Laserfiche WebLink
DOOR PER SCHEDULE <br />WOOD STUD FRAME <br />CEM. PLASTER EXT. FINISH <br />3/8" SEALANT O/ BACKER ROD <br />PLYWD. SHEATHING WHERE <br />OCCURS, S.S.D. <br />PLASTER J MOLD <br />5/8" TYPE X GYPSUM SHEATHING <br />S.A.M.F., 12" STRIP, 9" ON <br />WALL FACE, 3" INTO R.O. & <br />OVER PAN FLASHING <br />W.R.B. <br />S.A.M.F., 12" STRIP <br />2 X 4 STUD WALL WITH ONE <br />LAYER OF GYPSUM BOARD <br />ON EACH SIDE <br />STANDARD PROFILE WOOD CASING; <br />PRIMED AND PAINTED, RE: SPEC <br />PREHUNG WOOD DOOR AND <br />FRAME ASSEMBLY <br />WOOD FRAMING PER <br />STRUCTURAL <br />RE: STRUCT. FOR SHEAR <br />WALL REQUIREMENTS <br />4 3/4" <br />STUCCO SYSTEM ON LATH, INSTALL <br />PER MFR. RECOMMENDATIONS <br />MFR. FACTORY FINISHED WINDOW AS SCHEDULED <br />INTERIOR FINISH <br />SELF ADHERED FLASHING OVER WINDOW FIN <br />RE: TYPICAL WINDOW FLASHING DETAIL <br />BACKER ROD AND SEALANT <br />(2) LAYERS LAPPED WEATHER RESISTANT <br />BARRIER ON EXTERIOR GRADE SHEATHING <br />J-MOLD <br />SELF ADHERED FLASHING UNDER NAILING <br />FIN, WRAP BOTH CORNERS 6" MIN., LAP OVER <br />BACK DAM <br />VINYL WINDOW WITH NAILING <br />FLANGES ON FOUR SIDES <br />STUCCO SYSTEM ON LATH, INSTALL <br />PER MFR. RECOMMENDATIONS <br />PROVIDE SEALANT AT SIDES & BOTTOM OF <br />WINDOW; PROVIDE BACKER ROD AS NEEDED <br />(TYPICAL) <br />J MOLD <br />(2) LAYERS LAPPED WEATHER RESISTANT <br />BARRIER ON EXTERIOR GRADE SHEATHING <br />BACK DAM AT SILL, EXTEND END DAM <br />UP JAMB 6" <br />BACKER ROD AND SEALANT AS REQ'D. <br />VINYL WINDOW WITH NAILING <br />FLANGES ON FOUR SIDES <br />BACKER ROD & SEALANT <br />J MOLD <br />FIBER CEMENT BOARD TRIM <br />STUCCO SYSTEM ON LATH, INSTALL <br />PER MFR. RECOMMENDATIONS <br />(2) LAYERS LAPPED WEATHER RESISTANT <br />BARRIER ON EXTERIOR GRADE SHEATHING <br />SELF ADHERED FLASHING UNDER NAILING <br />FIN, WRAP BOTH CORNERS 6" MIN., LAP OVER <br />BACK DAM <br />BACK DAM AT SILL OR CONT. SEALANT <br />AT BACK OF WINDOW FRAME, EXTEND <br />END DAM UP JAMB 6" <br />STUCCO SYSTEM ON LATH, INSTALL PER <br />MFR. RECOMMENDATIONS <br />VINYL WINDOW WITH NAILING <br />FLANGES ON FOUR SIDES; DO NOT <br />NAIL FLANGE AT HEADER <br />(2) LAYERS LAPPED WEATHER BARRIER ON <br />EXTERIOR GRADE SHEATHING, LAP FIRST LAYER <br />OVER METAL FLASHING, LAP SECOND LAYER INTO <br />WEEP SCREED OR PER MFR. <br />WEEP SCREED <br />GALVANIZED METAL FLASHING W/ DRIP <br />EDGE, SET IN BED OF SEALANT, EXTEND UP <br />WALL 6" <br />BACKER ROD AND SEALANT <br />INTERIOR FINISH <br />SELF ADHERED WATERPROOF WRB SYSTEMS <br />TAPE <br />FLEX. FLASHING OVER TOP NAILING FLANGE WITH <br />BOTTOM EDGE INTO A CONTINUOUS, FULL <br />CONTACT BED OF SEALANT <br />RE: ELEVATIONS FOR <br />EXTERIOR MATERIAL <br />INTERIOR EXTERIOR <br />SLOPE TO DRAIN <br />SOLID SURFACE SILL <br />TILE ON MORTAR BED <br />WATER RESISTANT GYP. <br />WRAP TILE INTO WINDOW <br />JAMB WHERE TILE <br />CONTINUES PAST SILL <br />WEATHER RESISTANT BARRIER ON <br />EXTERIOR GRADE SHEATHING <br />BACK DAM AT