PLUMBING SPECIFICATIONS: <br />1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL GOVERNING CODES AND <br />REQUIREMENTS. NOTHING IN THIS SPECIFICATION SHALL BE CONSTRUED TO PERMIT <br />DEVIATION FROM THE REQUIREMENTS OF THE GOVERNING CODES. <br />2.THE PLUMBING CONTRACTOR SHALL VISIT THE SITE AND SHALL VERITY ALL EXISTING <br />CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING ANY WORK. ALL DISCREPANCIES <br />SHALL BE REPORTED TO ARCHITECT IMMEDIATELY UPON DISCOVERY. <br />3.AFTER THE CONTRACT HAS BEEN AWARDED THE OWNER SHALL NOT BE HELD <br />RESPONSIBLE FOR INADEQUATE FIELD INVESTIGATION OR IMPROPER EVALUATION OF <br />THE CONTRACT DOCUMENTS WHICH RESULT IN ADDITIONAL COST. <br />4.THE PLUMBING CONTRACTOR SHALL FURNISH ALL MATERIAL AND EQUIPMENT AND <br />PERFORM ALL LABOR TO INSTALL PLUMBING SYSTEMS COMPLETELY, AS INDICATED ON <br />THE DRAWINGS, AS REQUIRED BY CODE, AND AS SPECIFIED HEREIN. THE WORK INCLUDES <br />FINAL CONNECTIONS TO EQUIPMENT AND FIXTURES PROVIDED BY OTHERS. <br />5.THE PLUMBING CONTRACTOR SHALL OBTAIN PERMIT, LICENSES, AND PAY FOR ALL FEES <br />REQUIRED TO PERFORM THE CONTRACT WORK AND SHALL PROVIDE TO OWNER <br />ACCEPTABLE RECORD COPIES. <br />6.ALL MATERIAL AND EQUIPMENT SHALL BE NEW, FULL WEIGHT, AND OF THE BEST QUALITY <br />WITH THE SAME BRAND OR MANUFACTURER USED FOR EACH CLASS OD MATERIAL OR <br />EQUIPMENT. MATERIAL SHALL BE INSTALLED IN A NEAT AND PROPER MANNER BY <br />COMPETENT,SKILLED SPECIALISTS. <br />7.THE PLUMBING CONTRACTOR SHALL PROVIDE ALL FIXTURES UNLESS OTHERWISE NOTED <br />AND SHALL COORDINATE WITH THE KITCHEN EQUIPMENT CONTRACTOR. THE PLUMBING <br />CONTRACTOR SHALL MAKE ALL ROUGH-IN AND FINAL CONNECTIONS, AND PROVIDE ALL <br />INTERCONNECTING PARTS INCLUDING VALVES, PRESSURE REGULATORS, TEMPERATURE <br />AND PRESSURE SAFETY RELIEF VALES, TRAPS, STRAINERS AND SUPPLY SHUT-OFF <br />VALVES. <br />8.REFER TO ROUGH-IN DRAWINGS FURNISHED BY THE KITCHEN EQUIPMENT CONTRACTOR <br />FOR EXACT LOCATION OF WATER PIPING SUPPLIES AND DRAIN LOCATIONS TO SERVE <br />FOOD SERVICE EQUIPMENT. <br />9.COORDINATE WITH THE WORK OF OTHER SECTIONS AND TRADES, WITH EQUIPMENT <br />FURNISHED BY OTHERS, AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF <br />THE PROJECT SITE. <br />10. THE PLUMBING CONTRACTOR SHALL PROVIDE FLOOR DRAINS A SHOWN ON THE <br />DRAWINGS AND AS REQUIRED BY CODE, AND SHALL SET FLOOR DRAINS TO ALLOW <br />POSITIVE DRAINAGE IN A 6'-0" DIA. CIRCULAR PATTERN. <br />11.THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL FLOOR SINKS AS SHOWN ON <br />THE DRAWINGS AND AS REQUIRED BY CODE. FLOOR SINKS SHALL BE SET TO ALLOW <br />POSITIVE DRAINAGE AND SHALL BE ACCESSIBLE FOR CLEANING, FOR EXAMPLE, HALF <br />UNDER EQUIPMENT AND HALF EXPOSED. <br />12.THE PLUMBING CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVES, IF <br />REQUIRED, TO MAINTAIN GENERAL WATER PRESSURE IN KITCHEN AT 50 P.S.L. <br />13.THE HOOD FIRE SUPPRESSION