My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2109 W Flora St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Flora St
>
2109 W Flora St
>
2109 W Flora St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:01:55 PM
Creation date
6/1/2025 12:01:34 PM
Metadata
Fields
Template:
Plan
Permit Number
20178424
101113462
Full Address
2109 W Flora St
Document Relationships
101113462 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Flora St\2109 W Flora St
20178424 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Flora St\2109 W Flora St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE:V I N C I & A S S O C I A T E S SHEET:2 <br />PROJECT:Serrano Structural Engineers JOB NO.:22-3457 <br />2109 West Flora St 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV <br />Santa Ana, CA 805.496.2100 • VinciSE.com <br />CLIENT:Titan Solar Power <br />DESIGN CONNECTION TO ROOF TO RESIST WIND UPLIFT <br />REFER TO NEXT SHEET FOR <br />UPLIFT FORCE CALCULATIONS <br />ZONE 1 UPLIFT = -.6(2.58psf) <br />Design Force = ( Uplift x (0.6) ) -.6(2.58psf) <br />Net Uplift = <br />ADD 2.15 Connections per Module (MIN) <br />CONNECTION 27 Modules, 58 Connections <br />DETAIL Max Trib Area =ft2 <br />HERE UPLIFT / CONN. = 12.3 ft2 x 8.1 psf <br /> = 99.31 lbs/conn <br />PER 2018 NDS (TABLE 12.2A) <br />PALLOW = 256 lbs/in x CD x Ct <br />for (1) screw <br />WITH 2.00'' PENETRATION INTO JOIST <br />PALLOW = 2.00 '' x 410 lbs/in <br /> = 819.2 lbs > 99 lbs <br />Therefore O.K. <br />FACTOR OF SAFETY: <br />F.O.S. = 8.25 > 1.5 <br />Therefore O.K. <br />ZONE 3 UPLIFT = - 0.6 (2.58 psf)ZONE 2 UPLIFT = -.6(2.58psf) <br />Design Force = ( Uplift x (0.6) ) - 0.6 (2.58 psf)Design Force = ( Uplift x (0.6) ) -.6(2.58psf) <br />Net Uplift = Net Uplift = <br />2.15 Connections per Module (MIN)2.15 Connections per Module (MIN) <br />27 Modules, 58 Connections 27 Modules, 58 Connections <br />Max Trib Area = ft2 Max Trib Area = ft2 <br />UPLIFT / CONN. = 8.226 ft2 x UPLIFT / CONN. = 12.33 ft2 x <br /> = 169 lbs/conn = 253.3 lbs/conn <br />PER 2018 NDS (TABLE 12.2A)PER 2018 NDS (TABLE 12.2A) <br />PALLOW = 256 lbs/in x CD x Ct PALLOW = 256 lbs/in x CD x Ct <br />for (1) screw for (1) screw <br />WITH 2.00'' PENETRATION INTO JOIST WITH 2.00'' PENETRATION INTO JOIST <br />PALLOW = 2.00 '' x 409.6 lbs/in PALLOW = 2.00 '' x 410 lbs/in <br /> = 819.2 lbs > = 819.2 lbs > <br />Therefore O.K.Therefore O.K. <br />FACTOR OF SAFETY:FACTOR OF SAFETY: <br />F.O.S. = 4.85 > 1.5 F.O.S. = 3.23 > 1.5 <br />- <br />12.33 <br />5/16 in <br />5/16 in <br />12.33 <br />20.5 psf <br />12/13/2022 <br />8.1 psf <br />16.0 psf <br />36.8 psf 36.8 psf <br />20.5 psf <br />253 lbs <br />20.5 psf <br />5/16 in <br />8.23 <br />Therefore O.K. <br />20.5 psf <br />169 lbs <br />Therefore O.K. <br />2109 W Flora St <br />01/27/23
The URL can be used to link to this page
Your browser does not support the video tag.