My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2303 S Bristol St #A - 101117496, 20181548, 30146629 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
2303 S Bristol St Unit# A
>
2303 S Bristol St #A - 101117496, 20181548, 30146629 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 9:39:16 AM
Creation date
6/1/2025 12:01:45 PM
Metadata
Fields
Template:
Plan
Permit Number
20181548
30146629
101117496
Full Address
2303 S Bristol St Unit# A
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3 PETERS CANYON RD. STE 110 <br />IRVINE, CA 92606 <br />D <br />G <br />ESI <br />N <br />| <br />ARCHITECTURE <br />H E S T I A A T E L I E R <br />SHEET NUMBER: <br />SHEET TITLE: <br />SCALE: AS SHOWN <br />STORE #: <br />PROJECT #: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />C 2020 STARBUCKS COFFEE COMPANY <br />R <br />ISSUE DATE: <br />2401 UTAH AVENUE SOUTH <br />SEATTLE, WASHINGTON 98134 <br />(206) 318-1575 <br />THESE DRAWINGS AND THE PROJECT MANUAL <br />ARE CONFIDENTIAL AND SHALL REMAIN THE <br />SOLE PROPERTY OF STARBUCKS <br />CORPORATION, WHICH IS THE OWNER OF THE <br />COPYRIGHT IN THIS WORK. THEY SHALL NOT <br />BE REPRODUCED (IN WHOLE OR IN PART), <br />SHARED WITH THIRD PARTIES OR USED IN ANY <br />MANNER ON OTHER PROJECTS OR <br />EXTENSIONS TO THIS PROJECT WITHOUT THE <br />PRIOR WRITTEN CONSENT OF STARBUCKS <br />CORPORATION. THESE DRAWINGS AND <br />SPECIFICATIONS ARE INTENDED TO EXPRESS <br />DESIGN INTENT FOR A PROTOTYPICAL <br />STARBUCKS STORE (WHICH IS SUBJECT TO <br />CHANGE AT ANYTIME) AND DO NOT REFLECT <br />ACTUAL SITE CONDITIONS. NEITHER PARTY <br />SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br />THE OTHER (EXCEPT STATED ABOVE) UNTIL A <br />WRITTEN AGREEMENT IS FULLY EXECUTED BY <br />BOTH PARTIES. <br />STARBUCKS R <br />DESIGN MANAGER: <br />PRODUCTION DESIGNER: <br />CHECKED BY: <br />STARBUCKS TEMPLATE VERSION: i2021.04.23 <br />28206-089 <br />09-14-2023 <br />BR <br />I <br />S <br />T <br />O <br />L <br /> <br />& <br /> <br />W <br />A <br />R <br />N <br />E <br />R <br />23 <br />0 <br />3 <br />A <br /> <br />S <br />. <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />. <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />10005 <br /><DESIGN MANAGER> <br /><DESIGNER> <br /><CHECKED BY> <br />2N <br />D <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />1 <br />2 <br />- <br />2 <br />4 <br />- <br />2 <br />0 <br />2 <br />3 <br />Revision Schedule <br />Rev Date By Description <br />A 12/24/2023 PLAN CHECK <br />E500 <br />SINGLE LINE DIAGRAM <br />TO EXISTING <br />UTILITY TRANSFORMER <br />AVAILABLE NOT TO EXCEED <br />42,000A <br />(E) SERVICE ENTRANCE EQUIPMENT <br />400A, 120/208V, 3ΙΈ-4W, 65kAIC <br />U.G.P.S. <br />G <br />N <br />(E) <br />225A <br />3P <br />M <br />(E <br />) <br />REFERENCE NOTES <br />EXISTING PANEL WITH REVISED LOADS. REFER TO PANEL SCHEDULE THIS SHEET. <br />ALL NEW CIRCUIT BREAKERS INSTALLED WITHIN PANELBOARD SHALL MATCH THE <br />HIGHEST EXISTING AIC RATED BREAKERS WITHIN PANELBOARD. INSPECTOR TO <br />VERIFY AT SITE. <br />THE CONTRACTOR SHALL VERIFY THE METER/MAIN OVERCURRENT PROTECTION <br />DEVICE'S MANUFACTURER AND PART NUMBER. <br />CIRCUIT BREAKERS IN ALL DOWNSTREAM PANELS SHALL BE FROM THE SAME <br />MANUFACTURER OF METER/MAIN OVERCURRENT PROTECTION DEVICE. CIRCUIT <br />BREAKER AIC RATING SHALL MATCH OR EXCEED SERVICE AVAILABLE FAULT <br />CURRENT. OTHERWISE, PROVIDE MAIN BREAKER AS SHOWN ON PANEL SCHEDULE <br />PER MANUFACTURER'S SERIES-RATING CHART. <br />THE CONTRACTOR SHALL FIELD VERIFY SERVICE EQUIPMENT'S AVAILABLE FAULT <br />CURRENT BEFORE ISSUING ANY BID. NOTIFY ELECTRICAL ENGINEER IMMEDIATELY <br />IF MAJOR DISCREPANCIES OCCUR <br />THE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE A SERIES <br />COMBINATION RATING WHICH SHALL BE READILY VISIBLE. CONTRACTOR TO AFFIX <br />SERIES COMBINATION RATING LABEL SIMILAR TO AS SHOWN ON DETAIL 3/E500. <br />1 <br />2 <br />3 <br />4 <br />3 <br />2 <br />(E) <br />MAIN <br />HP <br />200A <br />SCALE:NONE2SINGLE LINE DIAGRAMSCALE:NONE1EATON SERIES RATING CHART <br />(E) <br />(E) <br />225 <br />3P <br />(E <br />) <br />(E) <br />MAIN <br />A2 <br />200A <br />(E) <br />MLO <br />A3 <br />225A <br />(E <br />) <br />(E) <br />400A/3P <br />EATON <br />DK <br />2 <br />ITEM DESCRIPTION U/M <br />4 PANEL "HP"66.88 KVA <br />5 PANEL "A2" & "A3"70.62 KVA <br />6 TOTAL 137.50 KVA <br />7 AMPS AT 208V-3PH 381.67 AMPS <br />SCE <br />259000- <br />044818 <br />HAZARDOUS VOLTAGE <br />Series combination system <br />rated 65K amperes <br />May cause injury or <br />equipment damage or <br />failure. <br />Identified replacement <br />components required. <br />CAUTION <br />4 <br />1 <br />4 <br />1 <br />4 <br />1 <br />4 4 <br />A <br />STAMP DATE: 12/24/2023 <br />Email: info@peccusa.com <br />Phone: 909.610.5364 <br />2303 S Bristol St #A - 101117496, <br />20181548, 30146629 <br />2/27/2024
The URL can be used to link to this page
Your browser does not support the video tag.