NON-SHRINK GROUT #23616FIVE STAR GROUT <br />HOLD-DOWNS SIMPSON HOLD-DOWNS #24818 <br />#24947, #25076SIMPSON JOIST HANGERSJOIST HANGERS <br />#22086SIMPSON FTA5 STRAPSTRAPS <br />SET "XP" EPOXY #25279SIMPSON EPOXY ANCHOR <br />LARR NUMBERS <br />SEISMIC DESIGN CRITERIA <br />a) Importance Factor, i = 1 <br />b) Exposure = C <br />c) Wind Velocity = 110 MPH <br />WIND DESIGN CRITERIA <br />C.REINFORCING STEEL <br />H.NAILING SCHEDULE <br />COMMON WIRE NAILS <br />1.JOIST TO SILL OR GIRDER TOE NAIL---------------------------------------------------------------------------------------------3-8d <br />2. BRIDGING TO JOIST TOE NAIL EACH END--------------------------------------------------------------------------------------2-8d <br />3. 1" BY 6" SUBFLOOR OR LESS TO EACH JOIST FACE NAIL----------------------------------------------------------------2-8d <br />4. WIDER THAN 1" BY 6" SUBFLOOR TO EACH JOIST FACE NAIL----------------------------------------------------------3-8d <br />5. 2" SUBFLOOR TO JOIST OR GIRDER BLIND AND FACE NAIL-----------------------------------------------------------2-16d <br />6. SOLE PLATE TO JOIST OR BLOCKING FACE NAIL--------------------------------------------------------------16d @16" O/C <br />7. TOP PLATE TO STUD END NAIL---------------------------------------------------------------------------------------------------2-16d <br />8. STUD TO SOLE PLATE TOE NAIL---------------------------------------------------------------------------------------------------4-8d <br />9. DOUBLED STUDS FACE NAIL------------------------------------------------------------------------------------------16d @24" O/C <br />10. DOUBLED TOP PLATES FACE NAIL----------------------------------------------------------------------------------16d @16" O/C <br />11. TOP PLEATES, LAPS & INTERSECTIONS FACE NAIL----------------------------------------------------------------------2-16d <br />12. CONTINUOUS HEADER, TWO PIECES ALONG EACH SIDE--------------------------------------------------16d @16" O/C <br />13. CEILING JOISTS TO PLATE FACE NAIL-------------------------------------------------------------------------------------------3-8d <br />14. CONTINUOUS HEADER TO STUD TOE NAIL------------------------------------------------------------------------------------4-8d <br />15. CEILING JOISTS, LAPS OVER PARTITIONS FACE NAIL-------------------------------------------------------------------3-16d <br />16. CEILING JOISTS TO PARALLEL RAFTERS FACE NAILS-------------------------------------------------------------------3-16d <br />17. RAFTER TO PLATE TOE NAIL--------------------------------------------------------------------------------------------------------3-8d <br />18. 1 BY BRACE TO EACH STUD AND PLATE FACE NAIL-----------------------------------------------------------------------2-8d <br />19. 