Laserfiche WebLink
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E <br />Project Name:2217 W Civic Center Dr - ADU Calculation Date/Time:2024-02-08T14:45:39-08:00 (Page 2 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:2217 W Civic Center Dr - T24.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-02-08   14:46:09 <br />ENERGY DESIGN RATINGS <br />Energy Design Ratings Compliance Margins <br />Source Energy <br />(EDR1) <br />Efficiency1 EDR <br />(EDR2efficiency) <br />Total2 EDR <br />(EDR2total) <br />Source Energy <br />(EDR1) <br />Efficiency1 EDR <br />(EDR2efficiency) <br />Total2 EDR <br />(EDR2total) <br />Standard Design 37.9 39.4 28.2 <br />Proposed Design 37.6 38.9 27.9 0.3 0.5 0.3 <br />RESULT3: PASS <br />1Efficiency EDR includes improvements like a better building envelope and more efficient equipment <br />2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries <br />3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded <br />•Standard Design PV Capacity: 2.38 kWdc <br />•PV System resized to 2.38 kWdc (a factor of 2.381) to achieve 'Standard Design PV' PV scaling <br />2217 W Civic Center Dr <br />Unit# 29/9/2024