16d <br />4. CEILING JOIST ATTACHED TO PARALLEL RAFTER, FACE NAIL TABLE 2308.7.3.1 <br />5. COLLAR TIE TO RAFTER, FACE NAIL EACH RAFTER 3-10d <br />6. RAFTER/ROOF TRUSS TO PLATE, 2 TOENAILS & 1 TOENAIL PER SIDE 3-10d <br />7. RAFTER TO RIDGE/HIP/VALLEY, TOE NAIL 3-10d <br />RAFTER TO RIDGE/HIP/VALLEY, END NAIL 2-16d <br />8. STUD TO STUD (NON-BRACED WALLS), FACE NAIL 16d COMMON @ 24" O.C. <br />16d BOX @ 16" O.C. <br />9. STUDS AT CORNERS (BRACED WALLS), FACE NAIL 16d COMMON @ 16" O.C. <br />16d BOX @ 12" O.C. <br />10. BUILT-UP HEADER WITH 1/2" SPACER FACE NAIL 16d COMMON @ 16" O.C. <br />16d BOX @ 12" O.C. <br />4-8d <br />12. TOP PLATE TO TOP PLATE, FACE NAIL 16d COMMON AT 16" O.C. <br />10d BOX @ 12" O.C. <br />13. DOUBLE TOP PLATE SPLICE, FACE NAIL EACH SIDE 8-16d <br />14. BOTTOM PLATE TO RIM (NON-BRACED WALLS) FACE NAIL 16d COMMON AT 16" O.C. <br />16d BOX @ 12" O.C. <br />15. BOTTOM PLATE TO RIM (BRACED WALLS), FACE NAIL 2-16d <br />16. TOP/BOTTOM PLATE TO STUD, TOENAIL 4-8d <br />TOP/BOTTOM PLATE TO STUD, END NAIL 2-16d <br />17. TOP PLATE LAPS AT CORNERS/INTERSECTIONS, FACE NAIL 2-16d <br />18. 1" BRACE TO EACH STUD AND PLATE, FACE NAIL 2-8d <br />19. 1X6 SHEATHING TO BEARING, FACE NAIL 2-8d <br />20. 1X8 SHEATHING TO BEARING, FACE NAIL 3-8d <br />21. JOIST TO SILL/TOP PLATE/GIRDER, TOE NAIL 3-8d <br />22. RIM/BAND JOIST OR BLK'G TO SILL/TOP PLATE, TOE NAIL 8d COMMON @ 6" O.C. <br />8d BOX @ 4" O.C. <br />23. 1X6 SUBFLOOR TO EACH JOIST, FACE NAIL 2-8d <br />24. 2" SUBFLOOR TO JOIST OR GIRDER, FACE NAIL 2-16d <br />25. 2" PLANKS 2-16d AT EACH BEARING <br />26. BAND/RIM JOIST TO JOIST, END NAIL 3-16d <br />27. BUILT-UP GIRDERS AND BEAMS FACE NAIL 20d COMMON @ 32" O.C. <br />28. LEDGER STRIP SUPPORTING JOISTS, FACE NAIL 3-16d <br />29. BRIDGING TO JOIST, TOE NAIL 2-8d <br />11. CONTINUOUS HEADER TO STUD, TOE NAIL <br />(CBC 2022 TABLE 2304.10.2) <br />BLOCKING BETWEEN RAFTER/TRUSS NOT AT T.P., EA. END, TOENAIL 2-8d <br />1. RAFTER/JOIST BLOCKING TO TOP PLATE, TOENAIL 3-8d <br />2-20d AT ENDS & SPLICE <br />1.THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL <br />VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING <br />STARTING ANY WORK. THE ENGINEER ( DONG ENG. ) SHALL BE NOTIFIED <br />OF ANY AND ALL DISCREPANCIES. <br />2.DIMENSIONING SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON <br />DRAWINGS. TYPICAL DETAILS AND GENERAL NOTES ARE MINIMUM <br />REQUIREMENTS TO BE USED WHEN CONDITIONS ARE NOT SHOWN <br />OTHERWISE. <br />3.NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER <br />GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE <br />SHOWN CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON <br />PROJECT. <br />4.ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE <br />2022 EDITION OF THE CALIFORNIA BUILDING CODE (CBC), AND ANY <br />OTHER REGULATING AGENCIES WHICH HAVE AUTHORITY OVER ANY <br />PORTION OF THE WORK, INCLUDING THE STATE OF CALIFORNIA DIVISION <br />OF INDUSTRIAL SAFETY, AND THOSE CODES AND STANDARDS LISTED IN <br />THESE NOTES AND SPECIFICATIONS. <br />5.APPROVAL BY THE INSPECTOR DOES NOT CONSTITUTE AUTHORITY TO <br />DEVIATE FROM THE PLANS AND/OR SPECIFICATIONS. ANY DESIGN <br />WHICH FAILS TO BE CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO <br />THE ENGINEER (DONG ENG.) FOR INTERPRETATION OR CLARIFICATION. <br />6.SEE ARCHITECTURAL, ELECTRICAL AND MECHANICAL DRAWINGS FOR <br />PITS, TRENCHES, ROOF OPENINGS, DEPRESSIONS ETC. NOT SHOWN ON <br />STRUCTURAL DRAWINGS. <br />7.VIBRATION EFFECTS OF MECHANICAL EQUIPMENT HAVE NOT BEEN <br />CONSIDERED BY ENGINEER. <br />8.THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, <br />TEMPORARY SUPPORTS, ETC. IS SOLE RESPONSIBILITY OF THE <br />CONTRACTOR, AND HAS NOT BEEN CONSIDERED BY THE ENGINEER <br />(DONG ENG.). THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF <br />THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, <br />ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. HE/SHE SHALL <br />PROVIDE THE NECESSARY BRACING TO PROVIDE STABILITY PRIOR TO <br />THE APPLICATION OF THE AFOREMENTIONED MATERIALS. STRUCTURAL <br />OBSERVATION JOB SITE VISITS BY THE ENGINEER SHALL NOT INCLUDE <br />INSPECTION OF THE ABOVE ITEMS. <br />9.CONTRACTOR SHALL INVESTIGATE SITE DURING CLEARING AND <br />EARTHWORK OPERATIONS FOR FILLED EXCAVATIONS OR BURIED <br />STRUCTURES SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC. <br />IF ANY SUCH STRUCTURES ARE FOUND, THE ENGINEER (DONG ENG.) <br />AND THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY. <br />10.CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON <br />FRAMED FLOORS OR ROOF. LOAD SHALL NOT EXCEED THE DESIGN LIVE <br />LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/OR <br />BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH. <br />11.CONSTRUCTION DOCUMENTS IDENTIFIED AS "BID SET" ON ANY OR ALL <br />SHEETS MAY BE SUBJECT TO REVIEW. THIS REVIEW MAY RESULT IN <br />CHANGES WHICH MAY BE MADE TO THE PLANS PRIOR TO THE ISSUANCE <br />OF THE FINAL CONSTRUCTION SET WHICH WILL CONTAIN NO "BID SET" <br />DESIGNATIONS. CONSTRUCTION DOCUMENTS IDENTIFIED AS "BID SET" <br />ARE NOT CONSTRUED AS BEING THE COMPLETED OR FINAL DRAWINGS <br />AND THEY SHOULD NOT IN ANY WAY BE USED AS SUCH. <br />12.ALL GUARD AND HANDRAILS SHALL BE DESIGNED TO WITHSTAND A <br />POINT LOAD OF 200 POUNDS APPLIED IN ANY DIRECTION AND AT ANY <br />POINT TO TOP RAIL. A 50 PLF LOAD IS REQUIRED AT 3-STORY AND <br />MULTI-FAMILY PROJECTS. IF OCCUPANT LOAD IS LESS THAN 50, A 20 PLF <br />LOAD MAY BE USED. <br />13.THESE PLANS ARE INTENDED SOLELY FOR THE USE OF THE OWNER FOR <br />CONSTRUCTION AND ARE EXPRESSLY NOT INTENDED FOR USE IN <br />MARKETING. EXTERIOR ELEVATIONS AND OTHER DETAILS ON THESE <br />PLANS ARE ONLY A REPRESENTATION AND MAY VARY SIGNIFICANTLY <br />FROM THE ACTUAL CONSTRUCTION. <br />14.SLAB-ON-GRADE REQUIREMENTS TO BE PER THE SOIL ENGINEERS <br />RECOMMENDATIONS SOLELY, U.N.O. THE SLAB-ON-GRADE IS A <br />NON-STRUCTURAL ITEM AND THEREFORE HAS NOT BEEN DESIGNED BY <br />THE STRUCTURAL