SYSTEM SHALL BE CONNECTED TO THE GAS SUPPLY LINE <br />WITH O VALVE TO AUTOMATICALLY SHUT OFF GAS SUPPLY WHEN ACTIVATED. <br />14.WASTE PIPING: PROVIDE ALL DRAIN, WASTE AND SEWER PIPING WITHIN THE PROJECT <br />SPACE WITH CONNECTION TO THE BASE BUILDING'S EXISTING SANITARY WASTE SYSTEM <br />ON SITE. ALL PIPING BELOW FLOOR SLAB SHALL BE SERVICE WEIGH HUB AND SPIGOT PIPE <br />AND FITTINGS WITH NEOPRENE GASKET JOINTS. ALL PIPING SHALL BE SLOPED UNIFORMLY <br />AT 2% UNLESS OTHERWISE REQUIRED BY EXISTING CONDITIONS. <br />15.VENTS: PROVIDE A COMPLETE SYSTEM OF VENT PIPING, OF SERVICE WEIGHT COST IRON <br />HUBLESS PIPE, CONNECTORS AND FITTINGS, COMBINE THE VENT RISERS IN THE CEILING <br />SPACE AND PROVIDE A VENT THROUGH EXISTING ROOF PER LANDLORD REQUIREMENTS. <br />LOCATE VTR MINIMUM 10" FROM ROOF - TOP UNIT FRESH AIR INTAKE. COORDINATE WITH <br />LANDLORD'S ROOFING CONTRACTOR. <br />16.WATER PIPING: CONNECT TO LANDLORD'S EXISTING VALVED SERVICE WATER PIPING. <br />PROVIDE A NEW DOMESTIC HOT AND COLD WATER PIPING SYSTEM INSIDE THE SPACE AS <br />SHOWN ON THE DRAWINGS, LAY OUT WATER PIPING SO THAT THE ENTIRE SYSTEM CAN BE <br />DRAINED, HOT AND COLD WATER PIPING SHALL BE TYPE "L" COPPER TUBING ASTM B-88' <br />WITH WROUGHT COPPER FITTINGS AND SWEAT CONNECTIONS USING LEAD-FREE <br />SOLDER. PROVIDE 18" TALL AIR CHAMBER AT EACH FIXTURE STOP, OR WATER HAMMER <br />ARRESTERS AT CONTRACTOR'S OPTION. FLUSH THE WATER PIPING CLEAR OF DEBRIS AND <br />CLEAN THE AERATORS AND STRAINERS AT THE TERMINATION OF THE INSTALLATION. <br />17.NATURAL GAS PIPING: INSIDE THE BUILDING ABOVE GRADE SHALL BE SCHEDULE 40 BLACK <br />STEEL PIPE ASTM A-53 AND MALLEABLE IRON SCREWED FITTINGS WITH SCREWED <br />JOINTS. FITTINGS WITH SCREWED JOINTS. PROVIDE ALL UNIONS, SHUT OFF VALVES AND <br />DRIP LEGS REQUIRED BY NFPA-54 AND GOVERNING CODES. PROVIDE ALL TESTS, <br />INSPECTIONS, HANGERS AND APPURTENANCES REQUIRED FOR A COMPLETE AND <br />OPERATING SYSTEM. INSTALL PER LANDLORD'S SPECIAL REQUIREMENTS. <br />18.CLEANOUTS: PROVIDE CLEANOUTS AT THE END OF EACH HORIZONTAL RUN, AND AT THE <br />BASE OF ALL VERTICAL WASTE PIPES, AND/OR AS REQUIRED BY CODE. CLEANOUTS SHALL <br />BE THE SAME SIZE AS THE PIPES THEY SERVE, UP TO 4" SIZE <br />19. PIPE INSULATION: INSULATE ALL COLD WATER PIPING WITH 1/2" AND HOT WATER PIPING <br />WITH 1", PREFORMED FIBERGLASS WITH ALL- SERVICE JACKET WITH VAPOR BARRIER <br />(BY-CT, OC, JM,PPG OR KINAUF) AT CONTRACTOR'S OPTION, FLEXIBLE UNICELLULAR <br />ELECTROMETRIC CLOSET-CELL INSULATION (BY ARMSTRONG, BUBATEX OR EQUAL) WITH <br />A MAXIMUM FLAME SPREAD ROOTING OF 25 AND SMOKE DEVELOPED RATING OF 50 MAY <br />BE USED. <br />20. ACCESS PANELS: TO BE PROVIDED IN CEILINGS OR WALLS WHERE CONCEALED CONTROL <br />DEVICES ARE LOCATED. WHERE ACCESS FOR ADJUSTMENT AND MAINTENANCE IS <br />POSSIBLE THROUGH LAY - IN CEILINGS, ACCESS PANELS ARE NOT REQUIRED. <br />21. SHUT - OFF VALVES WITH UNIONS SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR <br />ON THE SERVICE TO FIXTURES AND FOOD SERVICE ITEMS AS REQUIRED TO FACILITATE <br />ISOLATION FOR REPAIR OR REPLACEMENT AND AS SHOWN ON THE DRAWINGS. <br />22.DRAIN PIPING SHALL BE TYPE M COPPER WITH WROUGHT COPPER FITTINGS. <br />23.THE PLUMBING CONTRACTOR SHALL: THOROUGHLY CLEAN ITEMS BEFORE <br />INSTALLATIONS. CAP PIPE OPENINGS TO EXCLUDE DIRT UNTIL FIXTURES ARE INSTALLED <br />AND FINAL CONNECTIONS HAVE BEEN MODE. PROCEED AS RAPIDLY AS CONSTRUCTION <br />WILL PERMIT. SET FIXTURES LEVEL AND IN PROPER ALIGNMENT, INSTALL SUPPLIES IN <br />PROPER ALIGNMENT WITH FIXTURES, PER MANUFACTURE'S ROUGH-IN DIMENSIONS. <br />INSTALL SILICONE SEALANT BETWEEN FIXTURES AND ADJACENT MATERIAL FOR SANITARY <br />JOIN. REPAIR ANY DAMAGE DONE TO EXISTING FEATURES AND RESTORE TO ORIGINAL <br />CONDITIONS. PROVIDE CLEAN CONDITIONS AT TERMINATION OF WORK. <br />24.ALL WATER PIPING SHALL BE INSTALLED TO PREVENT UNUSUAL NOISES FROM THE FLOW <br />OF WATER. FURNISH AND INSTALL APPROVED ISOLATION MATERIAL (1" THICK STRIP OF <br />WAFFLE PATTERN HAIR FELT ) TO ISOLATE ALL PIPING FROM DIRECT CONTACT WITH <br />BUILDING, CONDUIT, ETC. <br />25. PROVIDE SEPARATE STOPS FOR EACH INDIVIDUAL HOT AND COLD WATER CONNECTION <br />IN ADDITION TO ANY FAUCETS OR VALVES THAT ARE PART OF THE FIXTURE TRIM. EACH <br />GAS OUTLET SHALL BE PROVIDED WITH A SHUT OFF COCK. PROVIDE GATE VALVES AND <br />UNIONS FOR WATER HEATER. <br />26.ALL PIPING SHALL BE TESTED IN ACCORDANCE WITH APPLICABLE CODES. TEST WATER <br />SYSTEM UNDER 150 PSIG HYDROSTATIC PRESSURE FOR FOUR HOURS MINIMUM. WHEN <br />TESTING INDICATES MATERIALS OR WORKMANSHIP ARE DEFICIENT, REPLACE OR REPAIR <br />AS REQUIRED, AND REPEAT TEST TILL STANDARDS ARE ACHIEVED. <br />27.THE PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE, DEPTH, AND <br />AVAILABILITY OF ALL UTILITIES CONCERNED . <br />28. THE PROPRIETARY NAME AND/ OR MODEL NOTED ON THE DRAWINGS IS THE MAKE AND/ <br />OR MODEL USED IN THE DESIGN, MODEL CHANGES MAY AFFECT THE DESIGN. <br />29.THE PLUMBING CONTRACTOR SHALL MAKE ABSOLUTELY. WATERTIGHT ANY OPENING <br />THROUGH WATERPROOFED CONSTRUCTION CAUSED BY THE PENETRATION OF <br />DUCTWORK OR PIPING. ALL WORK SHALL BE IN A MANNER APPROVED BY THE ARCHITECT <br />AND THE LANDLORD. <br />30. THE PLUMBING CONTRACTOR SHALL RUN ALL INDIRECT WASTE LINES FROM KITCHEN <br />EQUIPMENT AND CONDENSATE DRAIN LINES FROM AIR CONDITIONING UNITS. INSULATES <br />LINES WITH JOHNS -- MANVILLE 1 <br />2' AERO- TUBE OR EQUAL TO PREVENT CONDENSATE DRIP. <br />31. ALL EXPOSED DOMESTIC PIPES SHALL HAVE MARKERS WITH DIRECTION OF FLOW <br />ARROWS AND COLOR CODES WITH CLEARLY PRINTED LEGEND IDENTIFYING THE <br />CONTENTS OF THE PIPS. ALL VALVES SHALL HAVE BRASS TAG IDENTIFYING THE <br />APPROPRIATE SERVICE. <br />32. WATER HEATER SHALL BE GLASS LINED STEEL TANK WITH A STORAGE VOLUME OF <br />______________ GALLONS AND RATED INPUT OF _______________BTU