S-1.1 <br />General Notes <br />20 PsfROOF LIVE LOAD: <br />10.0 PsfROOF DEAD LOAD: <br />STRUCTURAL PLANS - SHEET INDEX <br />S-1.1 General Notes <br />S-1.2 Notes and Nailing Schedule <br />S-2.1 Roof Framing Plan & Details <br />S-2.2 Foundation Plan & Details <br />1. ALL INFORMATION SHOWN ON THE DRAWINGS IS GIVEN AS THE BEST <br />PRESENT KNOWLEDGE WITHIN GENERALLY ACCEPTED ENGINEERING <br />PRACTICE BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUALLY <br />CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO <br />THE ENGINEER SO THAT THE PROPER REVISIONS MAY BE MADE PRIOR TO <br />PROCEEDING WITH THE WORK. MODIFICATIONS OF DETAILS OF <br />CONSTRUCTION OR DEVIATIONS FROM THE PLANS SHALL BE MADE ONLY <br />WITH THE WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER. <br />2. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR: <br />A. ALL CONTRACT DOCUMENTS. <br />B.OMISSIONS AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF <br />THE CONTRACT DOCUMENTS. <br />C. ALL DIMENSIONS AND CONDITIONS AT THE SITE. <br />D.ANY CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY <br />OF THE STRUCTURE. <br />E. INSURING PROPER ALIGNMENT OF FINAL STRUCTURE. THE CONTRACTOR <br />SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL <br />ENGINEER OF ANY DISCREPANCY OR OMISSION BEFORE PROCEEDING WITH <br />THE WORK AND GET WRITTEN APPROVAL FOR ALTERNATE CONSTRUCTION. <br />3.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL REGULATING <br />AGENCIES EXERCISING AUTHORITY OVER ANY PORTION OF THE WORK, I.E. <br />STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY AND CAL/OSHA, ETC., <br />AND SHALL CONFORM TO THE CURRENT CALIFORNIA BUILDING CODE OR <br />LOCAL CODES. <br />4. ALL WORK SHALL CONFORM TO THE BEST PRACTICE PREVAILING IN THE <br />VARIOUS TRADES COMPRISING THE WORK. <br />5. THE DESIGN, ADEQUACY AND SAFETY OF ERECTION, BRACING, SHORING, <br />TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE <br />CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE ENGINEER. <br />6. THE CONTRACTOR SHALL PROVIDE SAFE AND ADEQUATE BRACES AND <br />CONNECTIONS TO SUPPORT THE COMPONENT PARTS OF THE STRUCTURE <br />UNTIL THE STRUCTURE ITSELF (INCLUDING THE ROOF AND FLOOR <br />DIAPHRAGMS) IS COMPLETE ENOUGH TO ADEQUATELY SUPPORT ITSELF. <br />7. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL <br />NOTES AND TYPICAL DETAILS. OPTIONS, IF PROVIDED HEREIN, ARE FOR THE <br />CONTRACTOR'S CONVENIENCE. THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR ALL CHANGES NECESSARY, SHALL COORDINATE ALL DETAILS, SHALL <br />OBTAIN ALL REQUIRED APPROVALS, AND PAY ALL COSTS INCIDENT THERETO. <br />8. NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN BEAMS, <br />SLABS, OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED. NOR SHALL <br />ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS <br />OTHERWISE NOTED. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR <br />INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. REFER TO <br />ARCHITECTURAL AND MECHANICAL DRAWINGS FOR LOCATIONS. <br />9. WORK THESE DRAWINGS WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, <br />CIVIL, AND OTHER DESIGN DRAWINGS. <br />10. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR <br />MATERIALS, SUCH AS STANDARDS SHALL BE THE LATEST EDITION AND ALL <br />ADDENDUM. <br />11. AS A CONVENIENCE TO THE CONTRACTOR, THE ENGINEER SHALL REVIEW <br />SHOP DRAWINGS AS TO THEIR CONFORMANCE TO THE DESIGN CONCEPT. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DIMENSIONS, <br />QUANTITIES, TECHNIQUES OF CONSTRUCTION AND COORDINATION WITH <br />OTHER TRADES. SHOP DRAWINGS ARE REQUIRED FOR THE FOLLOWING: <br />PRECAST CONCRETE ELEMENTS <br />STRUCTURAL STEEL <br />GLUED LAMINATED WOOD <br />NON-STANDARD TIMBER CONNECTIONS <br />12. VIBRATIONAL EFFECTS OF MECHANICAL EQUIPMENT HAVE NOT BEEN <br />CONSIDERED BY THE STRUCTURAL ENGINEER IN THE DESIGN OF THE <br />STRUCTURE. MECHANICAL EQUIPMENT SHALL THEREFORE BE ISOLATED TO <br />ELIMINATE VIBRATIONAL EFFECTS. <br />13. WHERE DESIGN AND DETAIL OF PLATE GIRDERS, TRUSSES, ETC. IS TO BE <br />PROVIDED BY THE FABRICATOR, CONTRACTOR SHALL SUBMIT <br />CALCULATIONS PREPARE BY A LICENSED CIVIL ENGINEER OR STRUCTURAL <br />ENGINEER TO THE PROJECT ENGINEER AND THE BUILDING DEPARTMENT <br />OFFICIAL FOR REVIEW, PRIOR TO FABRICATION. <br />14. OPTIONS, IF PROVIDED HEREIN, ARE FOR THE CONTRACTOR'S <br />CONVENIENCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CHANGE <br />NECESSARY, SHALL COORDINATE ALL DETAILS, SHALL OBTAIN ALL REQUIRED <br />APPROVALS, AND PAY ALL COSTS INCIDENT THERETO. <br />15. NON-STRUCTURAL FRAMING REQUIREMENTS ARE NOT SPECIFIED ON <br />STRUCTURAL DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR ANY <br />ADDITIONAL FRAMING REQUIRED. <br />16. MATERIAL TESTS AND STAGES OF BUILDING CONSTRUCTION INSPECTIONS <br />AS REQUIRED BY THE LOCAL CODE ARE TO BE STRICTLY ADHERED TO. THIS <br />INCLUDES, BUT IS NOT LIMITED TO, CONCRETE BLOCK, REINFORCING STEEL, <br />ELECTRICAL, MECHANICAL, PLUMBING, ETC. <br />17. SPECIFICATIONS TO PRECEDE PLANS AND DIMENSIONS. DIMENSIONS TO <br />PRECEDE PLANS. <br />18. THE CONTRACTOR SHALL INFORM THE ENGINEER IN WRITING ANY <br />DISCPREPANCIES OR OMISSIONS NOTED ON THE DRAWINGS OR IN THE <br />SPECIFICATIONS OR OF ANY VARIATIONS NEEDED IN ORDER TO CONFORM <br />TO BUILDING CODES, RULES AND REGULATIONS. <br />19. ALL DECK DRAINAGE SHALL BE COLLECTED AND CONDUCTED TO AN <br />APPROVED LOCATION IN A NON-EROSIVE MANNER. <br />20. ALL ROOF AND PAD DRAINAGE SHALL BE CONDUCTED TO THE STREET IN AN <br />ACCEPTABLE MANNER. <br />21. NO SUBSTITUTION SHALL BE MADE FOR ANY MATERIAL, ARTICLE, METHOD <br />OR PROCESS HEREIN SPECIFIED OR SHOWN ON PLANS UNLESS APPROVED <br />BY THE OWNER AND THE ARCHITECT/ENGINEER. <br />GENERAL NOTES <br />1. ALL LUMBER SHALL BE STRESS GRADE DOUGLAS FIR LARCH, U.N.O. <br />2. ALL WOOD IN DIRECT CONTACT WITH THE GROUND, MASONRY OR <br />CONCRETE SHALL BE TREATED WITH PRESERVATIVE, OR SHALL BE DECAY <br />RESISTANT WOOD AS PRESCRIBED IN DIVISION 31 (WOOD PRESERVATIVE). <br />3. ALL WALLS SHALL BE BOLTED TO FOUNDATION (CONCRETE OR CONCRETE <br />BLOCK) WITH 5 8" DIAMETER ANCHOR BOLTS EMBEDDED 7" INTO FOOTING <br />WITHIN 12" OF THE ENDS OF EACH WALL PANEL AND NOT MORE THAN 6'-O" <br />O.C. AND HAVE MINIMUM TWO BOLTS PER PIECE OF SILL PLATE AND ONE <br />LOCATED WITHIN 12" AND NOT LESS THAN 7 BOLT DIAMETER OR 4-3/8" OF <br />EACH END OF EACH SILL PLATE WITH 3"X3"X14" PLATE WASHERS EXCEPT AS <br />CALLED OUT FOR SHEAR WALLS. <br />4. ALL NAILING SHALL BE DONE IN ACCORDANCE WITH THE MINIMUM <br />REQUIREMENTS (TABLE 2304.9.1) LOCAL BUILDING CODE, EXCEPT AS <br />OTHERWISE SHOWN, AND SHALL BE DONE WITH COMMON WIRE NAILS <br />UNLESS OTHER TYPE OF NAIL IS ALLOWED BY THE L.A.C.B.C. <br />5. EXTERIOR WALLS AND BEARING PARTITIONS SHALL BE FRAMED OF 2X4 <br />STUDS @ 16" O.C. WHEN SUPPORTING LOADS FROM ROOF AND TWO OR <br />MORE FLOORS ABOVE UNLESS OTHERWISE NOTED ON DRAWING. AT <br />STAGGERED STUD WALLS USE 2X4 @ 16" EACH SIDE TYPICAL @ ALL <br />FLOORS UNLESS NOTED OTHERWISE ON PLANS. <br />6. EVERY WOOD STUD BEARING WALL OR BEARING PARTITION SHALL BE <br />BRACED AT EACH END OR AS NEAR AS POSSIBLE, AND AT LEAST EVERY 25 <br />FEET OF ITS LENGTH. THE TYPE OF BRACING SHALL MEET THE CODE <br />REQUIREMENTS FOR THIS PURPOSE. <br />7. FLOOR JOISTS SHALL BE DOUBLED UNDER PARTITIONS RUNNING PARALLEL <br />TO THE JOISTS. USE DOUBLE STUDS OR 4X4 POSTS UNDER DOUBLE JOISTS <br />OR 4X BEAMS, U.N.O. ON FRAMING PLANS. <br />8. BOLTS SHALL BE UNFINISHED BOLTS CONFORMING TO ASTM A-307. <br />9. PLYWOOD SHALL BE INTERIOR TYPE WITH EXTERIOR GLUE CONFORMING <br />TO APA 32/16 "PS I-95" OF GRADE CALLED FOR BELOW. LAID WITH FACE <br />GRAIN PERPENDICULAR TO SUPPORTS. USE COMMON NAILS ONLY UNLESS <br />OTHERWISE APPROVED BY THE STRUCTURAL ENGINEER AND LOCAL <br />BUILDING OFFICIAL. <br />A. ROOF SHEATHING SHALL BE: 12" THICK PLYWOOD, STRUCT. I, NAILS <br />WITH 10d NAILS @ 6" O.C. AT ALL DIAPHRAGM AND WALL BOUNDARIES. <br />CONTINUOUS PANEL EDGES ARE NOT BLOCKED, 10d NAILS @ 6" O.C. AT <br />PLYWOOD PANEL EDGES AND 10d NAILS @ 12" O.C. TO INTERMEDIATE <br />SUPPORTS. <br />B. FLOOR SHEATHING SHALL BE 5 8" PLYWOOD, (T&G), NAILED WITH 10d <br />NAILS @ 6" O.C. AT PLYWOOD PANEL EDGES AND 10d NAILS @ 10" O.C. <br />TO INTERMEDIATE SUPPORTS. <br />C. PLYWOOD SHEATHING SHALL BE INSPECTED AND APPROVED BY <br />BUILDING INSPECTOR PRIOR TO COVERING WITH FLOOR OR ROOF <br />MATERIAL. <br />D. SOLID BLOCKING AT EDGES REQUIRED FOR PLYWOOD ONLY WHERE <br />CALLED FOR ON DRAWING. <br />11. CUTTING, NOTCHING OR DRILLING OF BEAMS OR JOISTS TO BE PERMITTED <br />ONLY AS DETAILED OR APPROVED BY THE ENGINEER. <br />12. FRAMING HARDWARE SPECIFIED TO BE MANUFACTURED BY "SIMPSON <br />STRONG TIE COMPANY, INC." WITH NAIL SIZE AND NUMBER AS SPECIFIED IN <br />THE SIMPSON CATALOG LATEST EDITION, U.N.O. <br />2.RAFTER TIES SPACED 48" O.C. MAX ON CENTERS ARE REQUIRED <br />IMMEDIATELY ABOVE CEILING JOISTS WHICH ARE NOT PARALLEL TO THE <br />RAFTERS. <br />3. PROVIDE 2X BLOCKING UNDER PARTITIONS PERPENDICULAR TO FLOOR <br />JOISTS. <br />4. ROOF PURLINS MUST NOT BE SMALLER THAN RAFTERS THEY SUPPORT. <br />THE MAXIMUM SPAN FOR 2X4/2X6 ROOF PURLINS ARE 4'/6'. PROVIDE STRUTS <br />NOT SMALLER THAN 2X4 WITH AN UNBRACED LENGTH NOT OVER 8' AND <br />NOT FLATTER THAN 45 DEGREES FROM THE HORIZONTAL TO BEARING <br />WALLS AND PARTITIONS. <br />5. INTERIOR WALLS USED FOR SHEAR WALLS SHALL BE BALLOON FRAMED TO <br />RAFTERS. <br />6. ALL BEAMS TO BE SUPPORTED WITH SAME FULL WIDTH BEARING, U.N.O. <br />7. STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ETC, UNLESS <br />SPECIFICALLY DETAILED. <br />8. BEARING WALL STUDS CANNOT BE NOTCHED MORE THAN 25% OF THEIR <br />WIDTH. BORED HOLES CANNOT HAVE A DIAMETER GREATER THAN 40% OF <br />THE STUD WIDTH. <br />9. AT FLOOR LEVELS USE SOLID BLOCKING BELOW TRIMMERS AND POSTS <br />FROM BEARING HEADERS AND BEAMS. <br />10. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE <br />GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR <br />SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. <br />1. FINISHED EXCAVATIONS FOR FOUNDATIONS SHALL BE NEAT AND TRUE <br />TO LINE, WITH ALL LOOSE MATERIAL AND STANDING WATER REMOVED <br />FROM EXCAVATIONS. <br />2. BEFORE ANY CONCRETE IS PLACED, EXCAVATIONS SHALL BE <br />CHECKED AND APPROVED BY A QUALIFIED SOILS ENGINEER TO <br />INSURE COMPLIANCE WITH THE REPORT REQUIREMENTS. <br />3. ALL FILL MATERIAL IS TO BE APPROVED BY THE SOILS ENGINEER AND <br />IS TO BE COMPACTED TO 90% OF MAXIMUM DENSITY ASTM METHOD <br />D-1557 (OR MORE AS DIRECTED). INSPECTION IS REQUIRED DURING <br />FILL AND COMPACTION. <br />4. NOTIFY THE STRUCTURAL ENGINEER OF ANY UNUSUAL SOIL <br />CONDITIONS THAT ARE IN VARIANCE