My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2314 W San Lorenzo Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
San Lorenzo Ave
>
2314 W San Lorenzo Ave
>
2314 W San Lorenzo Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:02:16 PM
Creation date
6/1/2025 12:01:46 PM
Metadata
Fields
Template:
Plan
Permit Number
20181463
101117407
Full Address
2314 W San Lorenzo Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility <br />(2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required <br />by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. <br />IQ8 and IQ8+ Microinverters <br />INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US <br />Commonly used module pairings1 W 235 – 350 235 – 440 <br />Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 <br />half-cell <br />MPPT voltage range V 27 – 37 29 – 45 <br />Operating range V 25 – 48 25 – 58 <br />Min/max start voltage V 30 / 48 30 / 58 <br />Max input DC voltage V 50 60 <br />Max DC current2 [module Isc] A 15 <br />Overvoltage class DC port II <br />DC port backfeed current mA 0 <br />PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit <br />OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US <br />Peak output power VA 245 300 <br />Max continuous output power VA 240 290 <br />Nominal (L-L) voltage/range3 V 240 / 211 – 264 <br />Max continuous output current A 1.0 1.21 <br />Nominal frequency Hz 60 <br />Extended frequency range Hz 50 – 68 <br />AC short circuit fault current over <br />3 cycles Arms 2 <br />Max units per 20 A (L-L) branch circuit4 16 13 <br />Total harmonic distortion <5% <br />Overvoltage class AC port III <br />AC port backfeed current mA 30 <br />Power factor setting 1.0 <br />Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging <br />Peak efficiency %97.5 97.6 <br />CEC weighted efficiency %97 97 <br />Night-time power consumption mW 60 <br />MECHANICAL DATA <br />Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) <br />Relative humidity range 4% to 100% (condensing) <br />DC Connector type MC4 <br />Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) <br />Weight 1.08 kg (2.38 lbs) <br />Cooling Natural convection – no fans <br />Approved for wet locations Yes <br />Pollution degree PD3 <br />Enclosure Class II double-insulated, corrosion resistant polymeric enclosure <br />Environ. category / UV exposure rating NEMA Type 6 / outdoor <br />COMPLIANCE <br />Certifications <br />CA Rule 21 (UL 1741-SB), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 <br />This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section <br />690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to <br />manufacturer’s instructions. <br />IQ8SP-DS-0002-01-EN-US-2022-08-10 <br />2314 W San Lorenzo <br />Ave11/17/2023
The URL can be used to link to this page
Your browser does not support the video tag.