PER HOUR. WATER <br />HEATER SHALL WRAPPED WITH INSULATION WITH A THERMAL RESISTANCE OF R-12. <br />FURNISH AND INSTALL A FLUE VENT SYSTEM COMPLETE WITH VENT PIPE, SPACERS, <br />FLASHING, COUNTERFLASHING, COP, ETC. AND IN ACCORDANCE WITH LANDLORD <br />REQUIREMENTS. <br />33.GREASE INTERCEPTOR SHALL BE MODEL_________________________.20 GPM FLOW AND 40 <br />LB. GREASE CAPACITY, WITH LIFT OUT SEDIMENT BUCKET AND ALUMINUM COVER. <br />INTERCEPTORS SHALL BE SET ON THE FLOOR UNLESS CONDITIONS ALLOW FOR BELOW <br />FLOOR INSTALLATION. <br />REMARKSSERVICE <br />ROUGH-INS <br />WASTE VENT H.W.C.W <br />MARK DESCRIPTION <br />WC-1 <br />ADA <br />ADA FLOOR MOUNTED PRESSURE ASSIST FLUSH TANK <br />TOILET,AMERICAN STANDARD MODEL 2467.100, WHITE <br />VITREROUS CHINA, ELONGATED BOWL, 1.1 GPF, WITH <br />SEAT AND ANGLE STOP VALVE. <br />- <br />L-1 <br />WALL MOUNT LAVATORY, WHITE VITREROUS CHINA, <br />KHOLER MODEL K-2861, 4" CENTERSET, WITH SENSOR <br />ACTIVATED FAUCET SLOAN MODEL EFT-600, 0.5 GPM <br />SET TIMER AT 12 SECONDS ENSURING 0.10 GALLONS <br />PER CYCLE. INSTALLWITH KOHLER DRAIN MODEL <br />K-7129-A A INSTALL THERMOSTACTIC MIXING VALVE <br />EQUAL TO WATTS MODEL L111 TO LIMIT THE FAUCET <br />OUTLET TEMPERATURE TO MAX 110 DEGREES. ( ASEE <br />1070APPROVED. <br />FD-1 FLOOR DRAIN BY ZURN MODEL Z415B, DURA COATED <br />CAST IRON WITH BOTTOM OUTLET, COMBINATION <br />INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE <br />COLLAR WITH SEEPAGE SLOTS AND 'TYPE B' POLISHED <br />BRONZED. 6" LIGHT DUTY STRAINER. <br />- <br />FS-1 JR SMITH MODEL 3440, CAST IRON BODY AND GRATE <br />WITH ENAMELED PORCELAIN COATING <br />- <br />PLUMBING FIXTURE SCHEDULE <br />WATER <br />WASTE <br />ROOF DRAIN <br />GREASE DRAIN <br />VENT <br />INDIRECT WASTE <br />CONDENSATE DRAIN <br />GAS <br />INSIDE <br />BEL. GRADE. <br />ABV. FLR. <br />BEL. FLR. <br />ABV. FLR. <br />BEL. FLR. <br />ABV. FLR. <br />BEL. FLR. <br />ABV. FLR. <br />BEL. FLR. <br />INSIDE. <br />OUTSIDE. <br />INSIDE. <br />OUTSIDE. <br />INSIDE. <br />OUTSIDE. <br />OUTSIDE BEL GRADE. <br />LOCATION <br />MATERIALS <br />TY <br />P <br />E <br /> <br />' <br />L <br />' <br /> <br />C <br />O <br />P <br />P <br />E <br />R <br />TY <br />P <br />E <br /> <br />' <br />M <br />' <br /> <br />C <br />O <br />P <br />P <br />E <br />R <br />NO <br />- <br />H <br />U <br />B <br /> <br />C <br />A <br />S <br />T <br />IR <br />O <br />N <br />SC <br />H <br />. <br /> <br />4 <br />0 <br /> <br />B <br />L <br />A <br />C <br />K <br />. <br />ST <br />E <br />E <br />L <br />SC <br />H <br />. <br /> <br />4 <br />0 <br /> <br />G <br />A <br />L <br />V <br />. <br />ST <br />E <br />E <br />L <br />PO <br />L <br />Y <br />E <br />T <br />H <br />Y <br />L <br />E <br />N <br />E <br />SC <br />H <br />. <br /> <br />4 <br />0 <br /> <br />P <br />V <br />C <br />AB <br />S <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br /> <br />4 <br />0 <br />TY <br />P <br />E <br /> <br />K <br /> <br />C <br />O <br />P <br />P <br />E <br />R <br />SC <br />H <br />E <br />D <br />U <br />L <br />E <br /> <br />8 <br />0 <br /> <br />P <br />V <br />C <br />SC <br />H <br />E <br />D <br />U <br />L <br />E <br /> <br />4 <br />0 <br /> <br />P <br />V <br />C <br />LEAD FREE SOLDER JONTS <br />SCHEDULE 80 PVC EXTERNAL TO BUILDING IF PERMITED <br />NO-HUB CAST IRON WHER SOIL ANALYSIS <br />ALLOWS TO USE IT. <br />NO HUB WITH SS BAND FOR CAST IRON. <br />ABS SCHEDULE 40 WHERE PERMITED <br />NO HUB WITH SS BAND FOR CAST IRON <br />NO HUB WITH SS BAND FOR CAST IRON <br />NO HUB WITH SS BAND FOR CAST IRON <br />95-5 SOLDERED FITTINGS <br />USE DWV COPPER FOR PLUMBING FIXTURE IN <br />KITCHENS <br />95-5 SOLDERED FITTINGS <br />95-5 SOLDERED FITTINGS <br />SCH.40 THREADED FITTINGS <br />SCH.40 THREADED FITTINGS <br />SOLVENT WELD FITTINGS <br />PIPE SCHEDULE AND MATERIAL <br />4"2"12" <br />2"2"12" <br />2"2" <br />2"2" <br />12" <br />MOP <br />SINK <br />STAINLESS STEEL FLOOR MOUNT MOP BASIN SINK , <br />GSW MODEL SE2024 FM <br />12"2"3"12" <br />PREP. <br />SINK <br />SINK, ONE COMPARTMENT, 39-1/8"W X 24"D X 45"H, <br />18-GAUGE STAINLESS STEEL CONSTRUCTION, 18" X 18" <br />X 12" DEEP COMPARTMENT, 18" DRAINBOARD ON LEFT, <br />11-1/2"H BACKSPLASH, 8" OC SPLASH MOUNT FAUCET <br />HOLES, INCLUDES STRAINER WITH 3-5/8" DIA. OPENING, <br />STAINLESS STEEL LEGS & CROSSBRACING, ETL <br />12"2"2"12" <br />3 COMP. <br />SINK <br />GSW MODEL SH24243D STAINLESS STEEL LEGS WITH <br />CROSS BRACING EXTRA WELDED UNDER TUBS FOR <br />LONGEVITY THREE-TUB SINK WITH LEFT & RIGHT DRAIN <br />BOARDS 8" WALL MOUNTED FAUCET HOLES <br />STRAINER INCLUDED STRAINER OPENING DIAMETER <br />3-5/8" FAUCET NOT INCLUDED NSF CERTIFIED ETL <br />CERTIFIED <br />3 4"2"3"3 4" <br />HAND <br />SINK <br />GSW MODEL HS-0810S HAND SINK, WALL MOUNT, 10"W X <br />8" FRONT-TO-BACK X 5" DEEP BOWL, INCLUDES: NO LEAD <br />FAUCET & STRAINER, WITH WELDED SPLASH GUARDS, <br />SS304 STAINLESS STEEL, ETL <br />12"2"2"12" <br />CLOTH <br />WASHER <br />LG WM6998HBA, VENTLESS WASHER/DRYER COMBO LG <br />WASHCOMBO™ ALL-IN-ONE 5.0 CU. FT. MEGA CAPACITY <br />WITH INVERTER HEATPUMP™ TECHNOLOGY AND DIRECT <br />DRIVE MOTOR <br />12"2"2"12" <br />P-0.1 <br />THIS DRAWING, SPECIFICATIONS AND <br />IDEAS, DESIGNS THEREBY ARE AND SHALL <br />REMAIN THE PROPERTY OF IG DRAFTING & <br />DESIGN AND NO PART THEREOF SHALL BE <br />COPIED DISCLOSED TO OTHERS OR USED <br />IN CONNECTION WITH ANY WORK OR <br />PROJECT FOR WHICH THERE HAVE BEEN <br />PREPARED AND DEVELOPED, WITHOUT THE <br />WRITTEN CONSENT OF IG DRAFTING & <br />DESIGN, VISUAL CONTACT WITH THESE <br />DRAWINGS SHALL CONSTITUTE EVIDENCE <br />OF ACCEPTANCE OF THESE RESTRICTIONS. <br />DO <br />N <br /> <br />C <br />H <br />U <br />R <br />R <br />O <br />S <br />1 <br />2 <br />3 <br />4 <br />2 <br />2 <br />215 W 4th St <br />1/22/2025