Laserfiche WebLink
ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check <br />Roof Slope =22 ° <br />Roof Shape Gable <br />Tributary Width s =2.00 ft <br />Tributary Length L =31.00 ft <br />Effective Area A = L ( MAX [ s , L/3] )=100 f 2 <br />Height of Structure h =25 ft <br />Wind Speed V =110 mph <br />Exposure Categor C <br />Building Width B =45 ft <br />Building Length L =45 ft <br />Zone Width a =4.5 ft <br />Elevation Height zg =40 ft <br />Wind Directionality Kd =0.85 <br />Topography Factor Kt =1.00 <br />Ground Elevation Factor Ke =1.00 <br />Velocity Pressure Exposure Coefficient Kz =0.95 <br />Velocity Pressure qz = 0.00256KzKztKdKeV2 =24.85 psf <br />Internal Pressure Coefficient (GCpi)=-0.18 <br />Zone GCp p = qz [(GCp) - (Gcpi)] <br />3 - - <br />3r 1.80 -49.21 <br />3e 1.66 -45.83 <br />2 - - <br />2r 1.66 -45.83 <br />2e - - <br />2n 1.66 -45.83 <br />1 - - <br />1' - - <br />2314 W San Lorenzo <br />Ave11/17/2023