My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2109 N Poinsettia St - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Poinsettia St
>
2109 N Poinsettia St
>
2109 N Poinsettia St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:01:52 PM
Creation date
6/1/2025 12:01:32 PM
Metadata
Fields
Template:
Plan
Permit Number
20179481
101114901
Full Address
2109 N Poinsettia St
Document Relationships
101114901 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Poinsettia St\2109 N Poinsettia St
20179481 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Poinsettia St\2109 N Poinsettia St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2141 LOS POSITAS COURT <br />(SUIT #C) <br />LIVERMORE,CA 94551 <br />(925) 800 5140 <br />CA LIC: 993467 CLASS:C10 <br />C:\Users\User\Box Sync\1- BLITZ TEMPLATES\ANA (AMERICAN ARRAY) TEMPLATE\signature for plans.JPG <br />Solar Photovoltaic System <br />NEIL ROSALES <br />2109 POINSETTIA ST N <br />SANTA ANA, CA 92706 <br />(714) 510-1110 <br />PV-1 <br />PROJECT INFORMATION VICINITY MAPPLAN SET LEGEND <br />SUB SERVICE PANEL <br />AC DISCONNECT <br />DC DISCONNECT <br />SOLAR LOAD CENTER <br />EV OUTLET <br />SUB <br />AC <br />DC <br />SLC <br />EV <br />JUNCTION BOXJB <br />COMBINER BOXCB <br />ABBREVIATIONS <br />EXTERIOR <br />INTERIOR <br />EXT <br />INT <br />NEW(N) <br />EXISTING(E) <br />ELECTRICAL METALLIC TUBINGEMT <br />RIGID METALLIC TUBINGRMT <br />VOLTAGE OPEN CIRCUITVOC <br />VOLTAGE AT MAX. POWERVMP <br />SHORT CIRCUIT CURRENTISC <br />CURRENT AT MAX. POWERIMP <br />MONITORING METERM <br />NOT TO SCALENTS <br />MAIN SERVICE PANEL MSP <br />DEVICERSRAPID SHUTDOWN <br />PROJECT <br />INFORMATION <br />N <br />2/15/2023 <br />PROJECT INFO <br />21 X 360 W PANASONIC EVERVOLT <br />EVPV360PK <br />ROOF MOUNTED SOLAR <br />PHOTOVOLTAIC MODULES <br />21 X 290 W ENPHASE IQ8PLUS-72-2-US <br />(240V) (SI1-JUN20) <br />SYSTEM SIZE: 6.844 kW AC STC <br />SYSTEM SIZE: 7.560 kW DC CEC <br />ARRAY AREA: 413 SF <br />AHJ: CITY OF FREMONT <br />APN: 519-120-316 <br />VICTOR CHEN <br />473 CRAYCROFT DR <br />FREMONT, CA 94539 <br />DATE: <br />PROJECT <br />SITE <br />PV-1 PROJECT INFORMATION <br />PV-1A SITE PLAN, HOUSE PHOTO <br />PV-2 ROOF PLAN <br />PV-2A ATTACHMENT DETAILS <br />PV-2B RAFTER SECTION DETAILS <br />PV-3 ELECTRICAL LINE DIAGRAM <br />PV-3A ELECTRICAL NOTES <br />PV-4 REQUIRED SIGNAGE <br />OCCUPANCY: R-3 <br />CONSTRUCTION TYPE: VB <br />UNSPRINKLERED <br />AHJ NOTES SHEET INDEXAPPLICABLE CODES <br />MICROINVERTERS HAVE RAPID <br />SHUTDOWN REQUIREMENTS PER <br />NEC 2017 SECTION 690.12 <br />ALL CONDUIT TO RUN ON EXTERIOR <br />OF HOUSE UNLESS OTHERWISE NOTED <br />WITH ENPHASE RAPID SHUTDOWN IS <br />BUILT IN: ENPHASE SYSTEMS <br />INSTALLED INHERENTLY MEET NEC <br />2014 & NEC 2017 RAPID SHUTDOWN <br />REQUIREMENTS. IT'S A FUNCTION OF <br />HOW THEY WORK. WHEN THE AC <br />UTILITY SOURCE IS REMOVED IN ANY <br />WAY-THROUGH AN AC BREAKER, AC <br />DISCONNECT, OR REMOVAL OF THE <br />MAIN METER, FOR EXAMPLE - THE <br />MICROINVERTER PERFORMS ITS <br />RAPID SHUTDOWN FUNCTION. <br />trutone@me.com <br />ALL WORK TO COMPLY WITH <br />THE FOLLOWING CODES: <br />2022 CA BUILDING CODE <br />2022 CA RESIDENTIAL CODE <br />2022 CA MECHANICAL CODE <br />2022 CA ELECTRICAL CODE <br />2022 CA GREEN CODE <br />2022 CA PLUMBING CODE <br />2022 CA ENERGY CODE <br />2022 CA FIRE CODE <br />PER SECTION R314 AND R315 OF CRC 2022, IT'S REQUIRED THAT SMOKE ALARM AND <br />CARBON MONOXIDE DETECTORS ARE RETROFITTED INTO THE EXISTING DWELLING FOR A <br />PERMIT WITH REPAIRS OR ADDITIONS EXCEEDING $1,000. <br />ALL NEW UTILITY CONNECTIONS ARE REQUIRED TO BE INSTALLED BELOW GRADE BY <br />SANTA ANA MUNICOPAL CODE 41-626(b). THERE IS A STANDING EXCEPTION FOR EXISTING <br />ONE AND TWO FAMILY DWELLINGS. THIS EXCEPTION APPLIES ONLY WHEN THE NEW <br />ELECTRICAL SERVICE IS DESIGNATED TO BE FED FROM BELOW GRADE AS WELL AS <br />OVERHEAD. <br />ONLY LISTED COMBINATION OVERHEAD AND UNDERGROUND FEED SERVICE BOXES MAY <br />BE USED TO CONNECT TO AN OVERHEAD UTILITY DROP. THIS EXCEPTION TO AN <br />UNDERGROUND FED SERVICE APPLIES ONLY TO EXISTING SINGLE FAMILY AND TWO <br />FAMILY RESIDENCES. <br />BI-DIRECTIONAL <br />UTILITY METER <br />#222013-579554 <br />PANEL UPGRADE: 200/200 A <br />The scope of the plans is for the installation of the <br />solar photovoltaic system only and the approval is <br />subject to compliance with all applicable city and state <br />codes and regulations regarding construction. The <br />approval of the plans does not constitute any <br />certification of the accuracy, completeness, or building <br />permit status of the existing buildings and structures <br />as shown. <br />Bldg# 101114901 <br />Elec# 20179481 <br />Issued 05/02/23 <br />2109 N Poinsettia St <br />05/03/23
The URL can be used to link to this page
Your browser does not support the video tag.