ENGINEER, UNLESS NOTED OTHERWISE. <br />15.IN THE EVENT OF CONFLICT BETWEEN THE ARCHITECTURAL GENERAL <br />NOTES AND THE STRUCTURAL GENERAL NOTES (SHT S.0), THE MORE <br />STRINGENT REQUIREMENT SHALL GOVERN. <br />1.ALL REINFORCING SHALL BE ASTM A-615 GRADE 40 FOR #4 BARS AND <br />SMALLER. ALL REINFORCING SHALL BE ASTM A-615 GRADE 60 FOR #5 <br />BARS AND LARGER. WELDED WIRE FABRIC TO BE ASTM A-185, LAP 1-1/2 <br />SPACES, 9" MIN. FOR STRUCTURAL SLABS ALL REINFORCING #5 AND <br />LARGER TO BE ASTM A-615 GRADE 60 <br />2.ALL BARS SHALL BE DEFORMED AS PER ASTM A615 / A615M. <br />3.ALL BARS SHALL BE CLEAN OF LOOSE FLAKY RUST, GREASE OR OR <br />OTHER MATERIALS LIKELY TO IMPAIR BOND. <br />4.ALL BENDS SHALL BE MADE COLD. <br />5.SPLICING OF #3-#6 BARS SHALL HAVE A MIN. LAPPING OF 30 DIA. OR 2'-0" <br />MIN. IN ALL CONTINUOUS REINFORCEMENT OF FOOTINGS AND <br />CONCRETE WALLS, EXCEPT AS NOTED ON PLANS. MASONRY <br />REINFORCEMENT SHALL HAVE LAPPINGS OF 40 DIA. FOR GRADE 40 AND <br />48 DIA. FOR GRADE 60 OR 2'-0" MIN., U.N.O. <br />6.ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED <br />BEFORE POURING CONCRETE. <br />7.CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AT LEAST <br />EQUAL TO THE DIAMETER OF THE BARS. COVER SHALL BE AS FOLLOW: <br />1.SPECIAL INSPECTION IS REQUIRED PER CBC SECTION <br />109, 1704 & 1705 FOR THE FOLLOWING CONDITIONS: <br />1.ALL CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE <br />CALIFORNIA CRC CODE. <br />2.CONCRETE SHALL CONFORM TO "EXPOSURE CLASS" REQUIREMENTS OF <br />ACI 318-19 REFER TO SOILS REPORT FOR SOIL CONDITIONS. <br />3.ALL CEMENT SHALL CONFORM TO ASTM C-150, C-595 OR C-1157. USE <br />CEMENT TYPE ................................................ TYPE II <br />4.FINE AND COARSE AGGREGATE SHALL CONFORM TO ASTM C-33 FOR <br />STANDARD WEIGHT CONCRETE AND ASTM C-330 FOR LIGHTWEIGHT <br />CONCRETE. <br />5.CONCRETE FOR SLAB-ON-GRADE SHALL HAVE A MAX. SLUMP OF 5" PER <br />ASTM C-143 AND MAX. SLUMP OF 4" FOR FOOTINGS AND GRADE BEAMS, <br />U.N.O. READY-MIX CONCRETE SHALL BE MIXED AND DELIVERED PER ASTM <br />C-94. <br />6.DRYPACK SHALL BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT <br />MORE THAN THREE PARTS SAND. <br />7.ANCHOR BOLTS, HOLDOWN BOLTS, DOWELS, INSERTS, ETC. SHALL BE <br />SECURED INTO PLACE AND INSPECTED PRIOR TO POURING CONCRETE. <br />8.CONCRETE SHALL BE CURED BY KEEPING CONTINUOUSLY WET FOR <br />10-DAYS OR BY AN APPROVED CURING COMPOUND. <br />9.REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING <br />DRAWINGS FOR MISCELLANEOUS ITEMS TO BE CAST INTO CONCRETE AND <br />FLOOR STEPS, DEPRESSIONS, PITS, CURBS, ETC. <br />10.SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF EXPANSION JOINTS, <br />A/C PADS, SCORING, ETC. FOR CONCRETE WALKS AND SLABS. <br />11.ALL STRUCTURAL CONCRETE ...............................F'c = 3,000 PSI <br />ALL SLAB-ON-GRADE ............................................... F'c = 3,000 PSI <br />ALL CONTINUOUS FOOTINGS AND PADS ............. F'c = 3,000 PSI <br />ALL