1 BY 8 SHEATING OR LESS TO EACH BEARING FACE NAIL--------------------------------------------------------------2-8d <br />20. WIDER THAN 1 BY 8 SHEATHING TO EACH BEARING FACE NAIL------------------------------------------------------3-8d <br />21. BUILT-UP CORNER STUDS----------------------------------------------------------------------------------------------16d @24" O/C <br />22. BUILT-UP GIRDER AND BEAMS: <br />AT TOP & BOTTOM & STAGGERED--------------------------------------------------------------------------------20d @32" O/C <br />AT ENDS & AT EACH SPLICE-----------------------------------------------------------------------------------------------------2-20d <br />23. 2 BY PLANKS AT EACH BEARING-------------------------------------------------------------------------------------------------2-16d <br />GENERAL NAILING NOTES <br />A. GENERAL NOTES <br />D. SHEAR WALL <br />E. LUMBER / FRAMING <br />11. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH OF THE FOLLOWING GRADES UNLESS <br />NOTED OTHERWISE: <br />PLYWOOD PANELS--------------------------STRUCTURAL I OR II, CDX EXT. GLUE CONFORMING TO PS-1-83 <br />PLATES, BLOCKING-------------------------------------------------------------------------------------------------CONST. -875fb <br />BEAMS, STRINGERS (4x)-------------------------------------------------------------------------------------------------#1-1000fb <br />POST & BEAMS (>4x)-------------------------------------------------------------------------------------SEL. STRUCT. -1600fb <br />ROOF PLANKING & DECKING-------------------------------------------------------------------------------COM. DEX. -875fb <br />JOISTS & PLANKING--------------------------------------------------------------------------------------------------------#2 -875fb <br />RAFTERS ----------------------------------------------------------------------------------------------------------------------#2 -875fb <br />BOARDS, SHEATHING & STRIPPING------------------------------------------------------------------------CONST. GRADE <br />SILLS, PLATES, SLEEPERS, POSTS OR WOOD EMBEDDED <br />IN CONCRETE SLAB WHICH IS IN CONTACT WITH EARTH ------ CONST. GRADE, PRESSURE TREATED <br />MISC. NAILING STRIPS & BLOCK EMBEDDED IN CONCRETE <br />OR MASONRY------------------------------GRADE SPECIFIED ABOVE, TANK DIPPED IN SALT PERSERVATIVE <br />12. ALL BREAKS FOR VENTS, DUCTS, PLUMBING SHALL BE STRAPPED WITH 1 1/2 x 1/8 STEEL STRAPS <br />WITH 4-16d NAILS EACH SIDE. <br />13. HEADER SIZE NOT SHOWN SHALL BE PER UBC STANDARDS AND 4x4 MIN. <br />14. PROVIDE HOLDDOWNS (FTA, HD, PA, VERT. MST, ETC.) W/ DBL OR 4x STUD WITH E.N. <br />15. HANGER FOR 2x JST SHALL BE SIMPSON "U", FOR 4x OR 6x PURLIN SHALL BE SIMPSON "HUTF", U.N.O. <br />16. DBL. JOIST SHALL BE NAILED TOGETHER WITH 16d @ 9" O.C., STAGGER, U.N.O. <br />17. TIE ROOF RAFTERS AT RIDGE W/ ST 2115 @ 4'-0" 0/C. <br />18. NOTCHING OF EXTERIOR AND BEARING / NONBEARING WALLS SHALL NOT EXCEED 25% / 40% <br />RESPECTIVELY. BORED HOLES IN BEARING / NONBEARING WALLS SHALL NOT EXCEED 40% / 60% <br />RESPECTIVELY. <br />19. PLYWOOD ROOF PANELS SHALL BE