WITH THE DATA HEREIN CITED. <br />5. STEP FOOTINGS WHERE REQUIRED AT A RATE OF 1 VERTICAL TO 2 <br />HORIZONTAL, WITH A MAXIMUM VERTICAL STEP OF 2'-0". <br />6. SLAB ON GRADE SHALL BE PLACED ON FIRM, MOISTENED COMPACT <br />EARTH (BELOW SUBBASE) AND SHALL HAVE CONSTRUCTION JOINTS <br />SPACED NO FURTHER APART THAN 25 FEET IN EACH DIRECTION, <br />UNLESS OTHERWISE NOTED. <br />7. ALL WOOD BEARING WALL, SHEAR WALL AND EXTERIOR WALL <br />FOUNDATION PLATES OR SILLS SHALL BE BOLTED TO THE <br />FOUNDATION OR FOUNDATION WALL WITH NOT LESS THAN 5 8" <br />DIAMETER X 12" ANCHOR BOLTS WITH 3" X 3" X 0.229" SQUARE PLATE, <br />EMBEDDED AT LEAST 9" INTO CONCRETE AND SPACED NOT MORE <br />THAN 4'-0" APART UNLESS OTHERWISE NOTED. THERE SHALL BE A <br />MINIMUM OF TWO BOLTS PER PIECE WITH ONE BOLT LOCATION WITHIN <br />12" OF EACH END OF EACH PIECE. <br />8. DIMENSIONS ARE NOT FURNISHED TO SIMPSON HD, LCB, CB OR PA <br />TYPE HOLDOWNS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR'S <br />SUPERINTENDENT, THE FRAMING CONTRACTOR AND THE CONCRETE <br />CONTRACTOR TO LOCATE THESE ANCHORS IN THE EXACT LOCATION. <br />9. ALL SIMPSON PA, HD, LCB AND CB HOLDOWNS TO BE FASTENED TO <br />MIN 4X4 POST. <br />10. ALL ISOLATED POSTS AND BEAMS TO HAVE SIMPSON PB'S AND PC'S <br />MINIMUM UNLESS OTHERWISE NOTED. <br />11. SIMPSON PA, HD, LCB AND CB ANCHORS TO BE TIED IN PLACE PRIOR <br />TO CALLING FOR INSPECTION. <br />12. SLABS SHALL HAVE MINIMUM THICKNESS OF 4 INCHES AND <br />REINFORCEMENT OF #4 @ 16" OC EACH WAY OR APPROVED EQUAL, <br />PLACED AT THE CENTER OF THE SLAB. FOR MOISTURE SENSITIVE <br />SLABS, A VAPOR BARRIER MEMBRANE COVERED WITH A 2" MINIMUM <br />OF CLEAN SAND SHOULD BE PLACED BELOW THE SLAB. <br />13. LAG BOLTS: PROVIDE LEAD HOLE 70% OF THREADED SHANK DIAMETER <br />AND FULL DIAMETER FOR SMOOTH SHANK PORTION. SOAP, PARAFFIN, <br />OR OTHER APPROVED LUBRICANT SHALL BE USED ON THREADS. <br />INSTALLATION SHALL BE BY SCREWING NOT HAMMERING. CARE SHALL <br />BE TAKEN TO AVOID OVER TORQUING BOLT. <br />14. PLATE WASHERS ARE REQUIRED FOR ALL HOLDOWNS. <br />15. ALL HOLDOWN ANCHOR NUTS SHALL BE TIGHTENED JUST PRIOR TO <br />COVERING OF THE WALL FRAMING. <br />16. THE FOUNDATION SILLS SHALL BE PRESSURE TREATED OR <br />FOUNDATION GRADE REDWOOD. <br />17. FOUNDATIONS FOR ALL BUILDINGS WHERE THE SURFACE OF THE <br />GROUND SLOPES MORE THAN 1 UNIT VERTICAL IN 10 UNITS <br />HORIZONTAL (10% SLOPE) SHALL BE LEVEL OR SHALL BE STEPPED SO <br />THAT BOTH TOP AND BOTTOM OF SUCH FOUNDATION ARE LEVEL. <br />18. EXPANSIVE SOIL REQUIREMENTS: <br />IF SOIL IS FOUND TO BE EXPANSIVE, THE FOOTINGS MUST MEET THE <br />FOLLOWING MINIMUM REQUIREMENTS: <br />A. DEPTH OF FOOTINGS BELOW THE NATURAL AND