CONCRETE SHALL REACH MINIMUM COMPRESSIVE STRENGTH <br />28 - DAYS (MIN. W/C RATIO=0.5). <br />12.ALL CONCRETE WITH F'c GREATER THAN 3,000 PSI SHALL HAVE SPECIAL <br />INSPECTION PER SECTION 1704 & 1707 OF THE CALIFORNIA BUILDING CODE <br />(CBC 2022) UNLESS NOTED OTHERWISE. <br />F0 N/A 2,500 N/A N/A <br />F1 0.55 3,500 ACI 318-19 TABLE 19.3.3.3 N/A <br />F2 0.45 4,500 ACI 318-19 TABLE 19.3.3.3 N/A <br />F3 0.40 5,000 ACI 318-19 TABLE 19.3.3.3 ACI 318-19 TABLE 26.4.2.2(b) <br />1.ALL STRUCTURAL SAWN LUMBER SHALL BE GRADED BY ONE OF THE <br />FOLLOWING: W.C.L.I.B., W.W.P.A., N.L.G.A, or PS 20. <br />2.ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE <br />TREATED DOUGLAS FIR (PTDF), U.N.O <br />3.HOLES FOR BOLTS SHALL BE BORED WITH A BIT 1/32" TO 1/16" LARGER <br />THAN THE NOMINAL BOLT DIAMETER. <br />4.ALL BOLTS SHALL BE RE-TIGHTENED PRIOR TO APPLICATION OF FINISH <br />MATERIALS (PLYWOOD, PLASTER, DRYWALL, INSULATION, ETC.) <br />5.STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ETC. UNLESS <br />SPECIFICALLY NOTED OR DETAILED. CONTACT ENGINEER IF NOT <br />SHOWN. <br />6.2X SOLID BLOCKING SHALL BE PLACED BETWEEN JOISTS AND/OR <br />RAFTERS AT ALL SUPPORTS, EXCEPT WHEN LEDGERED (U.N.O.) <br />7.CROSS-BRIDGING SHALL BE PROVIDED AT 8'-0" O.C. MAX. FOR ALL 2X <br />FLOOR JOISTS OVER 10" IN DEPTH AND ALL 2X ROOF RAFTERS OVER 10" <br />DEPTH. USE SOLID BLOCKING OR AN APPROVED METAL TYPE BRIDGING. <br />8.ALL STRUCTURAL PLYWOOD SHALL BE A.P.A. RATED SHEATHING (OR <br />OSB) EXPOSURE 1 OR EXTERIOR UNLESS NOTED OTHERWISE AND <br />CONFORM TO DOC PS1 OR PS2. EACH SHEET SHALL BE IDENTIFIED BY <br />GRADE MARK OF D.F.P.A OR A.P.A. <br />9.ALL BOLTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS <br />UNDER HEAD AND NUT UNLESS NOTED OTHERWISE. <br />10.ALL METAL ANCHORS, FASTENERS AND CONNECTORS ETC. SHALL BE <br />FROM "SIMPSON STRONG-TIE" (TM). SUBSTITUTIONS MUST BE ICC-ESR <br />PRODUCTS AND PRE-APPROVED IN WRITING BY ENGINEER (DONG ENG.). <br />11.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LARCH (OR BTR.), 19% <br />MAX. MOISTURE CONTENT, OF THE FOLLOWING GRADES, U.N.O.: <br />2X4 STUDS (UP TO 10')..................... "STANDARD" OR BETTER <br />2X4 STUDS (OVER 10')......................NO.2 OR BETTER <br />2X PLATES & 3X PLATES.................. "CONSTRUCTION GRADE" OR BETTER <br />2X6 STUDS......................................... NO.2 <br />2X JOIST............................................. NO.2 <br />BEAMS AND STRINGERS <br />4X10 AND SMALLER.......................... NO.2 <br />4X12 AND LARGER........................... NO.1 <br />6X AND 8X........................................... NO.1 <br />4x POST/TIMBERS AND LARGER .... NO.1 <br />ROOF PLANKING AND DECKING...... COM.DEX. <br />BOARD SHTG. AND STRIPPING........ SUITABLE FOR INTENDED USE. <br />32.TOP PLATE BREAKS AND SPLICES SHALL OCCUR OVER A STUD OR POST. <br />33.PROVIDE SOLID BLOCKING BETWEEN PERPENDICULAR JOIST AT BEARING AND <br />AT SHEAR WALLS. <br />34.ALL EXPOSED BEAMS AND HEAVY TIMBER RECOMMENDED TO BE FREE OF <br />HEART CENTER (FOHC). <br />35.ALL ISOLATED POSTS AND BEAMS TO HAVE SIMPSON ABU's, PB's AND/ OR BC's <br />MINIMUM, UNLESS NOTED OTHERWISE. <br />36.ALL SIMPSON HDU, HTT, HDQ, HHDQ, AND CB HOLDOWNS TO BE FASTENED TO <br />4x4 POST MIN., U.N.O. <br />37. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS ARE TO BE SECURED <br />WITH MIN. 5/8" DIA. x 12" ANCHOR BOLTS AT 72 in. O.C., U.N.O. MIN. (2) BOLTS PER <br />PIECE WITH (1) BOLT LOCATED NOT MORE THAT 12" OR LESS THAN 7 BOLT DIA. <br />FROM EACH END AND/OR SPLICE OF THE PIECE. <br />38.ALL INTERIOR NON-SHEAR WALLS TO BE SECURED WITH ICC-ESR APPROVED <br />SHOT PINS WITH CADMIUM WASHERS AT 32" O.C. PER MANUF. SPECS., U.N.O. <br />PROVIDE ANCHOR 6" FROM ALL CORNERS AND SPLICES. <br />39.ALL CONVENTIONAL FRAME PORTIONS OF STRUCTURE ARE TO BE <br />CONSTRUCTED PER CRC. <br />40.ALL SHOP DRAWINGS ARE TO BE REVIEWED BY THE GENERAL CONTRACTOR <br />AND THE ARCHITECT PRIOR TO SUBMITTAL FOR ENGINEER ( DONG ENG. ) <br />REVIEW. <br />41.PROVIDE MIN. 2X6 RAFTERS AT 24" O.C. WITH MAX. SPAN OF 6'-0"± BRACED TO <br />FRAMING BELOW AT OVERSTACK ("CALIFORNIA") FRAMING. <br />42.PROVIDE DOUBLE 2X SOLE PLATES WITH PROGRESSIVE SOLE PLATE NAILING AS <br />SPECIFIED ON THE PLANS AT BOTH PLATES WHERE 1 1/2" LIGHT WEIGHT <br />CONCRETE IS USED AT THE FLOOR. <br />43.WHERE BOTH TOP PLATES ARE BROKEN, SPLICE WITH ST6224 MIN. U.N.O. <br />44.COMMON NAILS SHALL BE USED FOR ALL SHEATHING AND TOP PLATE SPLICES. <br />BOX NAILS MAY BE USED AT SOLE PLATE NAILING. ALL HARDWARE SHALL BE <br />INSTALLED WITH NAILS PER THE MANUFACTURERS SPECIFICATIONS AND <br />RECOMMENDATIONS. <br />45.ALL HEADERS SHALL BE FRAMED WITH A MINIMUM OF (1) 2X4 TRIMMER AND (1) <br />2X4 KING STUD AT EACH END, U.N.O. <br />46.AT ANY SOLE PLATES OR TOP PLATES CUT FOR PIPES, PROVIDE A .058" THICK <br />(16 1 GA.) AND 1 " WIDE PLATE ACROSS EACH SIDE OF OPENING WITH NOT LESS <br />THAN (6) 2 16d NAILS. <br />47.PROVIDE SOIL BLOCKING AT SOFFIT CEILINGS. <br />48.SHEAR SHALL BE CONTINUOUS FROM BOTTOM PLATES TO TOP PLATES., U.N.O. <br />49.STAIR STRINGER SHALL BE 2x12 DF#1 AT MAX. 16" O.C., U.N.O. <br />50.A SINGLE TOP PLATE IS PERMITTED PROVIDED THE PLATE IS ADEQUATELY TIED <br />AT JOINTS, CORNERS AND INTERSECTING WALLS BY AT LEAST THE EQUIVALENT <br />OF 3 IN, X 6 IN. X .036 IN. THICK GALVANIZED STEEL PLATE THAT IS NAILED TO <br />EACH WALL OR SEGMENT OF WALL BY (6) 8d NAILS OR EQUIVALENT. <br />51.FASTENERS IN CONTACT WITH PRESSURE TREATED OR PRESERVATIVE <br />TREATED LUMBER SHALL BE HOT DIPPED ZINC COATED GALVANIZED STEEL, <br />STAINLESS STEEL, SILICON BRONZE OR COPPER. EXCEPTION: PLAIN CARBON <br />STEEL FASTENERS IN SBX/DOT AND ZINC BORATE PRESERVATIVE-TREATED <br />WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED. <br />1.ALL SITE PREPARATION, EXCAVATION AND COMPACTION SHALL BE DONE UNDER THE <br />SUPERVISION OF THE SOIL ENGINEER. <br />2.SEPARATE PERMITS SHALL BE OBTAINED FOR ALL FENCES, PLANTERS AND WALLS, AS <br />REQUIRED. <br />3.PROVIDE NON-EXPANSIVE