BONDED WITH INTERMEDIATE OR EXTERIOR GLUE AND BE OF <br />EXTERIOR TYPE WHERE EXPOSED TO THE WEATHER. <br />20. DOUBLE JOISTS ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS. U.N.O. <br />21. THE REQUIRED CLEARANCE FOR WOOD MEMBERS ABOVE GRADE, IS 6" FOR MUDSILLS, 12" FOR <br />GIRDERS, AND 18" FOR JOISTS. <br />22. ROOF DIAPHRAGM SHALL BE 1/2" PLYWOOD, PANEL INDEX 24/0, NAIL 8d @ 6", 12". FLOOR DIAPHRAGM <br />SHALL BE 5/8" PLYWOOD, PANEL INDEX 32/16, T&G, NAIL 10d @ 6", 10", U.N.O. <br />23. LAY PLYWOOD PANEL STAGGERED W/ FACE GRAIN PERPENDICULAR TO SUPPORTS. <br />24. ALL DOUBLE TOP PLATES ARE TO BE CONTINUOUS BY NAILING OR STRAPS. SPLICE @4'-0"MIN. <br />W/12-6d NAILS EACH SIDE OF SPLICE WHERE INTERRUPTED, TIE TOP PLT'S W/ SIMPSON MST 37, <br />U.N.O. <br />25. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION. <br />26. EACH SHEET OF PLYWOOD SHALL CONTAIN A MINIMUM OF (8) SQ. FT. AND SHALL EXTEND TO (3) <br />BEARINGS MINIMUM WITH FACE-GRAIN PERPENDICULAR TO JOISTS. <br />27. PROVIDE EDGE NAILING OVER ALL WALLS, LAMINATED BEAMS, STRUTS AND ALL AROUND OPENINGS. <br />28. PROVIDE BOUNDARY NAILING AT PERIMETER OF BUILDING AND AT ALL CONTINUOUS PLYWOOD <br />EDGES. <br />29. PROVIDE FULL BEARING ON ALL BEAMS AND JOISTS HANGERS; IF EXCESSIVE SHRINKAGE OCCURS, <br />PROVIDE HANDWARE SHIMS, WHICH SHALL BE SECURED TO JOISTS. <br />B. CONCRETE <br />F.STATEMENT OF SPECIAL INSPECTION <br />NOTE: <br />G.FOUNDATION DESIGN CRITERIA <br />a) Importance Factor, i = 1 <br />b)Fa = 1.2 ; Fv = 1.83 <br />c)Ss=1.331, .02 sec response S1=0.473, 1.0 sec response <br />d) Site Class = D <br />e)Sds = 1.065 Sd1 = 0.576 <br />f) Seismic Design Category = D <br />g) Basic Seismic Force Resisting System= Wood Shear Wall; <br />h) Cd = 4.0 <br />i) R = 6.5 <br />j) Omega = 3.0 <br />k)hn' = 10.5' <br />Ta = 0.117 sec <br />n) Redundancy Factor = 1.3 <br />o)Cs = 0.1638 <br />p) Analysis Procedure Used = Per 2022 CBC, 2022 CRC <br />ASCE 7-16. <br />1.HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS;AND <br />HOLD-DOWNS SHALL BE TIGHTENED JUST PRIOR TO CONVERING THE WALL FRAMING. CONNECTOR <br />BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS IN ACCORDANCE WITH TABLE <br />2306.5 OF THE CITY/COUNTY BUILDING CODE. (2306.5) <br />2. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD <br />SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR <br />BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 <br />3. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. <br />4.ALL BOLT HOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED. (11.1.2.2, '05 NDS) <br />5. HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. <br />6. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD <br />SHALL BE PERPENDICULAR TO THE SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE <br />BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 <br />7. ALL DIAPHRAGMS AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. <br />8.ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. <br />1.CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING <br />SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A <br />WRITTEN STATEMENT OF RESPONSIBILITY TO THE CITY INSPECTORS AND THE OWNER PRIOR TO <br />THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC. 1706.1. <br />2. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD <br />WELDING, CONCRETE STRENGTH F'C>2500PSI, ENGINEERED MASONRY, HIGH-LIFT GROUTING. <br />3.FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. <br />(2304.11.2.4) <br />4.FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE CITY FOR (STRUCTURAL STEEL) <br />(REINFORCING STEEL) (LIGHT GAUGE STEEL). CONTINUOUS INSPECTION BE A DEPUTY INSPECTOR <br />IS REQUIRED. <br />5.SHOP WELDS MUST BE PERFORMED IN A LICENSED FABRICATOR'S SHOP. <br />6.LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. <br />7. GLULAM BEAMS MUST BE FABRICATED IN A LICENSED SHOP. IDENTIFY GRADE SYMBOL AND <br />LAMINATION SPECIES PER T 5-A, 2005 NDS SUPP. <br />8. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SHANK PORTION <br />9. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND <br />10. A COPY OF THE RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE <br />AVAILABLE AT THE JOB SITE. <br />1.ALL CONCRETE SHALL CONFORM TO THE 2022 CALIFORNIA RESIDENTIAL CODE AND CBC. <br />2. CONCRETE SHALL BE DESIGNED AND TESTED AS OUTLINED IN THE SPECS. <br />3.ALL CEMENT SHALL CONFORM TO A.S.T.M. (C-150), TYPE I OR II <br />4.FINE AND COARSE AGGREGATE SHALL CONFORM TO A.S.T.M. (C-33) FOR STANDARD WEIGHT <br />CONCRETE AND A.S.T.M. (C-330) FOR LIGHT WEIGHT CONCRETE. <br />5.ALL AGGREGATE SHALL BE COMPARABLE TO "SAN GABRIEL VALLEY" AGGREGATE. THE SHRINKAGE <br />SHALL BE PER A.S.T.M. (C-157) WITH THE AVERAGE DRYING SHRINKAGE AT (28 DAYS) OF DRYING NOT <br />EXCEEDING (0.04%) <br />6.DRYPACK SHALL BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT MORE THAN THREE <br />PARTS SAND. <br />7.ANCHOR BOLTS, DOWELS, INSERTS, ETC. SHALL BE SECURELY TIED IN PLACE PRIOR TO POURING <br />CEMENT. <br />8.LOCATION OF CONSTRUCTION JOINTS OR POUR JOINTS SHALL BE APPROVED BY THE STRUCTURAL <br />ENGINEER PRIOR TO POURING CONCRETE. <br />9.CONCRETE SHALL BE CURED BY KEEPING CONTINUOUSLY WET FOR (10 DAYS) OR BY AN APPROVED <br />CURING COMPOUND. <br />10. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR <br />MISCELLANEOUS ITEMS TO BE CAST INTO CONCRETE AND FLOOR DEPRESSIONS, ETC. <br />11. SEE ARCHITECTURAL DRAWINGS FOR LOCATION OF EXPANSION JOINTS, SCORING, ETC. FOR <br />CONCRETE WALKS AND SLABS. <br />12. FOOTING AND GRADE BEAM SHALL BE F'c=2,500 PSI AT 28 DAYS. <br />12. ALL CONCRETE STRUCTURES SHALL HAVE A MINIMUM COMPRESSION STRENGTH OF F'c = 3,000 PSI <br />AT 28 DAYS, UNLESS NOTED OTHERWISE. <br />13. PROVIDE INTERIOR SLAB CONTROL JOINTS AT MAXIMUM 20FT. O.C. EACH WAY. <br />14. NO WOOD OR STEEL STAKES SHALL BE PERMITTED TO BE LEFT IN FOOTINGS. <br />15. BOT. OF FTG. SHALL BE 18" MIN. FOR 1-STORY BLDG., 24" MIN. FOR 2-STORY BLDG., 24" MIN. FOR <br />3-STORY BLDG. OR EXPANSIVE SOIL BELOW NATURAL GRADE, U.N.O. <br />16. ALL PADS SHALL BE 14" THICK MIN. W/ #4 @ 12" E.W. AR BOT., U.N.O. <br />1.ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE, CONFORMING TO A.S.T.M.(A-615-40), U.N.O. <br />2.USE LOW HYDROGEN ELECTRODES, GRADE (E-70), FOR WELDING REINFORCING BARS. <br />3.REINFORCING BARS MARKED CONT. SHALL BE SPLICED WITH A MINIMUM LAP OF (40) BAR DIAMETERS IN <br />MASONRY AND (36) DIAMETERS IN CONCRETE. <br />4.ALL REINFORCING SHALL BE SECURELY TIED AND BRACED IN PLACE PRIOR TO POURING CONCRETE OR <br />PLACING MASONRY. <br />5.PROVIDE THE FOLLOWING MINIMUM PROTECTIVE COVERING OF CONCRETE OVER REINFORCING STEEL. <br />BELOW GRADE (UNFORMED)----------------3" CLR. BELOW GRADE (FORMED)--------------------2" CLR. <br />1.ALL STRUCTURAL LUMBER SHALL BE GRADED IN ACCORDANCE WITH THE "GRADING AND DRESSING <br />RULES(#16) OF THE WEST COAST LUMBERMAN'S ASSOCIATION". <br />2.ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED DOUGLAS FIR OR <br />CONSTRUCTION GRADE REDWOOD. <br />3.HOLES FOR BOLTS SHALL BE BORED WITH A BIT(1/32" TO 1/16") LARGER THAN THE NORMAL BOLT <br />DIAMETER. ALL BOLTS SHALL BE RE-TIGHTENED PRIOR TO APPLICATION OF PLYWOOD, PLASTER, <br />ETC. <br />4.STRUCTURAL MEMBERS SHALL NOT BE CUT FIR PIPES, ETC. UNLESS SPECIFICALLY NOTED OR <br />DETAILED. <br />5.2x SOLID BLOCKING SHALL BE PLACED BETWEEN JOISTS OR RAFTERS AT ALL SUPPORTS. <br />6.CROSS-BRIDGING SHALL BE PROVIDED AT (8'-0" 0/C) MAX. FOR ALL FLOOR JOISTS OVER (4") IN DEPTH <br />AND ALL ROOF JOISTS OVER (6") IN DEPTH. USE 2x3 OR SOLID BLOCKING OR AN APPROVED TYPE <br />METAL BRIDGING. <br />7.ALL STRUCTURAL PLYWOOD SHALL BE STRUCTURAL I OR II (C-D) GRADE WITH EXTERIOR GLUE AND <br />CONFORM TO (PS-1-83). EACH SHEET SHALL BE IDENTIFIED BY A REGISTERED STAMP OR BRAND OF <br />THE "TECO, D.F.P.A. OR PITTSBURGH TESTING LABORATORY". <br />8.ALL BOLTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS UNDER HEAD AND NUT, <br />UNLESS NOTED OTHERWISE. <br />9.PROVIDE 1x6 DIAGONAL LET-IN BRACE AT APPROXIMATELY 45" EVERY (25'-0") IN ALL STUD WALLS NOT <br />PLYWOOD SHEATHED. BRACING SHALL CONTINUE FROM TOP PLATES TO SILL PLATE OR USE <br />SIMPSON CWB METAL WALL BRACES. <br />10.ALL JOIST HANGERS SHALL BE "SIMPSON" OR AN APPROVED EQUAL. <br />1. GENERAL: REFER TO CHAPTER 17 OF THE 2022 CBC FOR AMPLIFICATION OF, AND/OR EXCEPTIONS TO, <br />THE FOLLOWING REQUIREMENTS (E.G., WELDING, ETC.). ALL SPECIAL INSPECTORS MUST SUBMIT <br />FINAL REPORTS. <br />2. INSPECTORS: ALL TESTS AND INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT INSPECTION <br />AGENCY. JOB SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE, AND ARE NOT A <br />SUBSTITUTE FOR, INSPECTIONS BY AN INDEPENDENT INSPECTION AGENCY. ALL TESTING AND I <br />INSPECTION REPORTS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT. THE FINAL REPORT BY <br />THE TESTING AND INSPECTION AGENCIES MUST CERTIFY THAT THE ENTIRE STRUCTURAL SYSTEM <br />COMPLIES WITH THE APPROVED PLANS AND SPECIFICATIONS. SUBMIT ALL TEST & INSPECTION <br />REPORTS TO ENGINEER OF RECORD. <br />3. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT THESE TEST AND INSPECTION <br />ARE PERFORMED. (T2306.4.1) <br />A. WOOD NAILED 4" O.C. OR CLOSER <br />B. EPOXY ANCHORS / ADHESIVE ANCHORS <br />1. THERE IS NO SOIL'S REPORT PREPARED FOR THIS PROJECT. USE THE WORST <br />CONDITION AS PRESCRIBED ON CBC 2022 - TABLE R401.4.1 <br />LOAD BEARING PRESSURE = 1,500 PSF <br />1. NAILS SHALL BE DRIVEN PERPENDICULAR WHERE POSSIBLE INSTEAD OF TOE NAILS. <br />2. PRE-DRILL FOR ALL NAILS 30d OR LARGER. <br />3. ALL NAILS SHALL BE COMMON WIRE NAILS UNLESS OTHERWISE NOTED.SHEAR WALL SCHEDULE <br />PANEL <br />NAILINGTYPE <br />DESCRIPTION <br />OF SHEAR WALL <br />MATERIAL <br />15/32" PLYWD. <br />STRUCTURAL 1 <br />PERIMETER FIELD <br />10D @ <br />4"O.C. <br />BLKG. TO PLATE <br />CONNECTION <br />REQUIREMENT <br />A35 @16" O.C. OR <br />LPT4 @16"O.C. <br />PLATE TO <br />BLKG. <br />CONNECT. <br />. <br />SDS 1/4"x6 <br />@16" O.C. <br />ANCHOR BOLTS <br />SILL PLATE TO <br />FOUND CONN. <br />5/8"Ø @32"O.C. <br />ANCHOR <br />BOLTS <br />EMB. <br />ALLOWABLE <br />SHEAR LOAD <br />PLF <br />280 PLF (4''-12'') <br />185 PLF (6''-12'') <br />S 10D @ <br />12"O.C. <br />FIELD NAILING <br />OVER 15" WIDE <br />WALL OPEING <br />SEE NOTE #4 <br />STUD FULL HT. <br />EDGE NAIL THRU <br />(2) 2X TOP PLATE <br />. <br />LESS THAN OR <br /> EQUAL TO 7" <br />.4' <br />(N) FOOTING <br />3X6 BOT. PLATE <br />NOTES: <br />1. NAILS SHALL BE 1/2" MIN. EDGE DISTANCE FROM EDGE OF PLYWOOD AND EDGE OF <br />STUD. USE COMMON NAILS ONLY. <br />2. USE 2X EDGE STUDS & BLK'G. WHERE NAIL SPACING IS LESS THAN 6" O.C. FOR 10d <br />NAILS AND WHERE CALLED OUT IN PLANS AND DETAILS.USE 2X SILL PLATE AT SHEAR <br />WALLS B,C,D AND E ONLY WHERE SILL PLATE RESTS ON CONCRETE. <br />3. PROVIDE 3/4" NAIL EDGE DISTANCE AT 3X STUDS AND BLK'G. <br />4. AT OPENING IN SHEAR PANEL OVER 15" WIDE,PROVIDE SOLID BLK'G AT HEAD AND SILL <br />LEVEL,EACH SIDE OF OPENING STRAP WITH 1"X16 GA X 3 TIMES OPENING WIDTH GALV. <br />METAL STRAP NAIL 8d @ 2" O.C. <br />5. NAILING WITH MACHINE NAILS SHALL CONFORM TO THE WOOD GENERAL NOTES. <br />6. ALL DEFECTIVE NAILS SHALL BE REMOVED AND REPLACED WITH SOUND NAILING <br />7. PLYWOOD SHEATHING SHALL BE PER SHEARWALL SCHEDULE BELOW U.N.O. PROVIDE <br />FRAMING MEMEBER OR BLOCKING AT ALL EDGES PER SCHEDULE. PROVIDE EDGE <br />NAILING TO END STUD OR POST WHERE HOLDOWN OCCURS AND TO ALL OTHER POSTS <br />IN SHEARWALLS. <br />8. SILL PLATES SHALL BE PRESSURE TREATED D.F. AND CONFORM TO SILL PLATES <br />DETAILS. PROVIDE MINIMUM OF 3 ANCHOR BOLTS IN ALL SHEAR WALLS. <br />9. WHERE PLYWOOD IS ON TWO SIDES OF WALL,THE SPACINGS OF ANCHOR BOLT AND <br />AS35 SHOULD BE REDUCED TO HALF THE SPACING SHOWN ON THE TABLE. STAGGER <br />NAILING