Laserfiche WebLink
Solar Photovoltaic System <br />NEIL ROSALES <br />2109 POINSETTIA ST N <br />SANTA ANA, CA 92706 <br />(714) 510-1110 <br />2141 LOS POSITAS COURT <br />(SUIT #C) <br />LIVERMORE,CA 94551 <br />(925) 800 5140 <br />CA LIC: 993467 CLASS:C10 <br />C:\Users\User\Box Sync\1- BLITZ TEMPLATES\ANA (AMERICAN ARRAY) TEMPLATE\signature for plans.JPG <br />PV-3A <br />DATE: <br />ELECTRICAL NOTES <br />ELECTRICAL NOTES <br />2/15/2023 <br />GROUNDING: <br />IRONRIDGE INTEGRATED <br />CLAMP <br />MODEL # 1 <br />4"-20 <br />UL LISTED #2703 <br />THIS PROJECT WAS DESIGNED ON BEHALF OF AMERICAN ARRAY SOLAR. BY BLITZCONCEPTS & <br />DESIGNS. THE TEMPLATE IS THE SOLE PROPRIETOR OF BLITZ CONCEPT & DESIGNS <br />1. PV ARRAYS ARE PER SINGLE LINE.. <br />2. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT <br />WIRING. <br />3. USE UFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND <br />ELECTRODE PER N.E.C. 250.58. <br />4. ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. <br />5. CONNECTORS SHALL BE BLUE WIRE NUTS CONNECTORS. <br />6. INVERTER SHALL BE PER SINGLE LINE, SEE ATTACHED CUT SHEET. <br />7. AC DISCONNECT SHALL BE PER SINGLE LINE. <br />8. EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO NEC 690. <br />9. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE <br />THWN-2. <br />10. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5% <br />11. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. <br />12. ALL WORK TO COMPLY WITH 2022 CALIFORNIA ELECTRIC CODE, 2022 CALIFORNIA BUILDING CODE <br />13. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. <br />14. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED FROM SOLAR <br />ARRAY. <br />15. CONDUCTORS ON ROOF ARE TO BE 0.875" OFF OF THE ROOF SURFACE. <br />16.GEC TO BE CONNECTED TO EXISTING UFER. IF UFER IS NOT PRESENT THEN A NEW GROUND ROD WILL <br />BE ADDED FOR GROUNDNG PURPOSES. <br />RACKING & MODULES ARE GROUNDED VIA A CONTINUOUS #6AWG COPPER CONDUCTOR CONNECTED W/ <br />[IRONRIDGE INTEGRATED GROUNDING]. <br />DC SIDE OF ARRAY IS UNGROUNDED AND THEREFORE GEC IS NOT REQUIRED. <br />ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. <br />ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED <br />SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES 690.9 (A) <br />UTILITY METER <br />2109 N Poinsettia <br />St05/03/23