FILL AS REQUIRED TO LEVEL PAD. <br />4.SURFACE WATER WILL DRAIN AWAY FROM BUILDING. DRAINAGE SHALL BE 2% (MIN.) FROM <br />BUILDING TO SWALE LINE. SWALE SHALL DRAIN AT 1% (MIN.) FROM REAR OF BUILDING TO <br />STREET. <br />5.THERE SHALL BE NO UTILITY TRENCH NEAR THE BUILDING FOUNDATION WHICH EXTEND <br />DEEPER THAN A 45 DEGREE LINE PROJECTED DOWN AND AWAY FROM THE BOTTOM <br />OUTSIDE CORNER OF ANY FOOTING. <br />6.SLAB SUBGRADE REQUIREMENTS ARE NOT WITHIN THE SCOPE OF WORK AND/OR LIABILITY <br />OF ENGINEER ( DONG ENG. ). THE SUBGRADE CONFIGURATION SHOWN IN DETAIL 1/SD1 OR <br />THE POST-TENSION DETAILS REFLECT THE GENERAL RECOMMENDATIONS OF THE SOILS <br />ENGINEER, AND/OR THE SITE CONDITIONS. IT IS THE RESPONSIBILITY OF THE OWNER TO <br />REVIEW THE SLAB SUBGRADE CONFIGURATION WITH THE SOILS ENGINEER, AND <br />CONCRETE/FLOORING CONTRACTORS, FOR ADEQUATE MOISTURE PROTECTION. PLEASE <br />REFER TO THE SOILS REPORT FOR ADDITIONAL RECOMMENDATIONS. THE SUBGRADE <br />MOISTURE/VAPOR RETARADER SHALL MEET THE CONFORMANCE OF ASTM E1745 CLASS A or <br />B MATERIAL. <br />7.ALL HOLDOWN ANCHORS, POST BASES AND HOLDOWN BOLTS SHALL BE TIED INTO PLACE <br />PRIOR TO FOUNDATION INSPECTION. <br />8.PLACE 20'-0" REBAR IN FOUNDATION AT SERVICE LOCATIONS. STUB UP REBAR ABOVE THE <br />FLOOR BY ELECTRIC SERVICE METERS. <br />9.FOR THE LOCATION OF CONTROL JOINTS, REFER TO THE FOUNDATION PLAN. (ZIP STRIP OR <br />EQUAL). MINIMUM OF 20'-0" O.C. EACH WAY IS RECOMMENDED. <br />10.DRIVEWAY PAVING SHALL BE 4" PORTLAND CEMENT CONCRETE (5 SACKS MIN.), U.N.O. <br />11.FOR POST-TENSION SLAB, REFER TO APPROVED PLANS PREPARED BY OTHERS (WHEN <br />OCCURS). <br />12.MINIMUM SLAB REINFORCEMENT AND PAD REQUIREMENT SHALL CONFORM TO THE SOILS <br />ENGINEER'S RECOMMENDATIONS, U.N.O.. <br />1.THE DEPICTIONS OF ALL MISCELLANEOUS FABRICATED METAL PRODUCTS SHOWN HEREON <br />ARE NOT INTENDED TO BE USED AS FABRICATION SHOP DRAWINGS. THE METAL FABRICATOR <br />SHALL BE RESPONSIBLE FOR ALL METAL FABRICATION DESIGNS IN ACCORDANCE WITH ALL <br />NATIONAL, STATE AND LOCAL CODES AND POLICIES AS WELL AS THE AMERICAN INSTITUTE <br />OF STEEL CONSTRUCTION (AISC) AND ANY OTHER INDUSTRY STANDARDS. ALL METAL <br />FABRICATION DESIGNS ARE TO BE SUBMITTED TO, AND APPROVED BY, THE LOCAL BUILDING <br />INSPECTION DEPARTMENT RESPONSIBLE FOR THE PROJECT PRIOR TO FABRICATION. ALL <br />DETAILS, DIMENSIONS, ETC., SHOWN HEREON ARE INTENDED TO BE SCHEMATIC AND THE <br />DESIGN IS TO BE VERIFIED WITH ALL AFFECTED FIELD CONDITIONS. SUBCONTRACTORS AND <br />THE REQUIREMENTS OF ALL GOVERNING AGENCIES AND FABRICATION STANDARDS. <br />FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH <br />"SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR <br />BUILDINGS", AISC, CURRENT EDITION. STEEL SHALL CONFORM TO ASTM A-992, U.N.O. <br />2.ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS, USING THE ELECTRIC <br />SHIELDING PROCESS AND CONFORMING TO AWS D1.1 SPECIFICATIONS, E70XX ELECTRODE. <br />3.ALL STRUCTURAL STEEL SHALL BE FABRICATED IN THE SHOP OF A LICENSED FABRICATOR <br />AND SHOP DRAWINGS SHALL BE SUBMITTED TO ENGINEER ( DONG ENG. ), ARCHITECT, <br />GENERAL CONTRACTOR AND OWNER FOR APPROVAL PRIOR TO FABRICATION. AN <br />PROPOSED DEVIATION, ADDITION OR QUESTIONS SHALL BE NOTED CONSPICUOUSLY AND <br />CLEARLY ON THE SHOP DRAWINGS. STEEL FABRICATOR SHALL FIELD VERIFY ALL <br />DIMENSIONS PRIOR TO ERECTION TO PROVIDE FOR A PROPER FIT. <br />4.ALL FIELD WELDING (EXCEPT MINOR AND TACK WELDING) SHALL BE CONTINUOUSLY <br />INSPECTED BY AN APPROVED WELDING INSPECTOR. WELDING AT BRACED & MOMENT <br />FRAMES SHALL HAVE WELDING FILLER METAL WITH CHARPY V-NOTCH (CVN) TOUGHNESS OF <br />20 ft-lb AT 70 deg (E70T-4 IS PROHIBITED). <br />5.USE 3/4" ROUND MACHINE BOLTS, 13/16" ROUND HOLES, FOR ALL CONNECTIONS, UNLESS <br />OTHERWISE SHOWN. ALL BOLTS SHALL CONFORM TO ASTM A-307 FOR UNFINISHED BOLTS, <br />EXCEPT WHERE SPECIFICALLY NOTED AS "HIGH STRENGTH" BOLTS WHICH SHALL CONFORM <br />TO ASTM A-325 OR ASTM A-490. HI-TENSILE BOLTS SHALL BE THE FRICTION TYPE AND THERE <br />SHALL BE NO PAINT, OIL, LACQUER, OR GALVANIZING BETWEEN THE CONTACT SURFACE. <br />HIGH STRENGTH BOLTS REQUIRE SPECIAL INSPECTION PER CBC SECTIONS 1704 AND 1707. <br />6.ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION. <br />7.PIPE COLUMNS SHALL CONFORM TO ASTM A-53-B (TYPE E OR S). <br />8.TUBE COLUMNS SHALL CONFORM TO ASTM A-501 OR A-500 GRADE B. <br />9.WHERE FINISH IS ATTACHED TO STRUCTURAL STEEL, PROVIDE 1/2"x3" NELSON STUDS AT <br />3'-0" O/C FOR ATTACHMENT OF NAILERS, U.N.O. SEE ARCHITECTURAL DRAWINGS FOR <br />FINISHES. <br />10.NONDESTRUCTIVE TESTING PER 2019 CBC SECTION 1703 ON STEEL MOMENT CONNECTION <br />BETWEEN STEEL BEAM AND STEEL COLUMN, ALL FULL PENETRATION GROOVE WELDS <br />CONTAINED IN JOINTS AND SPLICES SHALL BE TESTED 100 PERCENT EITHER BY <br />ULTRASONIC TESTING OR BY RADIOGRAPHY. <br />23/32" APA RATED STURD-I-FLOOR T&G EXP I WITH MIN. SPAN RATING OF 24" O.C. <br />REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE WITH 10d COMMON <br />NAILS AT 6" O.C. EDGES & BOUNDARIES, 12" O.C. FIELD. <br />USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING <br />ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN <br />ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. <br />AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE <br />USED: GRABBER PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE QUICK <br />DRIVE SCREWS (ICC-ER-1472), MIN 2" LONG @ 6" O.C. B.S., @ 6" O.C. E.S. AND 12" O.C. <br />F.S. <br />15/32" APA RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. REFER TO <br />NER 108 FOR INSTALLATION AND CONDITIONS OF USE WITH 8d COMMON NAILS AT 6" <br />O.C. EDGES & BOUNDARIES, 12" O.C. FIELD.. <br />NOTE: ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE <br />FOLLOWING APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG. <br />1.ALL GLUED LAMINATED MEMBERS SHALL BE MADE OF 1-1/2" DOUGLAS-FIR <br />LARCH (DF)LAMINATIONS, COMBINATION 24F-V4 PER AITC/APA (U.N.O.). <br />2.DESIGN VALUES: Fb=2400 