AND JOINTS. <br />10. ALL SHEARWALLS NAILING,ANCHOR BOLT INSTALLATION,HOLDOWN INSTALLATION <br />AND OTHER ELEMENTS OF SHEARWALL ASSEMBLY SHALL BE INSPECTED BY THE <br />ENGINEER OF RECORD, A CERTIFICATE OF INSPECTION MUST BE SUBMITTED TO THE <br />ENGINEER OF RECORD AND TO THE BUILDING DEPARTMENT.THE BUILDING OWNER <br />SHALL BE RESPONSIBLE FOR THE THE INSPECTOR FOR PERFORMING THE <br />STRUCTURAL OBSERVATION. <br />11. PLYWOOD SHEARWALLS SHALL BE COVERED WIHT 2 LAYERS OF 15# FELT <br />UNDERLAYMENT PRIOR TO PLACING FINISH MATERIALS. <br />12. STAGGER NAILS IF NAIL SPACING IS LESS THAN 3" O/C <br />13. ANCHOR BOLTS - DESIGN INCLUDES REDUCED EDGE DISTANCE. DEPUTY INSPECTOR <br />IS REQUIRED. <br />E.N. ALL POST <br />W/N WALL TYPICAL <br />E.N. PERIMETER OF EACH <br />PLYWOOD SHEET SEE PLAN <br />AND SCHED. FOR PLYWD <br />SIZE AND NAIL SPACING <br />STAGGER <br />PYWOOD PANELS <br />E.N. AT ALL OPENINGS <br />SEE NOTE #4 FOR <br />OPENING LARGER <br />THAN 15" <br />MAX. OPN'G. SIZE 16" SQ <br />ONE OPN'G. PER 8" OF <br />WALL WITHOUT SPECIAL <br />APPROVAL FROM <br />BLDG INSPECTOR <br />EDGE STUDS <br />& BLK'G <br />SEE NOTE #2 <br />5/8" BOLT W/ WASHER <br />3" X 3" X 3/8" <br />SPACED @ 32" O.C. <br />W/ SIMP. STRONG-TIE SET <br />ADHESIVE, SET PAC <br />16" <br />MINIMUM <br />E.N. ALL POST <br />W/N WALL,TYPICAL <br />9'' FOR CAST-IN-PLACE <br />CONCRETE. 6'' WITH SIMP'S <br />SET XP EPOXY POST <br />INSTALLED ANCHORS <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br />NOTE: THIS PLAN AND DETAILS ARE <br />APPLICABLE TO BOTH ADU MIRROR <br />IMAGE PER PLAN ALL SHEETS. <br />NO. REVISIONS DATE <br />CONSULTANT <br />JOB NO: <br />DATE: <br />1ST REV: <br />DRAWN: <br />PLOTTED: <br />SCALE: AS SHOWN <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OW <br />N <br />E <br />R <br />: <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />T: 323.470.0181 E: kmassociatesince@outlook.com <br />KM ASSOCIATES INC. <br />16202 ORION AVE CHINO CA 91708 <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />A <br />D <br />U <br />21 <br />2 <br />2 <br /> <br />N <br />. <br /> <br />L <br />E <br />W <br />I <br />S <br /> <br />S <br />T <br />. <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />2 <br />2 <br /> <br />N <br />. <br /> <br />L <br />E <br />W <br />I <br />S <br /> <br />S <br />T <br />. <br /> <br /># <br />2 <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />- <br />2 <br />2 <br />3 <br />6 <br />SHEET TITLE <br />SHEET NUMBER <br />LI <br />N <br />H <br /> <br />L <br />E <br /> <br />A <br />N <br />D <br /> <br />D <br />A <br />V <br />I <br />D <br /> <br />F <br />R <br />E <br />U <br />D <br />E <br />N <br />B <br />E <br />R <br />G <br />E <br />R <br />3.0 <br />PROPOSED GARAGE CONVERSION TO ADU <br />2122 N. LEWIS ST. AND 2122 N. LEWIS ST. #2, <br />SANTA ANA, CA 92706 - 2236 <br />LINH LE AND <br />DAVID FREUDENBERGER <br />2122 N Lewis St & #2 <br />101118132-338/13/2024