My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2105 N Poinsettia St - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Poinsettia St
>
2105 N Poinsettia St
>
2105 N Poinsettia St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:01:28 PM
Creation date
6/1/2025 12:01:22 PM
Metadata
Fields
Template:
Plan
Permit Number
20180740
101116349
Full Address
2105 N Poinsettia St
Document Relationships
101116349 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Poinsettia St\2105 N Poinsettia St
20180740 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Poinsettia St\2105 N Poinsettia St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Notes: <br />x Tables are based on strength of the InvisiMount rail and approved roof attachment in the Engineering Summary <br />Letter of this document, in conformance with IBC and referenced standards. <br />x Maximum allowable cantilever is equal to 1/3 of the allowable span. <br />x Wind speeds are ultimate values in mph, as defined in ASCE 7. Wind pressure coefficients are derived from wind <br />tunnel testing in conformance with ASCE 7 Chapter 31. <br />x Tables are valid for mean roof height ≤ 30 ft, gable end width ≤ 40 ft, and ridge length ≤ 60 ft. <br />x Tables apply to any location on the roof, except that PV modules must be set back at least 10 inches from all <br />ridges and roof edges. <br />x User is responsible for verifying the strength of the roof. <br />x User is responsible for verifying the capacity of the module. Module pressures are provided above and are <br />derived from the Wind Tunnel Test Report. The user must confirm that the design capacities of the module are <br />greater than both the uplift and downforce pressured identified. <br />Document #524734 Rev G, Vol. 10 12 SunPower Proprietary <br /> Inputs INVISIMOUNT ALLOWABLE SPANS (IN) <br /> Slope→ 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° <br />Exposure C Speed↓ 4:12 5:12 6:12 7:12 8:12 <br />Ground Snow (psf) 0 135 72 80 80 80 80 <br />Height (ft) 30 140 72 72 72 72 72 <br />Seismic, Ss (g) 3.73 145 64 72 72 72 72 <br /> 150 64 64 64 64 64 <br /> 160 48 48 48 48 48 <br /> 170 48 48 48 48 48 <br /> 180 32 32 32 32 32 <br /> <br />UPLIFT MODULE PRESSURE (PSF) DOWNFORCE MODULE PRESSURE (PSF) <br />Slope → 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° Slope→ 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° <br />Speed↓ 4:12 5:12 6:12 7:12 8:12 Speed↓4:12 5:12 6:12 7:12 8:12 <br />135 -32 -32 -33 -33 -33 135 19 19 19 34 34 <br />140 -35 -35 -35 -35 -35 140 19 19 19 36 36 <br />145 -38 -38 -38 -38 -38 145 19 19 19 39 39 <br />150 -41 -41 -41 -41 -41 150 19 19 19 41 41 <br />160 -47 -47 -47 -47 -47 160 20 20 20 46 46 <br />170 -53 -53 -53 -53 -53 170 23 23 23 52 52 <br />180 -60 -60 -60 -60 -60 180 25 25 25 58 58 <br /> <br /> <br /> <br /> <br /> <br />2105 N <br />St08/28/23
The URL can be used to link to this page
Your browser does not support the video tag.