Laserfiche WebLink
<br /> <br />Certificate: 80019753 <br />Project: 80096975 <br />Master Contract: 600812 <br />Date Issued: 2021-09-29 <br /> <br /> <br />DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 7 <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system <br />voltage of 1500 V dc, model series: FBKxxxD7G (xxx=430-470 in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1000 V dc, model series: FBMxxxMFG (xxx=390-410, in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1000 V dc, model series: FBMxxxMFG-BW (xxx=390-410, in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1000 V dc, model series: FBMxxxMFG-BB (xxx=390-410, in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1500 V dc, model series: FBKxxxMFG (xxx=390-410 in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1500 V dc, model series: FBKxxxMFG-BW (xxx=390-410 in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system <br />voltage of 1500 V dc, model series: FBKxxxDFG (xxx=390-410 in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system <br />voltage of 1500 V dc, model series: FBLxxxBFG (xxx=390-410, in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system <br />voltage of 1500 V dc, model series: FBKxxxD8G (xxx=510-580 in steps of 5), Fuse rating 30A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1000 V dc, model series: F2MxxxEEG (xxx=355-385, in steps of 5), Fuse rating 20A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1000 V dc, model series: F2MxxxEEG-BW (xxx=355-385, in steps of 5), Fuse rating 20A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1000 V dc, model series: F2MxxxEEG-BB (xxx=355-385, in steps of 5), Fuse rating 20A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1500 V dc, model series: F2KxxxEEG (xxx=355-385 in steps of 5), Fuse rating 20A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system <br />voltage of 1500 V dc, model series: F2KxxxEEG-BW (xxx=355-385 in steps of 5), Fuse rating 20A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system <br />voltage of 1500 V dc, model series: F6KxxxC4G (xxx=350-375, in steps of 5), Fuse rating 20A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system <br />voltage of 1500 V dc, model series: F1KxxxC4G (xxx=380-410, in steps of 5), Fuse rating 20A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system <br />voltage of 1500 V dc, model series: F6KxxxC3G (xxx=295-315, in steps of 5), Fuse rating 20A. <br />Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system <br />voltage of 1500 V dc, model series: F1KxxxC3G (xxx=320-335, in steps of 5), Fuse rating 20A. <br /> <br />Notes: <br />1. The electrical characteristics are within ±3 percent of the indicated values of Isc, Voc, and Pmax under <br />standard test conditions (irradiance of 100 mW/cm2, AM 1.5 spectrum, and a cell temperature of 25°C <br />(77°F)), NOCT: 45ºC. <br />2. The operating ambient temperature of these devices may exceed 40 °C at full load for all wire sizes if it is <br />determined suitable in the field use application. <br /> <br /> <br />2314 W San Lorenzo <br />Ave11/17/2023