Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)111 @ 2 1/2" 2109 (2.25") Passed (5%) -- 1.0 D + 1.0 L (All Spans) <br />Shear (lbs)98 @ 9"990 Passed (10%) 1.00 1.0 D + 1.0 L (All Spans) <br />Moment (Ft-lbs)298 @ 5' 8"848 Passed (35%) 1.00 1.0 D + 1.0 L (All Spans) <br />Live Load Defl. (in)0.128 @ 5' 8"0.364 Passed (L/999+) -- 1.0 D + 1.0 L (All Spans) <br />Total Load Defl. (in)0.192 @ 5' 8"0.546 Passed (L/682) -- 1.0 D + 1.0 L (All Spans) <br />TJ-Pro™ Rating N/A N/A N/A -- N/A <br />Member Length : 11' 1 1/2" <br />System : Floor <br />Member Type : Joist <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />• Deflection criteria: LL (L/360) and TL (L/240). <br />• Allowed moment does not reflect the adjustment for the beam stability factor. <br />• A 15% increase in the moment capacity has been added to account for repetitive member usage. <br />• Applicable calculations are based on NDS. <br />• No composite action between deck and joist was considered in analysis. <br />• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Floor Live Factored Accessories <br />1 - Stud wall - DF 3.50" 2.25" 1.50" 38 76 113 1 1/4" Rim Board <br />2 - Stud wall - DF 3.50" 2.25" 1.50" 38 76 113 1 1/4" Rim Board <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)11' 2" o/c <br />Bottom Edge (Lu)11' 2" o/c <br />Dead Floor Live <br />Vertical Load Location (Side)Spacing (0.90)(1.00)Comments <br />1 - Uniform (PSF)0 to 11' 4"16"5.0 10.0 Ceiling Load <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />Level, 2x6 @ 16" O.C. C.J Check <br />1 piece(s) 2 x 6 DF No.2 @ 16" OC <br />ForteWEB Software Operator Job Notes 7/12/2024 5:52:42 AM UTC <br />Trang Ho <br />LT Designs <br />(714) 213-1608 <br />onetrang10@gmail.com <br />ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 <br />File Name: 2217 W Civic Center Dr <br />Page 3 / 12 <br />5 <br />2217 W Civic Center Dr <br />Unit# 29/9/2024