My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2306 N Spinnaker St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Spinnaker St
>
2306 N Spinnaker St
>
2306 N Spinnaker St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:16 PM
Creation date
6/1/2025 12:01:45 PM
Metadata
Fields
Template:
Plan
Permit Number
20181637
101117603
Full Address
2306 N Spinnaker St
Document Relationships
101117603 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spinnaker St\2306 N Spinnaker St
20181637 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Spinnaker St\2306 N Spinnaker St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SINGLE LINE <br /> DIAGRAM <br />PV SYSTEM <br />AS INDICATED <br />NOVEMBER 15, 2023 <br />ROSA RAMIREZ <br />2306 SPINNAKER ST, <br />SANTA ANA, CA 92706 <br />Clean Energy Solutions Inc. <br />Address: <br />1055 West 7th Street <br />33rd Floor, Los Angeles, <br />CA 90017 <br />Phone Number: <br />(800) 994 1134 <br />Lic# 998787 <br />Class C-10 <br />CONTRACTOR <br />Designed By: Inter Solar Cad <br />www.intersolarcad.com <br />ITEM DESCRIPTION QTY# <br />PV MODULE <br />MAIN SERVICE PANEL <br />MAIN SERVICE PANEL <br />& UTILITY METER <br />BUSBAR RATING <br />BREAKER RATING <br />1 <br />ITEM DESCRIPTION QTY# <br />PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 <br />1 <br />1 <br />1 <br />5 <br />3 <br />1 <br />4 <br />6 <br />MAIN <br />SERVICE <br />PANEL <br />120/240V <br />1P,3W <br />2 <br />EXISTING <br />GROUNDING SYSTEM <br />UTILITY <br />M <br />2 <br />3 <br />5700W <br />INVERTER <br />PEAK PWR TRACKING VOLTAGE <br />INVERTER EFFICIENCY <br />ENCLOSURE : <br />MAXIMUM INPUT CURRENT <br />MAXIMUM OUTPUT CURRENT <br />MAXIMUM INPUT POWER <br />MAXIMUM OUTPUT POWER <br />4 1 <br />380 V <br />99.0 % <br />NEMA 4 <br />27.0 A <br />42.0 A <br />22,000 W <br />10,000 W <br />SOLAREDGE ENERGY HUB SE10000H-USSNBBL14 (240V) <br />SOLAREDGE POWER OPTIMIZER <br />RATED DC INPUT POWER <br />MAXIMUM INPUT VOLTAGE <br />MPPT RANGE <br />MAXIMUM SHORT CIRCUIT CURRENT (Isc) <br />MAXIMUM OUTPUT CURRENT <br />OPTIMIZER WEIGHT <br />MAXIMUM POWER PER STRING <br />5 <br />S440 <br />440W <br />60 Vdc <br />8 to 60 Vdc <br />14.5 Adc <br />15 Adc <br />1.5 Lbs <br />31POWER OPTIMIZER <br />60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, <br />BLADE TYPE, NEMA 3R, 120/240V 16 <br />EXISTING <br />(DOWNSIZED) <br />EXISTING <br />2 <br />1 <br />33 <br />175A <br />200A <br />200A <br />FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 <br />INSTALL 2P <br />60A CB(PV) AT <br />OPPOSITE END <br />OF BUS FROM <br />MAIN FEEDER CB <br />31 <br />Canadian Solar 400W <br />CS6R-400MS-HL <br />Voc = 36.8V <br />Vmp = 30.8V <br />Isc = 13.85A <br />Imp = 12.99A <br />(D)175A <br />String a: (10) Modules, (10) Optimizers <br />17BATTERY BACKUP SYSTEMS <br />SOLAR EDGE ENERGY BANK 10kWh, BAT-10K1P 1BATTERY BACKUP <br />7 (1)#10 AWG (10-12 AWG), 600V insulated <br />(1) #24 AWG (16-24 AWG), 600V insulated or CAT6 <br />1'' EMT TYPE CONDUIT <br />String b: (10) Modules, (10) Optimizers <br />String c: (11) Modules, (11) Optimizers <br />E 1.0 <br />2306 N Spinnaker St - <br />2018163712/18/2023
The URL can be used to link to this page
Your browser does not support the video tag.