Laserfiche WebLink
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:230520 Calculation Date/Time:2023-11-29T00:12:01-08:00 (Page 12 of 14) <br />Calculation Description:Title 24 Analysis Input File Name:1 STORY ADDITION GARAGE Z8.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2023-11-29   00:12:37 <br />HVAC HEAT PUMPS - HERS VERIFICATION <br />01 02 03 04 05 06 07 08 09 <br />Name Verified Airflow Airflow Target Verified EER/EER2 Verified <br />SEER/SEER2 <br />Verified Refrigerant <br />Charge <br />Verified <br />HSPF/HSPF2 <br />Verified Heating <br />Cap 47 <br />Verified Heating <br />Cap 17 <br />Heat Pump System <br />2-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes <br />VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION <br />01 02 03 04 05 06 07 08 09 10 <br />Name <br />Certified <br />Low-Static <br />VCHP System <br />Airflow to <br />Habitable <br />Rooms <br />Ductless Units <br />in Conditioned <br />Space <br />Wall Mount <br />Thermostat <br />Air Filter Sizing <br />&amp; Pressure <br />Drop Rating <br />Low Leakage <br />Ducts in <br />Conditioned <br />Space <br />Minimum <br />Airflow per <br />RA3.3 and <br />SC3.3.3.4.1 <br />Certified <br />non-continuous <br />Fan <br />Indoor Fan not <br />Running <br />Continuously <br />Heat Pump System 2 Not required Required Required Required Not required Not required Not required Not required Not required <br />HVAC - DISTRIBUTION SYSTEMS <br />01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 <br />Name Type Design Type <br />Duct Ins. <br />R-value <br />Duct <br />Location Surface Area <br />Bypass Duct Duct Leakage HERS <br />Verification Status <br />Verified <br />Existing <br />Condition <br />Existing <br />Distribution <br />system <br />New Ducts <br />25 ftSuppl <br />y <br />Retur <br />n <br />Suppl <br />y <br />Retur <br />n <br />Suppl <br />y <br />Retur <br />n <br />Air <br />Distribution <br />System 1 <br />Unconditio <br />ned attic <br />Non- <br />Verified R-6 R-6 Atti <br />c <br />Atti <br />c n/a n/a No Bypass <br />Duct <br />Existing <br />(not <br />specified) <br />Air <br />Distribution <br />System <br />1-hers-dist <br />Existing No No <br />HVAC - FAN SYSTEMS <br />01 02 03 04 <br />Name Type Fan Power (Watts/CFM)Name <br />HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan <br />423-P010214446A-000-000-0000000-0000 11/29/2023 00:26 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />2102 N Wright St & #2 - <br />101117955-566/13/2024