My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2112 S Woodland Pl - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Woodland Pl
>
2112 S Woodland Pl
>
2112 S Woodland Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:01:59 PM
Creation date
6/1/2025 12:01:44 PM
Metadata
Fields
Template:
Plan
Permit Number
20179849
101115397
Full Address
2112 S Woodland Pl
Document Relationships
101115397 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Woodland Pl\2112 S Woodland Pl
20179849 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Woodland Pl\2112 S Woodland Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SITE NOTES: <br />A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA <br />REGULATION. <br />THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS <br />A UTILITY INTERACTIVE SYSTEM WHIT NO STORAGE BATTERIES. <br />THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, <br />MECHANICAL, OR BUILDING ROOF VENTS. <br />PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND <br />PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION <br />CEC 110.26 <br />ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN <br />ACCORDANCE WITH THIS CODE AND APPROVED MANUFACTURERS <br />INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE <br />BUILDING OR STRUCTURE. <br />EQUIPMENT LOCATIONS: <br />ALL EQUIPMENT SHALL MEET MINIMUM SETBAKC AS REQUIRED BY <br />CEC 110.26. <br />WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR <br />EXPECTED OPERATING TEMERATURES AS SPECIFIED BY CEC 690.31 (A),(C) <br />AND CEC TABLES 310.15 (B)(2)(C). <br />JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES <br />ACCORDING TO CEC 690.34 <br />ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER <br />IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. <br />ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL <br />ACCORDING TO CEC APPLICABLE CODES. <br />ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR <br />OUTDOOR USAGE WHEN APPROPRIATE. <br />STRUCTURAL NOTES: <br />RACKING SYSTEM AND PV ARRAY WILL BE INSTALLED ACCORDING TO <br />CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A <br />DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST BE ALSO EXTEND A <br />MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, <br />ACCORDING TO RAIL MANUFACTURERS INSTRUCTIONS. <br />JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. <br />IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED AND SEALED PER LOCAL <br />REQUIREMENTS. <br />ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND <br />SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. <br />ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE <br />SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. <br />WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE <br />STAGGERED AMONGST THE ROOF FRAMING MEMBERS. <br />EQUIPMENT LOCATIONS: <br />ALL EQUIPMENT SHALL MEET MINIMUM SETBAKC AS REQUIRED BY <br />CEC 110.26. <br />WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR <br />EXPECTED OPERATING TEMERATURES AS SPECIFIED BY CEC 690.31 (A),(C) <br />AND CEC TABLES 310.15 (B)(2)(C). <br />JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES <br />ACCORDING TO CEC 690.34 <br />ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER <br />IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. <br />ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL <br />ACCORDING TO CEC APPLICABLE CODES. <br />ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR <br />OUTDOOR USAGE WHEN APPROPRIATE. <br />WIRING AND CONDUIT NOTES: <br />ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. <br />CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE <br />REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. <br />CONDUCTOR SIZED ACCORDING TO CEC 690.8, CEC 690.7. <br />VOLTAGE DROP LIMITED TO 1.5% <br />DC WIREING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIREING <br />SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE <br />WIREING CLIPS. <br />AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: <br />PHASE A OR L1- BLACK <br />PAHSE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE <br />PHASE C OR L3- BLUE, YELLOR, ORANGE**, OR OTHER CONVENTION <br />NEUTRAL- WHITE OR GRAY <br />IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE <br />TO BE MARKED ORANGE [CEC 110.15]. <br />grounding notes: <br />grounding system components shall be listed for their purpose, <br />and grounding devices exposed to the elements shall be rated for <br />such use. <br />pv