Laserfiche WebLink
46'-10" <br />11'12' <br />(E) <br />BEDROOM <br />#1 <br />(E) <br />BEDROOM <br />#2 <br />(E) <br />BEDROOM <br />#3 <br />CL <br />O <br />S <br />E <br />T <br />10 <br />' <br />(E) <br />KITCHEN <br />G <br />E <br />23'-10" <br />20' <br />5' <br />4' <br />14 <br />' <br />33 <br />' <br />4' <br />- <br />3 <br />" <br />19'-2" <br />10 <br />' <br />BEDROOM <br />#1 <br />BATH <br />#1 <br />REF <br />5'-6"13'-3" <br />15 15 <br />3'-6" <br />DW <br />RANGE <br />15 <br />" <br />15 <br />" <br />BATH <br />#2 <br />36 <br />" <br />W/D <br />4' <br />- <br />4 <br />" <br />3' <br />- <br />1 <br />0 <br />" <br />1' <br />- <br />8 <br />" <br />5' <br />- <br />6 <br />" <br />8' <br />- <br />9 <br />" <br />52 <br />" <br />KITCHEN <br />/DINING <br />BEDROOM #2 <br />LAUNDRY <br />#2 <br />LIVING <br />LAUNDRY <br />#1 <br />W/D <br />8'- 4" <br />36 <br />STORAGE 2 <br />5' <br />CL <br />O <br />S <br />E <br />T <br />CLOSET <br />3' <br />W1 <br />W1 <br />W1 <br />W2 <br />W1 <br />W2 <br />24 <br />' <br />' <br />W <br /> <br />X <br /> <br />3 <br />6 <br />' <br />' <br />H <br />SI <br />N <br />G <br />L <br />E <br /> <br />H <br />U <br />N <br />G <br />WI <br />N <br />D <br />O <br />W <br />24 <br />' <br />' <br />W <br /> <br />X <br /> <br />2 <br />4 <br />' <br />' <br />H <br />SL <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />W3 <br />W3 <br />24 <br />' <br />' <br />W <br /> <br />X <br /> <br />3 <br />6 <br />' <br />' <br />H <br />SI <br />N <br />G <br />L <br />E <br /> <br />H <br />U <br />N <br />G <br />WI <br />N <br />D <br />O <br />W <br />48''W X 48''H <br />SLIDING WINDOW <br />EGRESS <br />24''W X 24''H <br />SLIDING WINDOW <br />D1 <br />D1 <br />D3 <br />D3 <br />D3 <br />D4 <br />D4 <br />D4 <br />D4 <br />48 <br />' <br />' <br />W <br /> <br />X <br /> <br />4 <br />8 <br />' <br />' <br />H <br />SL <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />48 <br />' <br />' <br />W <br /> <br />X <br /> <br />4 <br />8 <br />' <br />' <br />H <br />SL <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />48 <br />' <br />' <br />W <br /> <br />X <br /> <br />4 <br />8 <br />' <br />' <br />H <br />SL <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />30'' WIDE <br />X 22'' DEPTH <br />ATTIC ACCESS <br />50CFM <br />EXHAUST <br />FAN. DUCTED <br />OUTSIDE <br />THE BUILDING. <br />50CFM EXHAUST <br />FAN. DUCTED <br />OUTSIDE THE <br />BUILDING. <br />EXISTING <br /> MAIN HOUSE <br />SD <br />SD <br />SD SD <br />SD <br />SD <br />CM <br />MA <br />I <br />N <br />EN <br />T <br />R <br />A <br />N <br />C <br />E <br />LINE OF PATIO COVER <br />LI <br />N <br />E <br /> <br />O <br />F <br /> <br />E <br />X <br />T <br />E <br />N <br />S <br />I <br />O <br />N <br />EXISTING PATIO <br />TO REMAIN, PROTECT <br />IN PLACE <br />REF <br />DW <br />W/D <br />CL <br />O <br />S <br />E <br />T <br />RA <br />N <br />G <br />E <br />WH <br />SD <br />CM <br />WH <br />SUPPLY <br />RETURN <br />3' <br />5' <br />LANDING <br />3' <br />- <br />6 <br />" <br />8' <br />LANDING <br />D2 <br />8'-8" <br />LANDING <br />3' <br />1' <br />4'-7" <br />2'-6"8'3'-6" <br />5' <br />14'-2" <br />20'46'-10" <br />EXISTING MAIN HOUSE15' <br />96''W X 80''H <br />SLIDING DOOR <br />EN <br />T <br />R <br />A <br />N <br />C <br />E <br />3'-6" <br />6' <br />LA <br />N <br />D <br />I <br />N <br />G <br />8' <br />- <br />4 <br />" <br />22 <br />' <br />- <br />6 <br />" <br />10 <br />' <br />32 <br />' <br />- <br />1 <br />" <br />8' <br />- <br />5 <br />" <br />2' <br />INDOOR FAN. <br />TYPICAL <br />LEGEND. <br />SPLIT TYPE. <br />CONDENSER <br />OF THE <br />HEAT PUMP <br />SPLIT TYPE <br />UNIT. <br />INDOOR FAN. <br />TYPICAL <br />LEGEND. <br />SPLIT TYPE. <br />(E) <br />LIVING <br />AREA <br />(E) DINING <br />AREA <br />PROVIDE AIRBORNE <br />SOUND INSULATION. <br />50STC RATING. SEE <br />DETAIL IN THIS SHEET. <br />PROVIDE 1-HR FIRE RATED <br />WALL ASSEMBLY. SEE <br />DETAIL IN THIS SHEET <br />SEE WATER HEATER <br />NOTE SHEET 1.1 <br />(E) <br />BATH#1 <br />(E) <br />BATH#2 <br />INDOOR FAN. <br />TYPICAL <br />LEGEND. <br />SPLIT TYPE. <br />DOOR SCHEDULE <br />TAG <br />1 <br />SIZE THICK MATERIALWIDE(") X HEIGHT(")TYPE GLAZING SELF-LATCH SELF-CLOSING <br />WINDOW SCHEDULE <br />TAG <br />1 <br />SIZE MATERIAL <br />GLASS, TEMPERED <br />WIDE(") X HEIGHT(") <br />48 48 <br />GLAZING <br />DOUBLE 0.32 <br />U-FACTOR <br />0.25 <br />SHGC TYPE <br />SLIDING <br />1 3/4''WOOD3680 <br />SLIDING <br />NO NO NO <br />2 <br />1 3/4'' <br />WOOD <br />36 <br />80 YES NO NO <br />3 GLASS <br />96 <br />80 YES NO NO <br />2 GLASS, TEMPERED2436 DOUBLE 0.32 0.25 <br />3 GLASS, TEMPERED DOUBLE 0.32 0.25 <br />HINGE <br />HINGE <br />4 1 3/4''WOOD2880 NO NO NOHINGE <br />1 3/4'' <br />SLIDING <br />24 24 SLIDING <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />NO.REVISIONS DATE <br />CONSULTANT <br />JOB NO: <br />DATE: <br />1ST REV: <br />DRAWN: <br />PLOTTED: <br />SCALE:AS SHOWN <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OW <br />N <br />E <br />R <br />: <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />T: 323.470.0181 E: kmassociatesince@outlook.com <br />KM ASSOCIATES INC. <br />16202 ORION AVE CHINO CA 91708 <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />A <br />D <br />U <br />21 <br />2 <br />2 <br /> <br />N <br />. <br /> <br />L <br />E <br />W <br />I <br />S <br /> <br />S <br />T <br />. <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />2 <br />2 <br /> <br />N <br />. <br /> <br />L <br />E <br />W <br />I <br />S <br /> <br />S <br />T <br />. <br /> <br /># <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />- <br />2 <br />2 <br />3 <br />6 <br />SHEET TITLE <br />SHEET NUMBER <br />LI <br />N <br />H <br /> <br />L <br />E <br /> <br />A <br />N <br />D <br /> <br />D <br />A <br />V <br />I <br />D <br /> <br />F <br />R <br />E <br />U <br />D <br />E <br />N <br />B <br />E <br />R <br />G <br />E <br />R <br />SCALE 1/4" = 1'-0"1.2 <br />PROPOSED FLOOR PLAN1 <br />LEGEND: <br />CMSD <br />1-HR FIRE-RATED WALL <br />50CFM ENERGY STAR COMPLIANT <br />AND BE DUCTED TO THE OUTSIDE OF <br />THE BUILDING. <br /> FANS, NOT FUNCTIONING AS A <br />COMPONENT OF A WHOLE HOUSE <br />VENTILATION SYSTEM, MUST BE <br />CONTROLLED BY A HUMIDITY <br />CONTROLLER. <br />SMOKE AND CARBON MONOXIDE <br />DETECTOR INTERCONNECTED <br />HARDWIRED WITH BATTERY BACKUP. <br />NOTES: <br />1.FINISH MATERIAL INCLUDING <br />SEALANTS, CAULK, PAINTS AND <br />COATINGS, ADHESIVES, CARPET <br />SYSTEMS, ETC.SHALL MEET THE (VOC) <br />EMISSION LIMITS PER LAC GBSC <br />CHAPTER 4. <br />2.OPENING SHALL HAVE <br />CORROSION-RESISTANT WIRE MESH OR <br />OTHER APPROVED MATERIAL WITH 1/16'' <br />MINIMUM AND 1/4'' MAXIMUM OPENING. <br />3.A MINIMUM OF 1'' AIRSPACE SHALL BE <br />PROVIDED BETWEEN INSULATION AND <br />ROOF SHEATHING. <br />4.CLOTHES DRYER MOISTURE EXHAUST <br />DUCT MUST BE 4" IN DIAMETER AND <br />LENGTH SHALL BE REDUCED BY 2' FOR <br />EVERY ELBOW IN EXCESS OF TWO. <br />BATHROOM NOTES: <br />* SHOWER FLOORS AND WALLS ABOVE <br />BATHTUBS WITH INSTALLED SHOWER <br />HEAD SHALL BE FINISHED WITH <br />NON-ABSORBENT SURFACE TO HEIGHT <br />NOT LESS THAN 6' ABOVE FLOOR. <br />ADDITIONAL NOTES: <br />1."ALL DUCT AND OTHER RELATED AIR <br />DISTRIBUTION COMPONENT OPENINGS <br />SHALL BE COVERED WITH TAPE, PLASTIC, <br />OR SHEET METAL UNTIL THE FINAL <br />STARTUP OF THE HEATING, COOLING <br />AND VENTILATING EQUIPMENT." <br />(4.504.1) <br />2."ARCHITECTURAL PAINTS AND <br />COATINGS, ADHESIVES, CAULKS AND <br />SEALANTS SHALL COMPLY WITH THE <br />VOLATILE ORGANIC COMPOUND (VOC) <br />LIMITS LISTED IN TABLES <br />4.504.1-4.504.3." <br /> 4.504.2.1-4.504.2.3 <br />ADDITIONAL NOTES ON ALARMS: <br />1.THE ALARM SHALL PROVIDE AN AUDIBLE <br />WARNING WHEN THE DOOR OR ITS SCREEN, IF <br />PRESENT, ARE OPENED. <br />2.THE ALARM(S) SHALL BE LISTED AND LABELED <br />IN ACCORDANCE WITH UL 2017 AND <br />INDEPENDENTLY CERTIFIED TO THE ASTM <br />STANDARD F2208. <br />3.THE ALARMS SHALL BE EQUIPPED WIT H A <br />DEACTIVATION SWITCH LOCATED IN <br />ACCORDANCE 54" ABOVE THE FLOOR FOR <br />UNITS NOT REQUIRED TO BE ACCESSIBLE, <br />AND BETWEEN 48 AND 54 INCHES FOR UNITS <br />REQUIRED TO BE ACCESSIBLE. <br />1.2 <br />2122 N Lewis St & #2 <br />101118132-338/13/2024