SILL, EXTEND UP JAMB 6" <br />SELF ADHERED FLASHING UNDER <br />NAILING FIN, WRAP BOTH CORNERS 6" <br />MIN., LAP OVER BACK DAM <br />VINYL WINDOW WITH NAILING FLANGES <br />ON FOUR SIDES <br />PROVIDE SEALANT AT SIDES & BOTTOM <br />OF WINDOW; PROVIDE BACKER ROD AS <br />NEEDED (TYPICAL) <br />BACKER ROD AND <br />SEALANT, AS REQ'D. <br />GARAGE <br />1 <br />GA FILE NO. WP3660 <br />GENERIC ONE HOUR RATED WALL <br />CONSTRUCTION: <br />1. ONE LAYER 1/2 IN. TYPE 'X' GYPSUM WALLBOARD APPLIED AT RIGHT ANGLE TO EACH SIDE OF 2x WOOD STUDS 16 IN. O.C. <br />WITH 2-1/4 IN. TYPE S OR W DRYWALL SCREWS 7 IN. O.C. VERTICAL JOINTS STAGGERED 16 IN. O.C. ON OPPOSITE SIDES. <br />HORIZONTAL JOINTS STAGGERED 24 IN. O.C. ON OPPOSITE SIDES. <br />UNIT <br />3" = 1'-0"3DOOR JAMB AT EXT WALL <br />3" = 1'-0"1DOOR HEAD / JAMB -INT. 2x4 STUD WALL <br />3" = 1'-0"6WOOD -WINDOW JAMB -STUCCO <br />3" = 1'-0"5WOOD -WINDOW SILL -STUCCO3" = 1'-0"8WOOD -WINDOW SILL -STUCCO W/ TRIM <br />3" = 1'-0"4WOOD -WINDOW HEAD -STUCCO <br />3" = 1'-0"9WOOD -WINDOW SILL -SHOWER -INTERIOR <br />2" = 1'7WOOD -1-HR WALL -INTERIOR TO GARAGE <br />SEISMIC STRAPING OF WATER HEATER <br />STRAPPING SHALL BE AT A POINT WITHIN THE UPPER 1/3 AND THE LOWER 1/3 OF THE <br />WATER HEATER'S VERTICAL DIMENSIONS. AT THE LOWER POINT, A MINIMUM DISTANCE <br />OF FOUR (4) INCHES SHALL BE MAINTAINED ABOVE THE CONTROLS TO THE STRAP. <br />OTHER METHODS AND LOCATION MAY BE ACCEPTABLE, CHECK WITH THE BUILDING & <br />SAFETY DIVISION. <br />AC CONDENSER MOUNTING PAD <br />EGRESS OPENINGS & FLOOD OPENING N.T.S.2 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />22 <br />1 <br />7 <br /> <br />W <br /> <br />C <br />I <br />V <br />I <br />C <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />D <br />R <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />M <br />A <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br />22 <br />1 <br />7 <br />W <br /> <br />C <br />I <br />V <br />I <br />C <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />D <br />R <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DETACHED ADU: <br />2 BEDROOMS, <br />2 BATHROOMS, <br />LIVING, KITCHEN, <br />DINING, AND <br />LAUNDRY <br /> 01/09/2024 PLANNING REVIEW <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />PROJECT CONTACT <br />OWNERSHIP <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING <br />CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING <br />OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS <br />AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY <br />KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF <br />CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS <br />SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO <br />THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE <br />OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN <br />CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />A.08 <br />ARCHITECTURAL <br />DETAILS <br />2217 W Civic Center Dr <br />Unit# 29/9/2024