PSI; Fv=240 PSI; E=1.8X106 PSI <br />3.INDUSTRIAL APPEARANCE GRADE PER APA-EWS SHALL BE USED, WITH A <br />MOISTURECONTENT BETWEEN 7 - 14 PERCENT, UNLESS NOTED OTHERWISE. <br />4.FABRICATOR SHALL BE A MEMBER OF AITC AND ALL FABRICATION SHALL BE <br />PERFORMED IN ACCORDANCE WITH AITC-A190.1 & ASTM-3737. LUMBER SHALL <br />BE MARKED WITH AN AITC or APA-EWS GRADE STAMP INDICATING <br />CONFORMANCE WITH ALL APPLICABLE SPECIFICATIONS AND REQUIREMENTS. <br />5.GLUED LAMINATED MEMBERS SHALL BE ACCOMPANIED BY A CERTIFICATE OF <br />INSPECTION. CONTRACTOR SHALL BEAR EXPENSES OF INSPECTION AND TESTS. <br />A CERTIFICATE OF INSPECTION SHALL BE SUBMITTED TO THE BUILDING <br />DEPARTMENT PRIOR TO INSTALLATION. <br />6.ALL GLUED LAMINATED BEAMS WILL HAVE A STANDARD CAMBER BASED ON A <br />RADIUS = 3500, UNLESS NOTED OTHERWISE. <br />7.PARALLAM PSL 2.0E BY I-LEVEL PER ESR-1387 & LARR-25202 <br />f b = 2900 PSI; fv = 290 PSI; E = 2.0x106 PSI <br />TIMBERSTRAND LSL 1.55E BY I-LEVEL PER ESR-1387 & LARR-25202 <br />f b = 2250 PSI; fv = 310 PSI; E = 1.55x106 PSI <br />MICROLAM LVL BY I-LEVEL PER ESR-1387 & LARR-25202 <br />f b = 2600 PSI; fv = 285 PSI; E = 2.0x106 PSI <br />8.ALTERNATE ENGINEERED WOOD PRODUCTS MUST BE APPROVED IN WRITING <br />BY ENGINEER <br />(DONG ENGINEERING) PRIOR TO INSTALLATION. <br />9.PROVIDE MULTIPLE 2x4 SQUASH BLOCKS UNDER BEARING POINT LOAD (POST) <br />(OR MSB) FROM ABOVE TO TOP PLATES BELOW AT FLOOR LEVEL. <br />10.I-LEVEL I-JOISTS PER ICC ESR#1533, RR#25538 <br />LOUISIANA PACIFIC I-JOISTS PER ICC ESR#1130, RR#25176 <br />BOISE CASCADE I-JOISTS PER ICC ESR#1336, RR#24999 <br />ROSEBURG I-JOISTS PER ICC ESR#1251, RR#25439 <br />11.PROVIDE DOUBLE I-JOISTS OR DOUBLE I-JOIST BLOCKS WHEN 16d SOLE PLATE <br />NAILING (SPN) <br />IS LESS THAN 4" O.C. AT SHEAR WALL ABOVE. <br />12.REFER TO I-JOIST MANUFACTURER SPECIFICATION FOR DRILLING OF HOLES <br />THRU I-JOIST WEB. NOTCHING OF I-JOIST FLANGE IS PROHIBITED. <br />NOTES: 1. COMMON NAILS SHALL BE USED (U.N.O.) <br />2. JOIST CAN BE EITHER SAWN LUMBER OR I-JOIST PER PLAN <br />RESTRICTIVE NOTICE <br />DATE REVISIONS <br />SHEET DESCRIPTION <br />PROJECT OWNER <br />PROJECT ADDRESS <br />STAMP <br />NO: <br />REVISIONS <br />THESE DESIGNS, DRAWINGS, AND <br />SPECIFICATIONS ARE THE EXCLUSIVE <br />PROPERTY OF DONG ENGINEERING. <br />THESE DRAWINGS CANNOT BE COPIED, <br />TRANSFERRED, OR REPRODUCED NOR <br />CAN ANY OTHER STRUCTURES BE BUILT <br />FROM THEM WITHOUT WRITTEN CONSENT. <br />SHEET <br />DE#: <br />TEL- 714-617-5979 <br />GARDEN GROVE, CA 92841 <br />7661 GARDEN GROVE BLVD., <br />DONG ENGINEERING, INC. <br />INFO@DONGENGINEERING.COM <br />230520 <br />AD <br />D <br />I <br />T <br />I <br />O <br />N <br />- <br />A <br />D <br />U <br />21 <br />0 <br />2 <br /> <br />N <br />. <br />W <br />R <br />I <br />G <br />H <br />T <br /> <br />S <br />T <br />, <br /> S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />04/09/2024 PLAN CHECK1. <br />S.0 <br />GENERAL NOTES <br />2102 N Wright St & #2 - <br />101117955-566/13/2024