Laserfiche WebLink
T.O.PLATE <br />10'-0" <br />T.O.SLAB <br />0'-0" <br />T.O.RIDGE 2 <br />APPX.14'-8 1/2" <br />32 8 <br />1 <br />STUCCO WALL (N) <br />TO MATCH (E)4 4 <br />4 <br />GRADE <br />-0'-8" <br />BLDG HEIGHT <br />15 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />(N) WINDOW <br />(N) WINDOW (N) WINDOW <br />EAST ELEVATION WALL OPENINGS IN WALL LOCATED WITHIN THE 5-FT <br />OF PROPERTY LINE SHALL BE LIMITED TO 25% OF THE WALL <br />TOTAL THE WALL OF AREA : 465 SF <br />TOTAL WINDOW & DOORS OF AREA: 83 SF <br />THE WALL OF AREA DOES NOT INSLUDE WINDOWS & DOORS: 382 SF <br />APPROXIMATELY 82% OVER 25% IS OKAY <br />1 1 <br />T.O.PLATE <br />10'-0" <br />T.O.SLAB <br />0'-0" <br />T.O.RIDGE 2 <br />APPX.14'-8 1/2" <br />3 2 78 <br />1 <br />STUCCO WALL (N) <br />TO MATCH (E) <br />(N) EGRESS WINDOW <br />4 <br />7.81 SF <br />11 32 <br />" <br /> <br />4 <br />8 <br />" <br />60" <br />4 66.110 <br />GRADE <br />-0'-8" <br />BLDG HEIGHT <br />15 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />1 <br />T.O.PLATE <br />10'-0" <br />T.O.SLAB <br />0'-0" <br />T.O.RIDGE 2 <br />APPX.14'-8 1/2" <br />3 28 <br />1 <br />STUCCO WALL (N) <br />TO MATCH (E) <br />11(N) EGRESS WINDOW <br />4 <br />7.81 SF <br />60" <br />32 <br />" <br /> <br />4 <br />8 <br />" <br />(N) WINDOW <br />4 <br />GRADE <br />-0'-8" <br />BL <br />D <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />15 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />4 <br />(N) WINDOW <br />NORTH ELEVATION WALL OPENINGS IN WALL LOCATED WITHIN THE 5-FT <br />OF PROPERTY LINE SHALL BE LIMITED TO 25% OF THE WALL <br />TOTAL THE WALL OF AREA : 362 SF <br />TOTAL WINDOWS & DOORS OF AREA : 41 SF <br />THE WALL OF AREA DOES NOT INSLUDE WINDOWS: 321 SF <br />APPROXIMAELY 88% OVER 25% IS OKAY <br />1 <br />T.O.PLATE <br />10'-0" <br />T.O.SLAB <br />0'-0" <br />T.O.RIDGE 2 <br />APPX.14'-8 1/2" <br />3 27 <br />11 <br />1 <br />STUCCO WALL (N) <br />TO MATCH (E) <br />1 <br />STUCCO WALL (N) <br />TO MATCH (E) <br />7 <br />(N) SIDING TO MATCH (E)(N) SIDING TO MATCH (E)(N) SIDING TO MATCH (E) <br />1 <br />STUCCO WALL (N) <br />TO MATCH (E) <br />GRADE <br />-0'-8" <br />BL <br />D <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />15 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />G C <br />R-30 <br />R-13 <br />(N) ATTIC FAU <br />E <br />J <br />F <br />H <br />R-15 <br />4 <br />12 <br />F F <br />D <br />F <br />T.O.PLATE <br />10'-0" <br />T.O.SLAB <br />0'-0" <br />T.O.RIDGE 2 <br />APPX.14'-8 1/2" <br />4 <br />12 <br />CRRC PRODUCT <br />ID 0610-0018 <br />10 <br />' <br />- <br />0 <br />" <br />B <br />GRADE <br />-0'-8" <br />BL <br />D <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />15 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />1 <br />B G C <br />(N) ATTIC FAU <br />E <br />J <br />F <br />H <br />R-15 <br />4 <br />12 <br />T.O.PLATE <br />10'-0" <br />T.O.SLAB <br />0'-0" <br />T.O.RIDGE 2 <br />APPX.14'-8 1/2" <br />4 <br />12 <br />F <br />BLDG HEIGHT <br />15 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />D <br />3' <br />- <br />4 <br />" <br />7' <br />- <br />4 <br />" <br />F FR-30 <br />R-13 <br />8 <br />KITCHENDINING ROOMLIVING ROOMBATH 2 <br />GRADE <br />-0'-8" <br />1 <br />2' <br />SCALE : 1/4" = 1'-0" <br />0 4'8' <br />ATTIC VENTILATION SECTION KEYNOTES <br />(N) 2x RIDGE BOARD PER STRUCT. <br />(N) 2x ROOF RAFTER PER STRUCT. <br />(N) 2x CEILING JOISTS PER STRUCT. <br />(N) CONCRETE SLAB PER STRUCT. <br />(N) FOOTING PER STRUCT. <br />(N) 2x STUD WALL PER STRUCT. <br />A (N) ATTIC INSULATION PER T-24 <br />(N) ROOF R.R. INSULATION PER T-24 <br />(N) WALL INSULATION PER T-24 <br />WEEP SCREED FOR STUCCO, <br />2" ABOVE PAVED AREAS <br />GUTTER / DOWNSPOUT. SPLASH <br />BLOCK ON GRADE <br />SOFFIT VENT <br />B <br />C <br />D <br />E <br />F <br />G <br />H <br />J <br />ELEVATION KEYNOTES <br />(N) STUCCO, PAINT AND MATERIAL TO <br />MATCH EXISTING <br />(N) ASPHALT SHINGLES (ESR-1389) OVER <br />2-15# FELT PAPER OVER 1/2" PLYWOOD <br />TO MATCH MAIN HOUSE <br />(N) FASCIA & TRIMMING - PAINT TO <br />MATCH MAIN HOUSE <br />(N) 2 1/2" VINYL MOLDING TRIM FOR ALL <br />WINDOWS TO MATCH MAIN HOUSE <br />1 (N) CONCRETE LANDING <br />(N) ELEC. PANEL 200AMP <br />(N) ELEC. SUBPANEL 125AMP <br />(N) DORMER, LOUVER, OR <br />SOFFIT VENTS <br />(N) SOLAR PANELS <br />(N) STUCCO WRAPPED 4X <br />WOOD POST <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />K <br />L <br />1-HR RATED WALL. <br />1/2" TYPE C OR 5/8" TYPE X <br />GYPSUM BOARD ON THE <br />GARAGE SIDE FULL HEIGHT TO <br />THE GARAGE ROOF SHEATHING <br />MINVERTER AND METERING <br />EQUIPMENT PROPOSED <br />LOCATION. PROVIDE <br />PATHWAY FOR ROUTING <br />FROM THE SOLAR ZONE TO <br />THE MAIN SERVICE PANEL. <br />1-INCH CONDUIT LINE SHALL <br />BE PROVIDED. <br />10 <br />11 <br />DEPTH OF EAVE TO MATCH <br />MAIN DWELLING, TYP. <br />N <br />(N) AC UNIT <br />12 (N) WATER HEATER PER T-24 <br />1 ) ROOF COVERING MATERIAL FOR NEW CONSTRUCTION <br />SHALL BE MINIMUM CLASS A IN ACCORDANCE WITH UL 790 <br />OR ASTM E108. (R902.1 CRC) <br />TYPE: COOL SHINGLES <br />MANUFACTURE: OWNENS CORNING (EQUAL OR SIMILAR) <br />ICC-ES AC438 <br />ASTM E108/UL 790 (CLASS A FIRE RESISTANCE) <br />2) THE TOP OF THE EXTERIOR FOUNDATION SHALL <br />EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER <br />A MINIMUM OF 12” PLUS 2%. (CRC R403.1.7.3, CBC 1808.7.4) <br />CONSTRUCTION NOTESLEGEND <br />4 <br />12 INDICATES 4:12 ROOF SLOPE <br />ATTIC AREA: 998 SF / USE BALANCE METHOD : <br />NET VENT AREA REQUIRE : 998 SF / 300 x 144 SQ.IN. = 480 SQ.IN. <br />1/2 OF VENT AREA WILL BE PLACED AT HIGH PART OF ROOF <br />(EXHAUST VENT) <br />1/2 OF VENT AREA WILL BE PLACED AT LOW PART OF ROOF <br />(INTAKE VENT) <br />480/2 = 240 SQ.IN <br />LOW: USE 2 UNITS O'HAGIN VENT (72 SQ.IN / UNIT) = 144 SQ.IN. <br />HIGH: USE 2 UNITS O'HAGIN VENT (72 SQ.IN / UNIT) = 144 SQ.IN. <br />TOTAL PROVIDED = 288 SQ.IN. <br />ATTIC VENTS ARE REQUIRED TO BE PROTECTED WITH <br />CORROSION RESISTANT WIRE CLOTH SCREENING, HARDWARE <br />CLOTH, PERFORATED VINYL OR SIMILAR MATERIAL. THE <br />OPENINGS SHALL BE A MINIMUM 1/16” AND SHALL NOT EXCEED <br />¼”. [§R806.1 CRC] <br />WHEN THERE ARE INSULATION AT THE ROOF, A MINIMUM 1” <br />CLEARANCE SHALL BE PROVIDED BETWEEN THE ATTIC <br />INSULATION AND THE ROOF SHEATHING WHERE EAVE OR <br />CORNICE VENTS ARE INSTALLED. [§R806.3 CRC] <br />6.1 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />22 <br />1 <br />7 <br /> <br />W <br /> <br />C <br />I <br />V <br />I <br />C <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />D <br />R <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />M <br />A <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br />22 <br />1 <br />7 <br />W <br /> <br />C <br />I <br />V <br />I <br />C <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />D <br />R <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DETACHED ADU: <br />2 BEDROOMS, <br />2 BATHROOMS, <br />LIVING, KITCHEN, <br />DINING, AND <br />LAUNDRY <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />PROJECT CONTACT <br />OWNERSHIP <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING <br />CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING <br />OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS <br />AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY <br />KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF <br />CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS <br />SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO <br />THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE <br />OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN <br />CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />A.06 <br />ACCESSORY <br />DWELLING UNIT <br />ELEVATIONS & <br />SECTIONS <br />1/4" = 1'-0"2EAST ELEVATION -ADU <br />1/4" = 1'-0"1WEST ELEVATION -ADU <br />1/4" = 1'-0"5NORTH ELEVATION -ADU <br />1/4" = 1'-0"6SOUTH ELEVATION -ADU <br />1/4" = 1'-0"4BUILDING SECTION 1/4" = 1'-0"3BUILDING SECTION <br /> 1 07/20/2024 PLAN CHECK SUBMITTAL <br />11 <br />2217 W Civic Center Dr <br />Unit# 29/9/2024