equipment shall be grounded according to cec 690.43 and <br />minimum cec table 250.122 <br />mental parts of modules frames, modules racking, and enclosures <br />considered groined in accord with 250.134 and 250.136(a). <br />equipment grounding conductors shall be sized according to cec <br />690.45 and micoinverters manufacturers instructions. <br />each modules will be grounded using weeb grounding clips as <br />shown in manufacturer documentation and approved by the ahj. if <br />weebs are not used, module grounding lugs must be installed at <br />the specified grounding lugs holes per the manufacturers <br />installation requirements. <br />the grounding connection to a module shall be arranged such <br />that the removal of a module does not interrupt a grounding <br />conductor to another module. <br />grounding and bonding conductors, if insulated, shall be colored <br />green or marked green if #4 awg or larger [cec 250.119]. <br />the grounding electrode system complies with cec 690.47 and cec <br />250.50 through 250.106. if existing system is inaccessible, or <br />inadequate, a grounding electrode system provided according to <br />cec 250, cec 690.47 and ahj. <br />grounding-fault detection shall comply with cec 690.41(b)(1) and (2) to <br />reduce fire hazards. <br />disconnection and over-current protection notes: <br />disconnecting switches shall be wired such that when the switch <br />is opened the conductors remaining energized are connected to <br />the terminals marked "lineside" (typically the upper terminals). <br />disconnects to be accessible to qualified utility personnel, be <br />lockable, and be a visible-break switch. <br />pv system circuits installed on or in buildings shall include a <br />rapid shutdown function to reduce shock hazard for emergency <br />responders in accordance with 690.12(a) through (d). <br />all ocpd ratings and types specified according to cec 690.8, 690.9, <br />and 240. <br />microinverter branches connected to a single breaker or <br />grouped fuses in accordance with cec 110.3(b). <br />if required by ahj, system will included arc-fault circuit protection <br />according to cec 690.11 and ul 1699b. <br />interconnection notes: <br />load-side interconnection shall be in accordance with [cec <br />705.12(b)] <br />the sum of the utility ocpd and inverter continuous output may <br />not exceed 120% of busbar rating [cec 705.12(d)(2)(3)]. <br />the sum of 125 percent of the power source(s) output circuit <br />current and the rating of the over current device protecting the <br />busbar shall not exceed 120 percent of the ampacity of the <br />busbar, pv dedicated back feed breakers must be located opposite <br />end of the bus from the utility source ocpd [cec 705.12(b)(2)(3)]. <br />at multiple electric power sources output combiner panel, total <br />rating of all over current devices shall not exceed ampacity of <br />busbar, however, the combined over current device may be <br />excluded according to cec 705.12(b)(2)(3)(c). <br />feeder tap interconnection (load side) according to cec 705.12 <br />(b)(2)(1). <br />supply side tap interconnection according to cec 705.12 (a) with <br />service entrance conductors in accordance with cec 230.42 <br />backfeeding breaker for electric power sources output is exempt <br />from additional fastening [cec 705.12(b)(5). <br />PLANSET-2 <br />SITE INFORMATION <br />drawn by: <br />sheet name: <br />REVISION: <br />sheet number: <br />site notes <br />PS-2 <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC CEC <br />CEC CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />CEC <br />AHJ:SANTA ANA CITY <br />BUILDING CODE:2022 CBC <br />ELECTRICAL CODE:2022 CEC <br />FIRE CODE:2022 CBC <br />RESIDENTIAL <br />CODE:2022 CRC <br />ELISABETH LE GUIN <br />2212 SOUTH WOODLAND PLACE <br />SANTA ANA <br />CALIFORNIA <br />92707 <br />EE <br />1099198 <br />CONTRACTOR LICENSE <br />NUMBER <br />CONFIDENTIAL - THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT SOLID STATE ELECTRIC LLC, <br />NOR SHALL IT BE DISCLOSED IN <br />WHOLE OR IN PART TO OTHERS <br />OUTSIDE RECIPIENT <br />ORGANIZATIONS, EXCEPT IN <br />CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE <br />EQUIPMENT, WITHOUT THE WRITTEN <br />PERMISSION OF SOLID STATE <br />ELECTRIC LLC. <br />FLEX ENERGY ELECTRIC <br />LLC <br />472 E 1750 N SUIT 200, <br />VINEYARD, UT <br />84059 <br />04/25/2023 <br />3 <br />2112 S Woodland <br />Pl06/20/23
The URL can be used to link to this page
Your browser does not support the video tag.