FINISH GRADES <br />SHALL NOT BE LESS THAN 24" FOR EXTERIOR AND 24" FOR INTERIOR <br />FOOTINGS. <br />B. EXTERIOR WALLS AND INTERIOR BEARING WALLS SHALL BE <br />SUPPORTED ON CONTINUOUS FOOTINGS. <br />C. FOOTINGS SHALL BE REINFORCED WITH A MINIMUM FOUR 12" <br />DIAMETER DEFORMED REINFORCING BARS. TWO BARS SHALL BE <br />PLACED 4 INCHES OF THE BOTTOM OF THE FOOTING AND TWO BARS <br />WITHIN 4 INCHES OF THE TOP OF THE FOOTINGS. <br />D. THE SOIL BELOW AN INTERIOR CONCRETE SLAB SHALL BE <br />SATURATED WITH MOISTURE TO A DEPTH OF 18" PRIOR TO PLACING OF <br />CONCRETE. <br />E. CONCRETE SLABS ON GRADE ON EXPANSIVE SOIL OR COMPACTED <br />FILL SHALL BE PLACED ON A 4" FILL OF COARSE AGGREGATE OR ON A <br />2" SAND BED COVERED MOISTURE BARRIER MEMBRANE. THE SLABS <br />SHALL BE AT LEAST 4" THICK AND SHALL BE REINFORCED WITH #4 <br />BARS SPACED AT INTERVALS NOT EXCEEDING 16" EACH WAY. <br />19. HOLDOWN CONNECTOR BOLT HOLES SHALL NOT BE MORE THAN 116" <br />OVERSIZED AT THE CONNECTOR OF THE HOLDOWN TO THE POST. <br />FOUNDATION NOTES STRUCTURAL WOOD NOTES <br />GENERAL NOTES AND SPECIFICATIONS <br />ME <br />C <br />H <br />. <br /> <br />U <br />N <br />I <br />T <br />AT <br />T <br />A <br />C <br />H <br />E <br />M <br />E <br />N <br />T <br />: <br />21 <br />5 <br /> <br />W <br />. <br /> <br />4 <br />t <br />h <br />. <br /> <br />S <br />t <br />. <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Sheet # <br />Sheet title <br />Date : <br />Project #: <br />Phase: <br />10-10-2024 <br />24-186 <br />2nd submittal <br />#Date <br />Revisions: <br />1 <br />2 <br />3 <br />4 <br />St <br />r <br />u <br />c <br />t <br />u <br />r <br />a <br />l <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br />+ <br />D <br />e <br />s <br />i <br />g <br />n <br />5 <br />10 PsfCEILING LIVE LOAD: <br />SEISMIC DESIGN CATEGORY: <br />SEISMIC SITE CLASS: <br />SPECTRAL RESPONSE ACCELERATION <br />SPECTRAL RESPONSE ACCELERATION <br />AT SHORT PERIODS <br />AT 1-SECOND PERIOD <br />SEISMIC VALUES (FOR AREAS A) <br />MAPPED SPECTRAL RESPONSE ACCELERATION <br />MAPPED SPECTRAL RESPONSE ACCELERATION <br />AT SHORT PERIODS <br />AT 1-SECOND PERIOD <br />a.1 <br />b. <br />d. <br />e. <br />c. <br />IMPORTANCE FACTOR 1 <br />a.2 RISK CATEGORY II <br />SDC="D" <br />"D" <br />SDS=1.17g <br />SD1=0.8g <br />SS=1.48g <br />S1=0.51g <br />LATITUDE: <br />LONGITUDE: <br />33.7482 °N <br />-117.8692 °W <br />DESIGN PARAMETERS <br />2022 CBC : CALIFORNIA BUILDING CODE <br />7-16 ASCE : MINIMUM DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES <br />2021 IBC : INTERNATIONAL BUILDING CODE <br />DEAD & LIVE LOADS <br />7.0 PsfCEILING DEAD LOAD: <br />215 W 4th St <br />1/22/2025